Power Plant Boiler Water pH Electrode Sensor for Ultrapure Water - 2-12 pH Range, 0-80℃ Temperature, NPT 3/4" Thread

Price Negotiable
Price: USD50-200
MOQ: 1 Unit
Delivery Time: 5-8 working days
Brand: JUGE
Product Description
Technical Specifications
ParameterSpecification
pH Range2-12 pH
pH Zero Point7.00±0.25
Temperature Range0-80℃
Pressure Resistance0-0.3 MPa
Temperature SensorNTC10K / NTC2.2K / PT100 / PT1000
Housing MaterialPP (Polypropylene)
Membrane Resistance<30 MΩ
Reference SystemAg/AgCl
Connection ThreadNPT 3/4"
Cable Length5m or customizable
Cable ConnectorPin, BNC, or customizable
Product Overview
This industrial pH electrode operates on the Nernst equation principle, functioning as a galvanic cell that converts chemical reaction energy into electrical energy. The sensor measures electromotive force (EMF) through two half-cells: a measuring sensor sensitive to specific ion activity and a reference sensor connected to the measurement solution.
The electrode also measures ORP (Oxidation-Reduction Potential), providing critical water quality insights by reflecting the collective redox behavior of all substances in solution. Higher ORP values indicate stronger oxidizing capacity, while lower values suggest reducing properties.
Installation Methods
Power plant boiler water pH electrode installation diagram showing five mounting configurations
  • Sidewall Installation: Ensure interface tilt angle exceeds 15 degrees
  • Top Flange Installation: Note flange dimensions and electrode insertion depth
  • Pipe Installation: Consider pipe diameter, flow velocity, and pressure
  • Flow-Through Installation: Monitor flow velocity and pressure parameters
  • Submersion Installation: Adjust bracket length according to application requirements
Maintenance & Care Guidelines
  • Before use, unscrew protective cap and immerse electrode bulb and liquid junction in sample
  • Rinse with water if salt crystals form near electrode tip from electrolyte evaporation
  • Check for air bubbles in glass bulb by shaking electrode vertically
  • Keep glass membrane hydrated for fast response - add storage solution (3 mol/L KCl) after measurement
  • Ensure terminal connections remain dry - clean with anhydrous alcohol if contaminated
  • Avoid prolonged immersion in distilled water, protein solutions, or contact with silicone grease
  • For aged electrodes with cloudy membranes, soak in 10% HCl solution then rinse thoroughly
  • Regularly clean and calibrate electrode - replace if calibration fails after maintenance
Service Life & Calibration
With proper maintenance, electrodes typically last over 12 months under normal conditions. Unused electrodes have a shelf life of 12-24 months when stored properly. Exposure to strong acids, bases, high temperatures, or corrosive liquids may shorten lifespan.
Calibration Procedure
  • Use fresh pH/ORP standard buffer solutions of appropriate concentrations
  • Remove protective cap and rinse electrode with distilled water
  • Set instrument to calibration mode according to manufacturer instructions
  • After calibration completion, proceed with actual sample measurements

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.