IEC 60695-2-2 Needle Flame Combustion Test Chamber 1000°C Range 50kg IEC 60695-11-5
Price:
USD 2850-3260/set
MOQ:
1set
Delivery Time:
30days
Brand:
GOLD
Product Description
Professional Needle Flame Testing Equipment
The IEC 60695-2-2 Needle Flame Combustion Test Chamber is engineered for precise flammability testing of electronic components and plastic materials according to international safety standards.
Product Overview
This needle flame tester is designed in compliance with IEC 60695-2-2 and IEC 60695-11-5 standards. It is specifically developed for conducting small-flame ignition experiments on electrical and electronic equipment, components, and insulating materials.
Applications
- Lighting equipment and low-voltage electrical devices
- Household appliances and electrical machinery
- Power tools and electronic instruments
- Electrical connectors and accessories
- Insulating materials and plastic components
Compliance Standards
- IEC 60695-2-2: Fire Hazard Testing - Needle-Flame Test
- IEC 60695-11-5: Fire hazard testing - Needle-flame test method
- GB 4706.1: Household and similar electrical appliances - Safety
- GB 5169.5-2008: Fire hazard testing for electric and electronic products
Technical Specifications
| Parameter | Specification |
|---|---|
| Power Supply | 110V AC 60Hz / 230V AC 50Hz |
| Ambient Temperature | 10°C ~ 35°C |
| Relative Humidity | ≤75% |
| Combustion Gas | ≥95% natural gas, propane, or butane |
| Weight | Approximately 50 kg |
Key Technical Parameters
- Burner Material: Stainless steel construction
- Burner Angles: 90° and 45° configurations
- Temperature Range: 0°C to 1000°C
- Flame Temperature: 100°C ± 2°C to 700°C ± 3°C
- Heating Rise Time: 23.5 ± 1.0 seconds
- Flame Height: 12mm ± 1mm precision control
- Ignition Time: 0s to 999.9s adjustable (standard 30s)
- Burning Time: 0s to 999.9s with automatic recording
- Test Space: ≥0.5m³ standard, customizable to 0.75m³ or 1m³
- Temperature Sensor: K-type insulated thermocouple (Φ0.5mm)
- Dimensions: 1120mm(L) × 520mm(W) × 1250mm(H)
- Exhaust System: Φ100mm diameter with automatic ventilation
Testing Methodology
The equipment utilizes a standard size (Φ0.9mm) needle burner that applies a controlled flame at a 45° angle using specific gas (butane). This enables precise evaluation of ignition risks caused by fault conditions by measuring sample burning characteristics, duration, and propagation length.
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Chongqing gold mechnical and electrical equipment Co., Ltd
Location
25F, China Resources Building, Xiejiawan, Jiulongpo District,Chongqing,400050,China
Contact Person
Ivy Zhang