Porous Ceramic Glass pH Electrode 0-14pH Range for Seawater Salt Water with 5m Cable and 0-100℃ Temperature Rating

Price Negotiable
Price: USD50-200
MOQ: 1 Unit
Delivery Time: 5-8 working days
Brand: JUGE
Product Description
Technical Specifications
Parameter Specification
pH Range 0-14pH
pH Zero Point 7.00±0.25
Temperature Range 0-100℃
Pressure Resistance 0-0.6MPa
Membrane Resistance <800MΩ
Reference System Ag/AgCl
Liquid Junction Porous Ceramic
Cable Length 5m or custom
Connection Thread PG13.5
Product Overview

This porous ceramic glass pH electrode operates on the Nernst equation principle, functioning as a galvanic cell that converts chemical reaction energy into electrical energy. The sensor features a double salt bridge system with NaNO3 electrolyte solution, specifically designed for seawater and salt water applications with enhanced corrosion resistance.

Installation Methods
Porous ceramic pH electrode installation diagram showing multiple mounting configurations
  • Sidewall Installation: Ensure interface tilt angle exceeds 15 degrees
  • Top Flange Installation: Note flange dimensions and electrode insertion depth
  • Pipe Installation: Consider pipe diameter, flow velocity, and pressure
  • Flow-Through Installation: Monitor flow velocity and pressure parameters
  • Submersion Installation: Adjust bracket length according to application requirements
Maintenance & Care Guidelines
  • Before use, unscrew protective cap and immerse electrode bulb and liquid junction in sample
  • Rinse with water if salt crystals form near electrode tip from electrolyte evaporation
  • Check for air bubbles in glass bulb by shaking electrode vertically
  • Keep glass membrane hydrated for fast response; use 3 mol/L KCl storage solution
  • Clean terminals with anhydrous alcohol if contaminated; keep connections dry
  • Avoid prolonged immersion in distilled water, protein solutions, or contact with silicone grease
  • For aged electrodes with cloudy membranes, soak in 10% HCl solution then rinse thoroughly
Performance & Lifespan

With proper maintenance, electrodes typically last over 12 months under normal operating conditions. Unused electrodes maintain a shelf life of 12-24 months when stored properly. Exposure to strong acids, bases, high temperatures, or corrosive liquids may reduce operational lifespan.

Calibration Procedure
  • Use fresh pH/ORP standard buffer solutions of appropriate concentrations
  • Remove protective cap and rinse electrode with distilled water
  • Set instrument to calibration mode according to manufacturer instructions
  • After calibration completion, proceed with actual sample measurements
  • Regular cleaning and calibration ensures measurement accuracy
Note: Electrodes are consumable components and generally not covered by warranty. Replace if calibration fails after maintenance procedures.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Nanjing Juge Environmental Technology Co., Ltd.
Location Building 17, No. 99 Guangli Road, Moling Subdistrict, Jiangning District, Nanjing, Jiangsu
Contact Person Leon Chen

Request A Quote

Please check your email address.
Your message must be at least 20 characters.