20HP VSD Direct-driven Air Cooling Oil-free Industrial Air Compressor

Price Negotiable
Price: Negotiable
MOQ: 1 unit
Delivery Time: 5-15 days
Brand: AIRERA
Product Description
AIRERA 20HP VSD Series: The Ultimate Synergy of Efficiency and Purity

    Unleash the full potential of your production line with the AIRERA 20HP (15kW) VSD Direct-Driven Oil-Free Air Compressor. This industrial-grade solution is engineered for high-demand environments where 100% air purity is the standard. By integrating advanced Variable Speed Drive (VSD) with a Direct-Drive transmission, it achieves unrivaled energy savings by matching power output to your real-time air consumption.

   The robust Air Cooling architecture ensures consistent thermal management, eliminating the need for water cooling costs. With zero oil in the compression chamber, AIRERA delivers ISO Class 0 certified air, safeguarding your high-precision equipment and products from contamination. It is the smart, sustainable choice for modern industrial automation.

Advantages of OGFD Air Screw Compressor:

  • Constant Voltage and Power Saving
        The pressure comparison shown in the figure is in the operation of standard air compressor and the VFD air compressor. In standard air compressor, the loading and unloading is frequently changed between the sufficient pressure and pressure more than 1.5bar, which costs 10.5% of power consumption(more 7% of power is consumed when each 1bar is increased )compare with the inverter control. In addition, 45% of idle power energy is consumed in standby status of zero air supply in the unloading. Therefore, air supply inconstant pressure is not only very low power consumption, but also avoids the reduction of service life of the unit caused by the control of loading and unloading and the adverse factors of unstable pressure brought to the production of the enterprise.

  • Patented High-Efficiency Compressor Block

        The compressor block is constructed from 304L stainless steel,featuring a world-class sealing system that integrates mechanical seals,an air curtain chamber, labyrinth seals, and a bypass channel into a single unit.


  • Unloading Valve

        The independently designed unloading valve (Patent No.: ZL200520058468.2) is specifically engineered for vortex characteristics, enabling the screw compressor to achieve a fully sealed operation with 0–100% capacity, ensuring stepless air delivery.


Technical Specifications - 15KW Air Cooling Compressor
15KW Air Cooling Compressor Parameters
ITEM UNIT MODEL OWFD-15D A/B/CVP
Free air delivery m³/min 1.10-1.90|1.10-1.80
Max. working pressure MPa  0.7-1.0
Compressor type
Oil-free screw compressor
Cooling type
Air cooling
Driven type
Direct driven
Inlet status - Temperature 2-40
Inlet status - Pressure MPa Atmospheric pressure
Inlet status - Relative humidity
≤90%
Noise Level dB(A) ≤58
Drive rotor speed rpm 3000
Compressed air outlet temperature Ambient temperature+20
Cooling air flow m³/hr 5800
Control mode
Intelligent controller
Safety valve set pressure MPa 0.77 ~ 1.10
Lubricating water volume L 20
Compressed air outlet connection
G1
Dimension - L mm 1170
Dimension - W mm 900
Dimension - H mm 1100
Net Weight kg 660
Motor - Model
TYCP132S3-8
Motor - Speed rpm 3000
Motor - Rated Power KW 15
Motor - Service factor
1.2
Motor - Protection type
IP55
Motor - Efficiency
IE5
Motor - Startup mode
Frequency conversion starting
Motor - Voltage V 400(Special on request)
Motor - Frequency Hz 50-200(Special on request)
Motor - Rated current A 26.3
Motor - Weight of motor kg 70

AIRERA 15kW Screw Air Compressor: Frequently Asked Questions (FAQ)
Can the VSD compressor maintain stable pressure if my factory's air demand fluctuates?
This is the primary strength of VSD units. It responds to pressure changes in milliseconds, keeping fluctuations within ±0.01MPa. Constant pressure significantly improves the yield rate in precision manufacturing, such as food packaging and electronics assembly.
What is the maintenance frequency for this model?
Extremely low. With no lubrication system, there’s no need for oil or oil filter changes. Maintenance is limited to replacing the air intake filter every 2,000–3,000 hours and periodically cleaning the cooler. This "low-maintenance" nature significantly cuts labor costs on industrial sites.
How does the direct-drive structure help extend the machine's lifespan?

Direct-drive achieves perfect coaxial alignment between the motor and air end, eliminating radial forces on bearings caused by belt tension. This significantly reduces the load on air-end bearings, extending the machine's mechanical lifespan by over 30% compared to belt-driven models while maintaining minimal vibration.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Shanghai Bestcomp Compressor Co., Ltd
Location NO:1-2F,No.365,366,377,East Gubei Rd,baoshan Dist, Shanghai,CN
Contact Person Zhou

Request A Quote

Please check your email address.
Your message must be at least 20 characters.