Customizable Soil pH Electrode Analog Probe with Glass Housing - 0-14 pH Range, 0-80°C Temperature

Price Negotiable
Price: USD50-200
MOQ: 1 Unit
Delivery Time: 5-8 working days
Brand: JUGE
Product Description
Technical Specifications
Parameter Specification
pH Range 0-14 pH
Temperature Range 0-80°C
Pressure Resistance 0-0.3 MPa
Membrane Resistance <800 MΩ
Reference System Ag/AgCl
Liquid Junction Porous Ceramic
Electrolyte Solution 3.3M KCl gel
Dual Salt Bridge System Yes
Customizable Options
  • Temperature Sensor: None (standard), NTC10K, PT100, or PT1000
  • Connection Thread: None or customizable PG13.5
  • Cable Length: 5m standard or customizable
  • Cable Connector: Pin, BNC, or customizable options
Measurement Principle

This soil pH electrode operates based on the Nernst equation using potentiometric analysis. The sensor functions as a galvanic cell that converts chemical reaction energy into electrical energy, producing an electromotive force (EMF) consisting of measuring and reference half-cells for accurate pH detection.

Maintenance & Care Guidelines
  • Before use, unscrew protective cap and immerse electrode bulb and liquid junction in sample
  • Rinse with water if salt crystals form near electrode tip (indicates normal dialysis function)
  • Check for air bubbles in glass bulb by shaking electrode vertically
  • Keep glass membrane hydrated for fast response - rinse thoroughly after measurement
  • Add storage solution (3 mol/L KCl) to protective cap after use
  • Ensure terminal connections remain dry - clean with anhydrous alcohol if contaminated
  • Avoid prolonged immersion in distilled water, protein solutions, or contact with silicone grease
  • For aged electrodes with cloudy membranes, soak in 10% HCl then rinse
  • Regularly clean and calibrate electrode - replace if calibration fails after maintenance
Calibration Procedure
  • Use fresh pH/ORP standard buffer solutions of appropriate concentrations
  • Remove protective cap and rinse electrode with distilled water
  • Set instrument to calibration mode (refer to instrument manual)
  • After calibration, measure actual samples for accurate readings
Product Lifespan

Under normal conditions with proper maintenance, electrodes last over 12 months. Even unused electrodes have a shelf life of 12-24 months when stored correctly. Exposure to strong acids, bases, high temperatures, or corrosive liquids may shorten lifespan. Note: Electrodes are consumables and generally not covered by warranty.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Nanjing Juge Environmental Technology Co., Ltd.
Location Building 17, No. 99 Guangli Road, Moling Subdistrict, Jiangning District, Nanjing, Jiangsu
Contact Person Leon Chen

Request A Quote

Please check your email address.
Your message must be at least 20 characters.