100V 150A Regenerative Battery Pack Charge Discharge Test Equipment
100V 150A Regenerative Battery Pack Charge Discharge Test Equipment For Lithium/Lead-acid/NiMH/NiCd Battery
Product Description
ACEY-BA100150-8 battery aging test cabinet is designed for cycle life testing, capacity testing, charge and discharge performance testing, and temperature performance evaluation of battery packs, including ternary lithium, LiFePO₄, lead-acid, NiMH, and NiCd batteries. It is widely used in battery manufacturing plants for battery module production inspection, performance verification, and quality control.
Electrical Performance
- Output voltage range: 10V–100V, continuously adjustable and stable
- Output current range: 100mA–150A, continuously adjustable and stable
Equipment Features
- High measurement accuracy of ±(0.05% RD + 0.05% FS), delivering excellent stability and highly reliable test results.
- Each cabinet is equipped with one independent channel. Channels can be freely grouped via software, with charge and discharge conditions configured independently for each group.
- Complete protection functions, including input/output protection, software and hardware protection, reverse polarity protection, and power-off resume protection, ensuring safe and stable operation.
- Soft channel start-up with no inrush current. Smooth and seamless transition from constant current (CC) to constant voltage (CV), without current spikes.
- Integrated network management system. Multiple cabinets can be centrally controlled by a single PC, with support for remote monitoring.
- Modular design with a plug-in cabinet structure, enabling quick replacement and easy maintenance.Clear and comprehensive data recording with real-time monitoring, supporting MES system data upload for traceability and production management.
- Expandable cabinet configuration, allowing flexible system scaling according to testing or production needs.
-
The discharge step start uses a soft start, eliminating current surges during startup and ensuring a smooth transition from constant current to constant voltage without spikes.
-
Soft start is supported via software barcode scanning, including both barcodes and QR codes.
-
Unified control and networked integrated management allow for remote monitoring.
Main Technical Parameter
| NO | Item | Function requirement | ||
| 1 | Channel | 8 | ||
| 2 | Action Mode | Completely independent | ||
| 3 | Main channel work mode | Charging: constant current and constant voltage charging CCCV.&CC | ||
| Discharge: constant current discharge CD.& CP | ||||
| Rest, Stop | ||||
| Main channel test abort condition | Time, voltage, current, capacity, etc | |||
| 4 | Voltage of main channel | Votage range of Charge&discharge | 10V-100V | |
| Accuracy |
±(0.05%RD+0.05%FS) |
|||
| Resolution | 1mV | |||
| Current of main channel | Maximum output current | 150A | ||
| Minimum output current | 100mA | |||
| Accuracy |
±(0.05%RD+0.05%FS) |
|||
| Resolution | 1mA | |||
| Power | Output | Single channel continuous operation maximum power 15KW | ||
| Auxiliary channel parameter cut-off function | The main channel step can be set to stop or switch when the auxiliary channel signal reaches certain conditions. | |||
| 5 | Control program | Support for power-down data protection, support for power outages, manual stopping and succession of tests from data files. | ||
| Safety protection conditions can be set, including: lower voltage limit, upper voltage limit, lower current limit, upper current limit, voltage and current trend. | ||||
| Auxiliary channel protection conditions can be set and parameters can be set including: upper voltage limit, lower voltage limit, upper temperature limit and lower temperature limit. | ||||
| Cycle times | Max 9999 | |||
| Work step time unit | h,min,s are available | |||
| Data logging | Min 5S | |||
| 6 | Data display method | Loop List | cycle number, charge/discharge capacity, charge/discharge efficiency, charge/discharge energy, charge/discharge average voltage, etc. | |
| Process List | process serial number, operation mode, process time, capacity, energy, median voltage, termination voltage, termination current, etc. | |||
| Detailed list | There are record serial number, system time, accumulated time, voltage, current, energy, power, etc. | |||
| 7 | Data export method | The data can be exported to EXCEL and chart files, which can provide a variety of data analysis curves such as charging and discharging efficiency, charging and discharging curves, voltage, capacity, current time characteristics, etc., and the curves can be imported into EXCEL. | ||
| 8 | Curve Type | X coordinate: total time, charging and discharging capacity, cycle times, etc., can be set freely. | ||
| Y coordinate: total voltage, current, capacity, single body temperature, charge/discharge capacity, single body voltage, etc., can be set freely. | ||||
| 9 | Software protection | Power-down data protection, power-off pause renewal, over-voltage and over-discharge protection, over-current and under-current protection, capacity protection, over-temperature protection, abnormal current fluctuation protection, abnormal charging voltage rise rate protection, abnormal discharge voltage fall rate protection. | ||
| Hardware protection | Battery reversal, over-current protection, over-voltage protection, short-circuit protection. | |||
| Alarm function | The hardware has functions such as emergency cut-off switch, automatic shutdown after power failure, and automatic load connection and disconnection. | |||
| 10 | Output wire | Four-wire connection mode with separate current and voltage lines. | ||
| 11 | Maintainability | Modular structure, available spare parts, spare parts for timely replacement, repair, free of charge during the warranty period. | ||
| 12 | Test channel and battery pack connection method |
OT terminal connection, OT terminal overcurrent greater than 100A, all channels connected one-to-one. |
||
| 13 | Equipment testing environment and technical requirements | Single cabinet requires 30KW 380V three-phase four-wire power configuration, ventilation and dry plant | ||
| Working environment: temperature -10℃~40℃ / humidity: 10%~90% | ||||
Product Display
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.