The TPAD-100 series is a single-phase high-performance programmable AC power supply
The TPAD-100 series is a single-phase, high-performance programmable AC power supply that offers low-distortion sine wave and arbitrary waveform outputs. With an output frequency of up to 1KHz, built-in high-precision power measurement capabilities, and oscilloscope functions, it provides robust testing and analysis for AC applications.
Main Features and Advantages:
- Utilizes advanced Sinusoidal Pulse Width Modulation (SPWM) technology, offering a lightweight and compact design.
- Supports AC, DC, and AC+DC output modes.
- Capable of controlling the starting/stopping phase angles of the output waveform, as well as adjusting the rate of change for voltage and frequency.
- Incorporates a rich library of waveforms, including Stair, CSIN (Clipped Sine), CF (Crest Factor), SURGE, Dimmer, and other special waveforms, along with 30 IEC-standard compliant distorted waveforms, plus 4 user-defined waveforms.
- The built-in power measurement module uses a high-precision 16-bit ADC with a sampling rate up to 200KHz, accurately capturing peak voltage and current waveforms.
- Supports 6 current measurement ranges and an automatic range, with current and voltage measurement accuracy up to 0.2%, suitable for product standby power consumption testing.
- Supports oscilloscope functions, with multiple trigger modes, and can upload captured waveforms to a computer via USB or Ethernet.
- Can measure Urms, Irms, P, PF, Upk, Ipk, VA, VAR, THD, Is (surge current), and other 20 sets of data, with harmonic analysis capabilities.
- Offers advanced waveform output modes such as LIST, STEP, PULSE, waveform synthesis, and inter-harmonic output.
- Can import specifications and save data through the front panel USB interface.
- Supports communication interfaces with PC such as RS232, RS485, USB, Ethernet, and GPIB.
TPAD-100 Series Specifications:
| Model Numbers | TPAD-110 | TPAD-120 | TPAD-140 | TPAD-160 | |||
| Test Functions: | |||||||
| Output Modes | AC,DC,AC+DC | ||||||
| Programming Features | 9 sets of 8-step gradual changes, steps, sequence tests | ||||||
| Waveform Formats | Standard waveforms, harmonic synthesis, pulse waveforms, start/stop angle setting waveforms | ||||||
| AC Output Specifications: | |||||||
| Output Phases | Single-phase two-wire + PE | ||||||
| Rated Power | 1KVA | 2kVA | 4kVA | 6kVA | |||
| Output Voltage | Low range | 0.0~150.0V(L-N) Nominal voltage: 125V | |||||
| High range | 0.0~300.0V(L-N) Nominal voltage: 250V | ||||||
| Voltage Setting Accuracy | Accuracy: ≤0.4% Resolution: 0.1V Rated | ||||||
| Rated Current | Low range | 8A | 16A | 32A | 48A | ||
| High range | 4A | 8A | 16A | 24A | |||
| Peak Current | Low range | 48A | 96A | 192A | 288A | ||
| High range | 24A | 48A | 96A | 144A | |||
| Output Frequency | 15.0~1000.0Hz | ||||||
| Frequency Setting Accuracy | Accuracy: ≤0.15% Resolution: 0.1Hz | ||||||
| Voltage Distortion | ≤0.3%@50Hz/60Hz ≤1.0%@15-1kHz | ||||||
| Programmable Output Impedance Amplitude | 0Ω+200μH~1Ω+1mH | ||||||
| Harmonic Amplitudes | 2-40 times | ||||||
| Interharmonic Amplitudes | 15-2400Hz | ||||||
| AC Measurement Indicators | |||||||
| Voltage Measurement Accuracy | Accuracy: 0.2%FS+0.2% display value Resolution: 0.1V | ||||||
| Effective Value Current Measurement Accuracy | Accuracy: 0.3%FS+0.4% display value Resolution: 0.1A | ||||||
| Peak Current Measurement Accuracy | Accuracy: 0.6%FS+0.4% display value Resolution: 0.1A | ||||||
| Power Measurement Accuracy: Accuracy | 0.4%FS+0.4% display value Resolution: 0.1W | ||||||
| Harmonic Measurement Amplitudes | 2-40 times | ||||||
| DC Output Specifications: | |||||||
| Rated Power | 500W | 1kW | 2kW | 3kW | |||
| Output Voltage | Low range | 0.0~212.0V | |||||
| High range | 0.0~424.0V | ||||||
| Voltage Setting Accuracy | Accuracy: ±1V Resolution: 0.1V | ||||||
| Rated Current | Low range | 4A | 8A | 16A | 24A | ||
| High range | 2A | 4A | 8A | 12A | |||
| Remote Interface: | |||||||
| Communication Interfaces | Standard: RS232, Optional: GPIB | ||||||
| Input Parameters | |||||||
| Input Phases | Single-phase two-wire + PE | ||||||
| Input Voltage Range | 90~250V | ||||||
| Input Frequency Range | 47~63Hz | ||||||
| Input Power Factor | ≥0.97 | ||||||
| Operating Environment: | |||||||
| Operating Temperature | 0~40℃ | ||||||
| Storage Temperature | -40~85℃ | ||||||
| Operating Humidity | 30~90%RH (non-condensing) | ||||||
| Dimensions (W×H×Dmm) | 483×134×610 | 483×268×610 | 483*356*610 | ||||