Rooftop Photovoltaic Module Flammability Tester UL 790 IEC 61730-2 with 6000×2200×2000mm Dimensions and 850kg Weight
Price:
USD 10000-11000/set
MOQ:
1set
Delivery Time:
30days
Brand:
GOLD
Product Description
Product Overview
The Rooftop Photovoltaic Cell Module Flammability Tester is engineered to evaluate fire resistance performance of roofing materials and photovoltaic modules according to international safety standards. This precision testing system simulates real environmental conditions to assess flame spread characteristics and material integrity under controlled fire exposure.
Compliance Standards
- UL 1730: Smoke Detection Monitors for Individual Dwelling Units
- UL 790: Standard Methods of Fire Tests for Roof Coverings
- IEC 61730-2 Annex A: Photovoltaic Module Flame Tests
- ASTM E 108-04: Standard Methods of Fire Tests for Roof Coverings
Technical Specifications
| Parameter | Specification |
|---|---|
| Electrical Requirements | AC 380V 3-Phase, 50/60Hz, 50A |
| Dimensions | 6000mm (W) × 2200mm (D) × 2000mm (H) |
| Weight | 850 kg |
| Exhaust Capacity | Minimum 400 m³/min |
| Auxiliary Requirements | Propane gas/liquefied natural gas, Compressed air, Vacuum cleaners, Computer |
Key Features
Construction Quality
Stainless steel tooling structure providing excellent corrosion resistance and durability
Temperature Control
Automatic system temperature control with precision ranges:
- Grade A/B: 760±28°C (1400±50°F)
- Grade C: 704±28°C (1300±50°F)
- Grade A/B: 760±28°C (1400±50°F)
- Grade C: 704±28°C (1300±50°F)
Gas Flow Management
High-precision gas control valves and pressure regulation for accurate flow measurement
Automation
Electronic automatic control of deck inclination rate and automatic ignition system
Airflow Control
Guide plates and slope adjustment panels ensure consistent airflow at 19±8 km/h (5.5 m/sec)
Data Acquisition
Complete DAQ system for automatic test control and comprehensive data recording
Fire Safety Classification
| Safety Level | Flame Spread Range | Test Conditions |
|---|---|---|
| Class A | 1.82 meters | 760±28°C, 21,000-22,000 Btu/min |
| Class B | 2.4 meters | 760±28°C, 21,000-22,000 Btu/min |
| Class C | 3.9 meters | 704±28°C, 18,000-19,000 Btu/min |
Performance Evaluation Criteria
The system evaluates material performance based on flame spread characteristics and structural integrity during fire exposure. Key assessment parameters include flame particle emission, roof deck exposure, and sustained burning states to determine compliance with safety standards.
Product Documentation
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Chongqing gold mechnical and electrical equipment Co., Ltd
Location
25F, China Resources Building, Xiejiawan, Jiulongpo District,Chongqing,400050,China
Contact Person
Ivy Zhang