Customizable Soil pH Electrode Analog Probe with Glass Housing - 0-14 pH Range, 0-80°C Temperature
Price:
USD50-200
MOQ:
1 Unit
Delivery Time:
5-8 working days
Brand:
JUGE
Product Description
Technical Specifications
| Parameter | Specification |
|---|---|
| pH Range | 0-14 pH |
| Temperature Range | 0-80°C |
| Pressure Resistance | 0-0.3 MPa |
| Membrane Resistance | <800 MΩ |
| Reference System | Ag/AgCl |
| Liquid Junction | Porous Ceramic |
| Electrolyte Solution | 3.3M KCl gel |
| Dual Salt Bridge System | Yes |
Customizable Options
- Temperature Sensor: None (standard), NTC10K, PT100, or PT1000
- Connection Thread: None or customizable PG13.5
- Cable Length: 5m standard or customizable
- Cable Connector: Pin, BNC, or customizable options
Measurement Principle
This soil pH electrode operates based on the Nernst equation using potentiometric analysis. The sensor functions as a galvanic cell that converts chemical reaction energy into electrical energy, producing an electromotive force (EMF) consisting of measuring and reference half-cells for accurate pH detection.
Maintenance & Care Guidelines
- Before use, unscrew protective cap and immerse electrode bulb and liquid junction in sample
- Rinse with water if salt crystals form near electrode tip (indicates normal dialysis function)
- Check for air bubbles in glass bulb by shaking electrode vertically
- Keep glass membrane hydrated for fast response - rinse thoroughly after measurement
- Add storage solution (3 mol/L KCl) to protective cap after use
- Ensure terminal connections remain dry - clean with anhydrous alcohol if contaminated
- Avoid prolonged immersion in distilled water, protein solutions, or contact with silicone grease
- For aged electrodes with cloudy membranes, soak in 10% HCl then rinse
- Regularly clean and calibrate electrode - replace if calibration fails after maintenance
Calibration Procedure
- Use fresh pH/ORP standard buffer solutions of appropriate concentrations
- Remove protective cap and rinse electrode with distilled water
- Set instrument to calibration mode (refer to instrument manual)
- After calibration, measure actual samples for accurate readings
Product Lifespan
Under normal conditions with proper maintenance, electrodes last over 12 months. Even unused electrodes have a shelf life of 12-24 months when stored correctly. Exposure to strong acids, bases, high temperatures, or corrosive liquids may shorten lifespan. Note: Electrodes are consumables and generally not covered by warranty.
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.