Steel Wire Rope Flaw Detector for Elevators - Real-Time Monitoring & Diagnosing Device

Function
- Able to inspect interior and exterior of elevator steel wire for broken wires, friction damage, corrosion, deformation, jump wires, and other deficiencies.
- Product fits the GB/T21837-2008 standard, able to detect localized damage (LF) and cross sectional metal area change (LMA), and display the results in the report.
- Uses Ethernet and RJ45 plus or Wi-Fi to engage in online analysis, contains sound and light alarms.
- The program can generate different alarms based on the severity of the results.
- The device can automatically engage in inspection online.
- Able to display single or multiple wire inspection and is able to begin multiple wire inspection; actualizing one key analysis, creating a word document report.
- The sensor’s external shell contains metal exterior, has waterproof, dustproof, vibration proof, and humidity proof features.
- High stability, reliability, interference resistance, and high accuracy.
- The software is compatible with various versions of Windows
| Sensor | Testable Wire Diameter | Real-Time Alarm | Software |
|---|---|---|---|
| NDT-D15 | (Wire Diameter Less than 14mm) | Ethernet Multifunction Real Time Alarm (Wired) Ethernet Multifunction Real Time Alarm (wireless) |
Steel Wire Online Surveillance Sstem Software |
Technical Parameters
- Wire diameter: Φ6-16mm (need to set up various versions of the device);
- Greatest speed of the steel wire for the sensor: 18.0 m/s
- Recommended speed: 0.3 ~ 3 m/s;
- Sampling Frequency: 5000Hz
- Non deficient (LF localized deficiency) inspection capability:
- Localized deficiency inspection accuracy: 98%;
- Broken wire inspection accuracy 100%;
- Broken wire quantitative inspection accuracy: ≥95%
- Non deficient (LMA cross sectional metal area loss) inspection capability:
- Metal cross sectional area loss inspection: ±0.5%;
- Metal cross sectional area loss error or margin: ±0.5%
- Axle position inspection capability: ±0.3%
- Power source: computer battery 5V, flow (AC220 ±10%);
- Work temperature: -20℃~40℃
- Humidity: ≤90%RH