IEC 60529 IP5X IP6X Sand Dust Test Chamber 1000×1000×1000mm with PLC Control for Automotive Components
This IEC 60529 IP5X IP6X Sand and Dust Test Chamber is designed for comprehensive IP protection testing of electrical and electronic products, automotive components, and seals in controlled dusty environments.
This equipment verifies the performance of electrical products, automotive and motorcycle parts, and seals during use, storage, and transportation in dusty environments. The test simulates open, dusty air conditions caused by natural or human disturbances such as vehicle movement.
Features two conical funnels with dust collection ports at the bottom. A high-pressure turbine circulating fan intake installed at the dust extraction port conveys suction to the top of the inner chamber, where it freely disperses from top to bottom, creating a continuous cycle.
- GBT2423.37-2006, Environmental Testing for Electric and Electronic Products
- IEC60068-2-68, Environmental Testing for Electric and Electronic Products
- GB/T30038-2013, Road Vehicles, Degrees of Protection for Electrical and Electronic Equipment (IP Code)
- Meets requirements for IEC60529, GB2423, GB4706, GB4208, and DIN standards
| Parameter | Specification |
|---|---|
| Workroom Dimensions | 1000×1000×1000mm (W×D×H) |
| External Box Dimensions | 1500×1500×2100mm (W×D×H) |
| Dust Blowing Temperature Range | RT +10°C to 60°C |
| Fine Dust | <75µm |
| Coarse Dust | <150µm |
| Airflow Velocity | ≤2m/s |
| Dust Concentration | 2kg/m³ |
| Talc Dosage | 2-5kg/m³ |
| Negative Pressure Differential Range | -10 to 0kPa adjustable |
| Wire Mesh Diameter | 50µm |
| Load Capacity | 20kg |
| Power Supply | AC 380V, three-phase, five-wire, 50Hz |
| Power Consumption | 6 kW (no-load) |
- Shock Time: 1s~99h adjustable
- Test Timer: 1s~99h adjustable
- Dust Blowing Control Cycle: 1s~99h adjustable
- Vacuum Time: 1s~99h adjustable
- PLC controller + touch screen (Teelong)
- Dustproof socket AC220V 16A
- Line sequence protection
- Leakage protection
- Abnormal protection
- Alarm sound prompt
Temperature: (23 ± 5)°C; Relative humidity: 25% to 70% RH; Atmospheric pressure: 86 to 106 kPa
This equipment is prohibited from testing or storing: biological samples, highly toxic substances, radioactive substances, corrosive substances, strong electromagnetic radiation sources, flammable/explosive/volatile substances, or samples that may produce highly toxic substances during testing.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.