100V 60A Charge 60A Discharge Regenerative Lithium Battery Aging Test Equipment
Price:
USD 1980~12680/Set
MOQ:
1 Set
Delivery Time:
7~35 Days
Brand:
ACEY
Product Description
100V 60A Charge 60A Discharge Regenerative Battery Aging Test Equipment For Lithium/Lead-acid/NiMH/NiCd Battery
Product Description
ACEY-BA60100-4 battery aging test equipment is designed for aging tests of battery packs including NCM, LiFePO₄, lead-acid, NiMH, and NiCd chemistries, suitable for battery packs with a common charge and discharge port.
- Stable and adjustable output voltage from 10V to 100V, with adjustable output current from 100mA to 60A, ensuring precise charge and discharge control.
- Widely used for battery module inspection and testing in battery pack manufacturing facilities.
- Applicable to battery packs for vacuum cleaners, power tools, electric scooters, and energy storage products, supporting charge, aging, and performance verification.
Test Items
- Battery pack cycle life testing
- Battery pack capacity testing
- Battery pack charge/discharge performance testing
- Battery pack temperature characteristic testing
Software Step Settings Requirements
- Charge – Constant current charging with soft-start to prevent inrush current. In continuous mode, constant current and constant voltage (CCCV) charging is supported with hardware automatically switching between modes. The transition from constant current to constant voltage is smooth, without any current spikes.
- Discharge – Constant current discharge with soft-start, ensuring no inrush current during startup.
- Rest – Current loop is disconnected, but data acquisition continues uninterrupted.
- Cycle – Supports programmable step looping based on actual test requirements, including multi-level nested cycles.
- Stop – Channel is completely stopped, with the battery fully disconnected from the equipment.
Equipment Features
- High Accuracy and Stability – Measurement precision of ±(0.1% RD + 0.1% FS) ensures reliable and stable operation.
- Flexible Channel Configuration – Each channel can be freely grouped, with independent charge and discharge settings for each group.
- Comprehensive Protection – Includes input/output protection, software and hardware safety interlocks, reverse-polarity protection, and power-failure recovery to ensure safe operation.
- Smooth Current Control – Channels start with no inrush current, and transitions from constant current to constant voltage are seamless, eliminating any current spikes.
- Networked Centralized Management – One PC can control multiple units, with network integration and remote monitoring capability.Modular Design – Plug-in cabinet structure
- simplifies maintenance and component replacement.
- Real-Time Data Monitoring – Clear and comprehensive data acquisition, with real-time monitoring and MES system integration.
- Expandable Cabinets – Cabinets can be added to expand capacity as production needs grow.
Main Technical Parameter
| NO | Item | Function requirement | ||
| 1 | Channel | 8 | ||
| 2 | Action Mode | Completely independent | ||
| 3 | Main channel work mode | Charging: constant current and constant voltage charging CCCV.&CC | ||
| Discharge: constant current discharge CD.& CP | ||||
| Rest, Stop | ||||
| Main channel test abort condition | Time, voltage, current, capacity, etc | |||
| 4 | Voltage of main channel | Votage range of Charge&discharge | 10V-100V | |
| Accuracy | ±(0.05%RD+0.05%FS) | |||
| Resolution | 1mV | |||
| Current of main channel | Maximum output current | 60A | ||
| Minimum output current | 100mA | |||
| Accuracy | ±(0.05%RD+0.05%FS) | |||
| Resolution | 1mA | |||
| Power | Output | Single channel continuous operation maximum power 6KW | ||
| Auxiliary channel parameter cut-off function | The main channel step can be set to stop or switch when the auxiliary channel signal reaches certain conditions. | |||
| 5 | Control program | Support for power-down data protection, support for power outages, manual stopping and succession of tests from data files. | ||
| Safety protection conditions can be set, including: lower voltage limit, upper voltage limit, lower current limit, upper current limit, voltage and current trend. | ||||
| Auxiliary channel protection conditions can be set and parameters can be set including: upper voltage limit, lower voltage limit, upper temperature limit and lower temperature limit. | ||||
| Cycle times | Max 9999 | |||
| Work step time unit | h,min,s are available | |||
| Data logging | Min 5S | |||
| 6 | Data display method | Loop List | cycle number, charge/discharge capacity, charge/discharge efficiency, charge/discharge energy, charge/discharge average voltage, etc. | |
| Process List | process serial number, operation mode, process time, capacity, energy, median voltage, termination voltage, termination current, etc. | |||
| Detailed list | There are record serial number, system time, accumulated time, voltage, current, energy, power, etc. | |||
| 7 | Data export method | The data can be exported to EXCEL and chart files, which can provide a variety of data analysis curves such as charging and discharging efficiency, charging and discharging curves, voltage, capacity, current time characteristics, etc., and the curves can be imported into EXCEL. | ||
| 8 | Curve Type | X coordinate: total time, charging and discharging capacity, cycle times, etc., can be set freely. | ||
| Y coordinate: total voltage, current, capacity, single body temperature, charge/discharge capacity, single body voltage, etc., can be set freely. | ||||
| 9 | Software protection | Power-down data protection, power-off pause renewal, over-voltage and over-discharge protection, over-current and under-current protection, capacity protection, over-temperature protection, abnormal current fluctuation protection, abnormal charging voltage rise rate protection, abnormal discharge voltage fall rate protection. | ||
| Hardware protection | Battery reversal, over-current protection, over-voltage protection, short-circuit protection. | |||
| Alarm function | The hardware has functions such as emergency cut-off switch, automatic shutdown after power failure, and automatic load connection and disconnection. | |||
| 10 | Output wire | Four-wire connection mode with separate current and voltage lines. | ||
| 11 | Maintainability | Modular structure, available spare parts, spare parts for timely replacement, repair, free of charge during the warranty period. | ||
| 12 | Test channel and battery pack connection method | Alligator clamp | ||
| 13 | Equipment testing environment and technical requirements | Single cabinet requires 30KW 380V three-phase four-wire power configuration, ventilation and dry plant | ||
| Working environment: temperature -10℃~40℃ / humidity: 10%~90% | ||||
Product Display
Similar Products
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Xiamen Acey New Energy Technology Co., Ltd
Location
No. 223 Qishan North Road, Huli District, Xiamen, Fujian, China
Contact Person
Allen Tang