Industrial Analog pH Electrode Sensor for Lime Water Calcium Hydroxide Medium | 0-14 pH Range | 0-100℃ Temperature

Price Negotiable
Price: USD50-200
MOQ: 1 Unit
Delivery Time: 5-8 working days
Brand: JUGE
Product Description
Technical Specifications
ParameterSpecification
pH Range0-14 pH
pH Zero Point7.00±0.25
Temperature Range0-100℃
Pressure Resistance0-0.6 MPa
Membrane Resistance<800 MΩ
Housing MaterialGlass
Reference SystemAg/AgCl
Liquid JunctionDouble Porous Ceramic
Double Salt Bridge SystemYes
Connection ThreadPG13.5
Cable Length5 meters (customizable)
Cable ConnectorPin, BNC, or custom
Product Overview
This industrial analog pH electrode sensor operates on the Nernst equation principle, utilizing a galvanic cell system that converts chemical reaction energy into measurable electrical energy. Designed specifically for lime water (calcium hydroxide) medium applications, the sensor features a double porous ceramic liquid junction and double salt bridge system for enhanced measurement accuracy and stability.
Installation Methods
pH electrode sensor installation diagram showing multiple mounting configurations
  • Sidewall Installation: Ensure interface tilt angle exceeds 15 degrees
  • Top Flange Installation: Note flange dimensions and electrode insertion depth
  • Pipe Installation: Consider pipe diameter, flow velocity, and pressure requirements
  • Flow-Through Installation: Monitor flow velocity and pressure conditions
  • Submersion Installation: Adjust bracket length according to application needs
Maintenance & Care Guidelines
  • Before use, unscrew protective cap and immerse electrode bulb and liquid junction in sample
  • Rinse with water if salt crystals form near electrode tip
  • Check for air bubbles in glass bulb by shaking electrode vertically
  • Keep glass membrane hydrated for fast response time
  • Store with 3 mol/L KCl solution in protective cap after use
  • Clean aged electrodes with 10% HCl solution for cloudy membranes
  • Regular cleaning and calibration ensures optimal performance
Lifespan & Calibration
With proper maintenance, electrodes typically last over 12 months in normal conditions. Shelf life for unused electrodes is 12-24 months when stored properly. Regular calibration using fresh pH/ORP standard buffer solutions is essential for measurement accuracy.
Electrodes are consumable components and generally not covered by warranty. Exposure to strong acids, bases, high temperatures, or corrosive liquids may shorten operational lifespan.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Nanjing Juge Environmental Technology Co., Ltd.
Location Building 17, No. 99 Guangli Road, Moling Subdistrict, Jiangning District, Nanjing, Jiangsu
Contact Person Leon Chen

Request A Quote

Please check your email address.
Your message must be at least 20 characters.