LONROY ISO 817 UL 9540A Cell Thermal Runaway Flammable Gas Combustion Rate Tester ANSI 34 Flammable Gas Burning Test Machine

Price Negotiable
Price: Negotiable
MOQ: 1
Delivery Time: Negotiable
Brand: LONROY
Product Description

LONROY ISO 817 UL 9540A Cell Thermal Runaway Flammable Gas Combustion Rate Tester ANSI 34 Flammable Gas Burning Test Machine

 

Application range

Suitable for testing the combustion rate of flammable gases released during battery thermal runaway, using the vertical tube method.

 

Executive standard

2.1 Complies with UL 9540A, "Standard for Safety—Test Method for Evaluating Thermal Runaway Fire Propagation in Battery Energy Storage Systems," Appendix A.2.2.1 a), measuring flame spread rate using the vertical tube method;

2.2 Complies with ISO 817:2016 "Refrigerants—Designations, symbols and safety classification," Appendix C, "Test method for measuring flammable gas flame propagation velocity."

2.3 Measured basic burning velocity by the vertical tube method in accordance with Section 6 on safety group classification of ANSI/ASHRAE Standard 34-2019, "Designation and Safety Classification of Refrigerants."

 

Main features

3.1 Automatically completes the testing process, automatically records raw data and images, and evaluates test results

3.2 Equipped with an explosion-proof solenoid shut-off valve capable of withstanding instantaneous pressure surges from 0 to 20 bar, with an explosion-proof rating of NEMA7

3.3 Employing visual image detection technology, the CCD camera records the flame condition in real time, and flame morphology is extracted through image processing algorithms to calculate the flame combustion rate.

3.4 The software features an interface for pressure sensor calibration and correction.

3.5 The test chamber is treated as a "dark room" to avoid interference from external light and ensure the accuracy of flame detection.

3.6 Supports remote ignition via remote control, ensuring the safety of test personnel

3.7 Provides professional PC operation software to reduce instrument operating difficulty

 

 

LLONROY ISO 817 UL 9540A Cell Thermal Runaway Flammable Gas Combustion Rate Tester ANSI 34 Flammable Gas Burning Test Machine

 

Technical Specification

Combustion rate measurement method

Visual image detection

Maximum sampling frequency

40 Hz

Combustion rate measurement range

(0–400) cm/s

Reactor tube dimensions

length 1200 mm, inner diameter 40 mm

Reaction tube pressure resistance

≥200 kPa

Damping hole diameter

(9~11) mm, step 1 mm, 6.4 mm

Gas distribution pressure measurement range

(0–400) kPa, accuracy ±0.1% FS

Ignition energy

15 kV, 30 mA

Electrode gap

6.4 mm

Expansion tank volume

125L

Safety valve opening pressure

200 kPa

Overall dimensions

705 x 465 mm x 1680 mm

Overall machine weight

115 kg

Power supply

AC 220V, 50Hz, 1kW

 

Similar Products

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company DONGGUAN LONROY EQUIPMENT CO LTD
Location A31, 11 Floor, No 1 Building, Minjian Jinrong Building, No 111 Guantai Road, Sanyuanli Community, Nancheng Street, Dongguan, Guangdong, China
Contact Person Kaitlyn Wang

Request A Quote

Please check your email address.
Your message must be at least 20 characters.