Wear Resistant Silicone Insulated Copper Cable

High flexibility silicone wire designed for electrical installations in demanding environments

Wear-resistant silicone insulated copper cable showing flexible construction

Silicone rubber is a highly sought-after material for insulating cables that need to conduct electricity in harsh environments, including fire-prone applications. These cables offer exceptional performance with long-lasting hot air resistance up to 180-200°C, making them ideal for high-temperature applications. Additionally, they provide excellent flexibility even at low temperatures of -40°C, ensuring reliable performance in extreme conditions.

Technical Specifications
Specification Details
Product Make-up Fine-wire, tin-plated copper conductor
Insulation Silicone-based
Minimum Bending Radius Fixed installation: 6 x outer diameter, Single bend: 3 x cable diameter
Nominal Voltage U0/U: 300/500 V
Test Voltage 2,000 V
Temperature Range -50°C to +180°C (short-term 200°C)
Classification ETIM 5.0 Class-ID: EC000993; ETIM 5.0 Class-Description: single-core cable
Product Features
  • Halogen-free according to IEC 60754-1 (amount of halogen acidic gas)
  • Corrosiveness of combustion gases according to IEC 60754-2 (degree of acidity)
  • Flame-retardant according to IEC 60332-1-2
  • Resistant to a multitude of oils, alcohols, vegetable and animal fats and chemical substances
  • Adequate ventilation must be ensured, since mechanical properties decrease from +100°C in the absence of air
Silicone cable technical specifications and construction details Silicone cable performance characteristics and applications Silicone cable manufacturing process and quality control
Brand LINKE Cross Section (mm²) 0.01-500mm²
Wire Gauge (AWG) [e.g., 24AWG, 28AWG] Conductor Tinned Copper /bare copper, based on client's requirements
Insulation material PVC/TPU/Silicone rubber/PE/PP/XLPE/Nylon/other Jacket Material [PVC/PU/Rubber/Braid/etc.]
Certifications RoHS/REACH/UL/CE/IP68/etc Custom Length [e.g., 1m, 3ft, 5m ±5% tolerance]
Cable Type [Medical/Power/Audio/Coaxial/Electrical/Automotive/Energy storage//etc.] Shielding [Shielded/Unshielded/Braid Shield]
Impedance [e.g., 75Ω (for coaxial cables)] Printing/Logo [Text/Label/Logo, max. 20 characters]
Bend Radius [e.g., ≥5* cable diameter] Current Rating [e.g., 5A]
Voltage Rating [e.g., 30V AC/DC] Connector Material [Gold-plated/Nickel-plated/Brass/etc.]
Connectors [e.g., USB Type-C, 3.5mm Jack, RJ45] Jacket XLPE or PE or PVC RUBBER
Delivery Time 7-14 days after confirming the order Colors [Black/White/Red/Custom Pantone/etc.]
temperature Minus-70℃to 350℃(-70℃ ~ 350℃) Package Roll/box/plate/Custom
Supporting Services custom cable, end to end solutions, including precise cutting, crimping and installation of lugs (specify material,e.g.,copper/nickel plated)
Silicone cable testing and certification documentation

Independent Laboratory • Complete Testing Equipment • Full Quality Control

We test every product by strict standards to ensure superior quality and reliable performance.

