100V 250A Energy Feedback Battery Pack Testing System Cycle Life Testing Machine
Price:
USD 1980~26200/Set
MOQ:
1 Set
Delivery Time:
7~35 Days
Brand:
ACEY
Product Description
100V 250A Energy Feedback Battery Pack Testing System Cycle Life Testing Machine
Product Overview
100V 250A Battery Pack Cycle Life Testing Machine For Lithium/Lead-acid/NiMH/NiCd Battery
ACEY-BA100250-1 battery aging machine is designed for cycle life testing, capacity evaluation, charge and discharge performance testing, and temperature performance assessment of battery packs. It supports various battery types, including ternary lithium, LiFePO₄, lead-acid, NiMH, and NiCd batteries. This equipment is widely employed in battery manufacturing plants for production inspection, performance verification, and quality control of battery modules.
Applications
- Applicable to ternary, lithium iron phosphate, lead-acid, nickel-metal hydride, nickel-cadmium and other battery pack aging tests
- Applicable to same port battery packs and sub-port battery packs
- Equipment aging battery pack voltage range 10V ~ 100V, charging and discharging current range 100mA~250A adjustable
- Battery manufacturing enterprises battery module production testing
- EV/HEV power battery system high current charging and discharging detection
- High-current charging and discharging testing of battery modules, battery performance testing
- Daily battery module maintenance in battery factories and charging stations
Equipment Features
- Voltage and current accuracy ± (0.05%RD+0.05%FS), data recording time 5S/time, high stability
- The whole cabinet can hold 1 channel. Can be set for independent charging and discharging conditions after free grouping for each channel
- Complete input and output, software and hardware protection, reverse connection protection, power failure renewal, short circuit protection
- Channel start without inrush current, constant current to constant voltage seamlessly over, without any current surges
- Network integrated management, a computer centralized control, support remote monitoring
- Modular design of power unit, easy to produce, easy to maintain
- Clear and comprehensive data, real-time monitoring and uploading to MES system
Main Technical Parameters
| Item | Function Requirement |
|---|---|
| Channel | 1 |
| Action Mode | Completely independent |
| Main Channel Work Mode | Charging: constant current and constant voltage charging CCCV & CC Discharge: constant current discharge CD & CP Resting, stopping Main channel test abort condition: Time, voltage, current, capacity |
| Voltage of Main Channel | Voltage range of Charge & discharge: 10V-100V Accuracy: ±(0.05%RD+0.05%FS) Resolution: 1mV |
| Current of Main Channel | Maximum output current: 150A Minimum output current: 100mA Accuracy: ±(0.05%RD+0.05%FS) Resolution: 1mA |
| Power | Single channel continuous operation maximum power: 25KW |
| Control Program | Support for power-down data protection, support for power outages, manual stopping and succession of tests from data files Safety protection conditions can be set Cycle times: Max 9999 Work step time unit: H, min, s available Data logging: Min 5S |
| Data Display Method | Loop List: cycle number, charge/discharge capacity, charge/discharge efficiency, charge/discharge energy, charge/discharge average voltage Process List: process serial number, operation mode, process time, capacity, energy, median voltage, termination voltage, termination current Detailed list: record serial number, system time, accumulated time, voltage, current, energy, power |
| Data Export Method | Data can be exported to EXCEL and chart files, providing various data analysis curves |
| Software Protection | Power-down data protection, power-off pause renewal, over-voltage and over-discharge protection, over-current and under-current protection, capacity protection, over-temperature protection, abnormal current fluctuation protection, abnormal charging voltage rise rate protection, abnormal discharge voltage fall rate protection |
| Hardware Protection | Battery reversal, over-current protection, over-voltage protection, short-circuit protection |
| Output Wire | Four-wire connection mode with separate current and voltage lines |
| Test Channel Connection | OT clamp |
| Testing Environment | Single cabinet requires 30KW 380V three-phase four-wire power configuration, ventilation and dry plant Working environment: temperature -10℃~40℃ / humidity: 10%~90% |