Industrial Rexroth Hydraulic Pump A10VSO71DRG/31R-PPA12N00 A10VSO71DRG/31R-PPA42N00
Price:
negotiation
MOQ:
negotiation
Delivery Time:
negotiation
Brand:
Rexroth
Product Description
A10VSO71DRG/31R-PPA12N00 A10VSO71DRG/31R-PPA42N00 German Rexroth mechanical hydraulic industrial hydraulic pump imported with original packaging
| Product Name | Hydraulic Piston Pump |
| Brand Name | REXROTH |
| Place of Origin | Fujian, China |
| Pump Type | Piston Pump |
| Material | Cast Iron |
| Displacement | Depend on Model |
| Dimension (L*W*H) | Depend on Model |
| Maximum Flow Rate | Depend on Model |
| Power (W) | Depend on Model |
| Pressure | Depend on Model |
| Structure | Depend on Model |
| Weight | 33 (Unit: Not Specified) |
| Warranty | 1 Year |
| Package | Wooden Box |
| Showroom Location | None |
A10VSO71DRG/31R-PPA12N00 A10VSO71DRG/31R-PPA42N00 German Rexroth mechanical hydraulic industrial hydraulic pump imported with original packaging.
Available Models
A10VSO140DR/31R-PPA12N00
A10VSO140DFR1/31R-PPA12N00
A10VSO71DRG/31R-VPA12N00
A10VSO71DRG/31R-VPA42N00
A10VSO71DFR1/31L-VPA42N00
A10VSO71DFR1/31L-VPA12N00
A10VSO100DRG/31R-PPA12N00
A10VSO100DFR1/31R-PPA12N00
A10VSO100DFLR/31R-PPA12N00
A10VSO100DRG/31R-VPA12N00
A10VSO100DRG/31L-PPA12N00
A10VSO100DRG/31L-VPA12N00
A10VSO140DRG/31R-PPA12N00
A10VSO71DFR/31R-VPA12N00
A10VSO71DG/31R-VPA12N00
A10VSO45DR/31L-PPA12N00
A10VSO45DG/31R-PPA12N00
A10VSO45DRG/31R-VPA12N00-
A10VSO45DFR1/31R-VPA12N00
A10VSO45DFLR/31R-VPA12N00
A10VSO45DR/31L-VPA12N00
A10VSO71DRG/31R-PPA12N00
A10VSO71DRG/31R-PPA42N00
A10VSO71DFR1/31R-PPA12N00
A10VSO71DR/31R-VPA12N00
A10VSO45DR/31R-PPA12N00
A10VSO45DRG/31R-PPA12N00
A10VSO45DFR/31R-PPA12N00
Frequently Asked Questions
Installation & Commissioning: What is the step-by-step commissioning process for first-time operation?
Follow this sequence to avoid damage:
① Pre-filling: Inject HLP 46 oil into the pump housing via the case drain port until oil overflows; rotate the motor manually 5-8 turns to ensure all components are lubricated;
② Air bleeding: Open the pressure port valve slightly, jog the motor (10s on, 20s off) 3 times--air is purged when continuous oil flows from the pressure port;
③ Control parameter setting: For FR control, adjust the flow control knob to set max flow (e.g., 60 L/min) and the pressure limiting knob to 300 bar (20 bar below peak pressure);
④ Run-in: Operate at 50% speed (750 rpm) and 50% load for 30 minutes, check for leaks (focus on flange and port seals) and abnormal noise (normal noise ≤75 dB);
⑤ Performance test: Gradually increase to full speed and full load, verify flow stability (fluctuation ≤5%) and pressure response time (≤0.2s).
① Pre-filling: Inject HLP 46 oil into the pump housing via the case drain port until oil overflows; rotate the motor manually 5-8 turns to ensure all components are lubricated;
② Air bleeding: Open the pressure port valve slightly, jog the motor (10s on, 20s off) 3 times--air is purged when continuous oil flows from the pressure port;
③ Control parameter setting: For FR control, adjust the flow control knob to set max flow (e.g., 60 L/min) and the pressure limiting knob to 300 bar (20 bar below peak pressure);
④ Run-in: Operate at 50% speed (750 rpm) and 50% load for 30 minutes, check for leaks (focus on flange and port seals) and abnormal noise (normal noise ≤75 dB);
⑤ Performance test: Gradually increase to full speed and full load, verify flow stability (fluctuation ≤5%) and pressure response time (≤0.2s).
Can the pump be installed vertically, and what precautions apply?
Vertical installation is allowed (motor above or below the pump), but with additional precautions:
① Motor above pump: Ensure the case drain line is installed with a siphon loop (height ≥ pump center) to prevent oil from flowing back into the motor;
② Motor below pump: Fill the pump housing with oil before startup to avoid dry friction of upper bearings;
③ Suction line: Install a check valve to prevent oil from draining back to the tank when the pump is stopped;
④ Ventilation: Ensure the pump housing has good ventilation to avoid heat accumulation (vertical installation may increase temperature by 5-8°C).
① Motor above pump: Ensure the case drain line is installed with a siphon loop (height ≥ pump center) to prevent oil from flowing back into the motor;
② Motor below pump: Fill the pump housing with oil before startup to avoid dry friction of upper bearings;
③ Suction line: Install a check valve to prevent oil from draining back to the tank when the pump is stopped;
④ Ventilation: Ensure the pump housing has good ventilation to avoid heat accumulation (vertical installation may increase temperature by 5-8°C).
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Xiamen Lang Ye Hydraulic Electromechanical Equipment Co., Ltd
Location
Xia'Men City, China
Contact Person
zixin