Product Overview
The Rooftop Photovoltaic Cell Module Flammability Tester is engineered to evaluate fire resistance performance of roofing materials and photovoltaic modules according to international safety standards. This precision testing system simulates real environmental conditions to assess flame spread characteristics and material integrity under controlled fire exposure.
Compliance Standards
  • UL 1730: Smoke Detection Monitors for Individual Dwelling Units
  • UL 790: Standard Methods of Fire Tests for Roof Coverings
  • IEC 61730-2 Annex A: Photovoltaic Module Flame Tests
  • ASTM E 108-04: Standard Methods of Fire Tests for Roof Coverings
Technical Specifications
Parameter Specification
Electrical Requirements AC 380V 3-Phase, 50/60Hz, 50A
Dimensions 6000mm (W) × 2200mm (D) × 2000mm (H)
Weight 850 kg
Exhaust Capacity Minimum 400 m³/min
Auxiliary Requirements Propane gas/liquefied natural gas, Compressed air, Vacuum cleaners, Computer
Key Features
Construction Quality
Stainless steel tooling structure providing excellent corrosion resistance and durability
Temperature Control
Automatic system temperature control with precision ranges:
- Grade A/B: 760±28°C (1400±50°F)
- Grade C: 704±28°C (1300±50°F)
Gas Flow Management
High-precision gas control valves and pressure regulation for accurate flow measurement
Automation
Electronic automatic control of deck inclination rate and automatic ignition system
Airflow Control
Guide plates and slope adjustment panels ensure consistent airflow at 19±8 km/h (5.5 m/sec)
Data Acquisition
Complete DAQ system for automatic test control and comprehensive data recording
Fire Safety Classification
Safety Level Flame Spread Range Test Conditions
Class A 1.82 meters 760±28°C, 21,000-22,000 Btu/min
Class B 2.4 meters 760±28°C, 21,000-22,000 Btu/min
Class C 3.9 meters 704±28°C, 18,000-19,000 Btu/min
Performance Evaluation Criteria
The system evaluates material performance based on flame spread characteristics and structural integrity during fire exposure. Key assessment parameters include flame particle emission, roof deck exposure, and sustained burning states to determine compliance with safety standards.
Product Documentation
Rooftop Photovoltaic Cell Module Flammability Tester equipment overview showing stainless steel construction and control panel Close-up view of burner assembly and thermocouple installation for precise temperature measurement during flammability testing

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Chongqing gold mechnical and electrical equipment Co., Ltd
Location 25F, China Resources Building, Xiejiawan, Jiulongpo District,Chongqing,400050,China
Contact Person Ivy Zhang

Request A Quote

Please check your email address.
Your message must be at least 20 characters.