No. Test Item Test Condition Test Requirement Test Data Result
1 Structure Inspection 1. Comply with wire size table2. Minimum thickness ≥ 80% of average thickness Comply with wire size table Refer to test record Pass
2 Thermal Shock Wind the sample on an iron rod of specified size, place in an aging oven at specified temperature for 1 hour, cool the sample to room temperature for at least 30 minutes, then observe the sample No cracks on the sample surface No cracks Pass
3 Heat Deformation 1. Measure sample thickness (mark measurement position)2. Place sample and test fixture in aging oven for preheating at specified temperature for 1 hour3. Place sample under pressure column of test fixture for 1 hour4. Re-measure sample thickness at the same position 1. Sample shall not be cracked by pressure column or expose conductor2. Thickness reduction ≤ 50% Refer to test record Pass
4 FT2 Apply a standard flame at a height of 125mm once 1. Flame shall not propagate along its length2. Flame shall not spread to nearby flammable materials Refer to test record Pass
5 Aging 1. Take five sections of 200mm-long sheath2. Place specimens in aging oven at 158℃ for 168 hours3. After taking out specimens, place at room temperature 23±5℃ for 16 hours, then test elongation at break and tensile strength 1. Elongation before aging ≥ 300%, elongation after aging ≥ 80% of that before aging2. Tensile strength before aging > 1.41kg/mm², tensile strength after aging ≥ 80% of that before aging Refer to test record Pass
6 Cold Bend Store sample in low-temperature box at specified temperature for 4 hours, wind sample on iron rod of specified size with specified turns, complete winding within 30 seconds after sample is taken out of low-temperature box No cracks on the sample surface No cracks Pass
7 Conductor Resistance Measure resistance of one-meter core conductor with DC resistance meter At 20℃, resistance of 8AWG ≤ 2.23Ω/km Refer to test record Pass

Linke cable technology (DongGuan) Co. Ltd. concentrate on R&D and

provide professional solutions to the Cable&Wire,especially for the

different industry customers.It contains :

Humanoid robot cable,

AI power cable/data cable,

Semiconductor cable/industrial automatic cable,

Sensor cable,

New energy cable,

Medical beauty wire,

UL wire cable,

Linke Cable has diversified product development capabilities and technical capabilities to support diversified

customer needs. We have obtained the following product authorization:UL 758,CCC,RoHs,REACH,CE; We

have obtained the following quality management system:ISO 9001-2015(All products); ISO 13485

(Medical apparatus and instruments),IATF 16949(Auto industry)

Certifications & Standards
  • UL Standards: UL1007, UL1185, UL1672, UL10070, UL10483, UL1015, UL1569, UL10012, UL10269 (Single conductor, thermoplastic insulation)
  • Additional UL Standards: UL2095, UL2129, UL2468, UL2586, UL2725, UL20233, UL20280, UL20963, UL2103, UL2463, UL2517, UL2587, UL2835, UL20276, UL20549, UL21198, 2104, UL2464, UL2576, UL2661, UL2919, UL20279, UL20886, UL21664
  • Quality Management: ISO9001, ISO13485, TS16949
  • CNR Appliance Wiring Material: Extruded PVC Insulated Single, rated 105ºC, 1000V, Class I, Group A, B, or AB, FT1 and/or FT2
  • Extruded PVC Non-integral Jacketed Cable: rated 105°C, 1000V, Class I, Class or Class I/II, Group A, B, or AB, FT1 and/or FT2
  • Extruded TPU Non-integral Jacketed Cable: rated 80°C, 300V, Class I, Class or Class I/II, Group A, B, or AB, FT1 and/or FT2
Frequently Asked Questions
Are you a manufacturer or trading company?

We are a professional manufacturer. We control your order from beginning to end. Welcome to visit us - we'll provide transportation from Shenzhen.

How can I get a sample to test your quality?

Samples are free for you. New clients are expected to pay for courier costs.

What's your Minimum Order Quantity?

Normally 100m. However, cable is heavy so we recommend ordering suitable quantities to avoid high freight costs. Sea transportation is the best option.

Can I get a discount?

Discounts depend on your quantity. We can offer discounts and cover freight costs for larger orders. Please contact us for details.

Does your company accept OEM production?

Yes, we can print your company name and even customize quality cards to promote your business.

For more information, please feel free to contact us!

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Linke Cable Technology (DongGuan) CO.,LTD
Location No. 1, Yiheng Road, Qinghu Private Park, Qishi Town, Dongguan City, Guangdong Province
Contact Person William Liu

Request A Quote

Please check your email address.
Your message must be at least 20 characters.