200V 300A Charge 600A Discharge Battery Comprehensive Tester For Lithium Ion Battery Pack
200V 300A Charge 600A Discharge Battery Comprehensive Tester For Lithium Ion Battery Pack
Product Description
ACEY-BIT200-300A600A battery comprehensive tester is used for comprehensive performance testing of lithium-ion power battery packs for energy storage modules, electric vehicles, electric scooters, AGVs, and garden tools. It supports all series of batteries with CH+ / P+ / CH− / P− terminals and is suitable for testing both semi-finished and finished products in the production process. The main test items include battery open-circuit voltage, AC internal resistance, continuous charge and discharge current and voltage, charge and discharge over-current protection, short-circuit protection response time, over-current delay, and post-test voltage verification.
Test Items
- Voltage: Measures voltage twice—no-load voltage and post-test voltage (especially after short-circuit protection) to verify battery condition. Voltage range: 0–120 V.
- Internal Resistance: Measures AC internal resistance at 1000 Hz. Range: 0–4000 mΩ.
- Charge Over-current Protection Current: Verifies BMS protection against excessive charge current. If no protection is present, continuous charge current is applied. Range: 0–100 A.
- Continuous Charge Current: For batteries without charge over-current protection, the charge current is set to match the charger. Range: 0–100 A.
- Charge Voltage Monitoring: Monitors voltage limits during continuous charging to detect over-range conditions. Range: 0–120 V.
- Discharge Over-current Protection & Delay: Tests automatic protection when discharge current exceeds the set value. Range: 0–500 A, max power 60 kW. Supports step and fast test modes.
- Continuous Discharge Current: Verifies the battery’s ability to sustain normal operating discharge current. Range: 0–500 A.
- Discharge Voltage Monitoring: Monitors voltage limits during continuous discharge. Range: 0–120 V.
- Short-circuit Protection Time: Measures BMS response time during momentary short circuit. Typical requirement <1000 μs. Max short-circuit current resistance up to approx. 5000 A.
- Cell Voltage Monitoring: Dynamic monitoring of individual cell voltage during charge and discharge.
- Charge / Discharge Voltage Rise & Drop: Compares end-of-charge voltage with static voltage, and end-of-discharge voltage with initial voltage, to evaluate voltage rise and drop.
Main Technical Parameter
| Item | Range | Resolution | Accuracy / Notes |
| Voltage | 0–120 V | 1 mV | ±0.1% RD + 0.1% FS |
| Internal Resistance | 0–2000 mΩ | 0.001 mΩ | ±0.1% RD + 0.1% FS |
| Charge Current | 0–100 A | 0.001 A | ±0.1% RD + 0.1% FS |
| Discharge Current | 0–500 A | 0.001 A | ±0.1% RD + 0.1% FS (500 A continuous at max voltage; higher current customizable) |
| Over-current Delay Time | 0–30 s | 1 ms | ±0.1% RD + 0.1% FS |
| Short-circuit Time | 0–2000 μs | 1 μs | ±0.1% RD + 0.1% FS |
| NTC | 0–100 kΩ | 0.001 kΩ | — |
| R1 | 0–100 kΩ | 0.001 kΩ | — |
| Operating Voltage | AC 200–240 V | — | — |
| Max Charging Power | 12 kW | — | At maximum charge current |
| Max Discharging Power | 60 kW | — | At maximum discharge current |
| Surge Voltage | <15 V | — | — |
Product Display
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.