T2 T3 Lightning Surge Protection Device 3 Phase AC SPD 220V 20kA 40kA

Price Negotiable
Price: USD$120-USD$190
MOQ: 1 piece
Delivery Time: 7-15 days
Brand: LLH
Product Description
Product features
● Full mode protection
● No leakage current, no afterflow
● Large flow capacity and super low residual pressure
● Suitable for installation in LPZ 1-2 and subsequent lightning protection zones, suitable for fine lightning protection devices in three-phase power supply systems.

 

Product Specification


Standards IEC 61643.11
SPD type T2,T3
Models

SLV-40T

SLV-80T

Nominal operating voltage Un 220Vac(50Hz)
Maximum continuous operating voltage Uc 320Vac(50Hz)
Nominal discharge current (8/20μs) In 20kA/40kA
Maximum discharge current (8/20μs) Imax 40kA/80kA
Voltage protection level In@Up ≤1.25kV/≤1.8kV
L123-N,L123-E,N-E(3kA&6kV) Uoc ≤650V
Response time tA ≤25ns
Protection Circuit L1,L2,L3-N,L1,L2,L3-E,N-E
Counting current range 0.5kA(8/20μs)-80kA(8/20μs)
Counting digit 0-999

 

Mechanical parameters

 

Installation method 4 fixed holes, DIN Rail 35mm
Screw torque 5N*m
Strip length 12mm
Wiring cross-sectional area 2.5mm²-10mm²
Product size

SLV-40T:178mmx116mmx75mm

SLV-80T:197mmx139mmx90mm

Shell material and surface technology Cold rolled steel plate painted black
Deterioration indication LED green: OK; Off: Fail
Remote signaling contact type Normally closed and normally open switching contacts
Remote signaling contact switching ability 125 Vac / 1 A, 125 Vdc A / 0.2
Maximum connection capacity of remote signaling 2.5mm²
Installation position Indoor
Degrees of protection provided by enclosure IP20
Temperature range -40℃…+80℃
Humidity range Relative humidity ≤ 95% (max 40 ℃)

 

Notices
1.Install the SPD in LPZ 1-2 or subsequent lightning protection zones, ensuring the distance to protected equipment does not exceed 10 meters.

2.Use wiring with cross-sectional area 2.5mm²-10mm² and tighten screws to 5N·m torque for secure connections.

3.Ensure reliable grounding with a ground resistance ≤4Ω to guarantee surge current diversion efficiency.

4.Replace the SPD immediately if the LED indicator turns off (failed status) or after experiencing a severe surge impact.

5.Do not disassemble the product by yourself; improper operation may damage internal components and cause safety risks.

6.Avoid using the product in environments beyond the specified temperature (-40℃~+80℃) and humidity range

 

FAQ
Q1: What is the difference between SLV-40T and SLV-80T?

A1: The core difference is nominal discharge current (In) and maximum discharge current (Imax): SLV-40T has In=20kA/Imax=40kA, while SLV-80T has In=40kA/Imax=80kA. Other performance parameters and structural design are consistent.

 

Q2: Can this SPD be used for single-phase power systems?

A2: No, SLV-40T/SLV-80T is specifically designed for three-phase systems. For single-phase applications, choose SLV-40S/SLV-80S series products.

 

Q3: What is the function of remote signaling contacts?

A3: The normally closed and normally open switching contacts allow connection to monitoring systems, enabling remote alerts when the SPD fails.

 

Q4: Does the product require regular maintenance?

A4: Regular visual inspection is recommended (quarterly): check LED status and wiring tightness. No additional maintenance is needed under normal operating conditions.

 

Q5: Is the SPD compatible with different grounding systems?

A5: Yes, it is compatible with TN, TT, and IT grounding systems, as long as the grounding resistance meets the requirement (≤4Ω).

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Shenzhen LLH Electrical Co., Ltd.
Location Room 303, Building A, Niu Lake Intelligent Park, Niu Lake Junxin, Guanlan Street, Longhua District, Shenzhen
Contact Person Ocean

Request A Quote

Please check your email address.
Your message must be at least 20 characters.