SpaceLogic KNX 4 Channel Hybrid Switch Actuator Manual Control MTN6700-0104
Price:
Negotiable
MOQ:
5
Delivery Time:
7 days
Brand:
Schneide
Product Description
SpaceLogic KNX 4-Channel Hybrid Switch Actuator MTN6700-0104
Professional Schneide Electric actuator with manual control in white finish, designed for advanced building automation systems.
KNX Software Functions
| Core Functions | Live signal, enabling safety priority function, central control of switching/curtains function, sending delay after bus voltage recovery |
|---|
Actuator Functions
Switching Actuator Functions
| Basic Functions | Preset, Logic, Threshold, Safety, Forced, Locking, Central, Time function for each channel |
|---|---|
| Scene Functions | Including delay, flashing and staircase timer |
| Bus Voltage Fault Recovery | Relay state after bus voltage failure/recovery; object value of the Switch object after voltage recovery |
| Status Feedback | Status feedback/ETS download object per channel |
Heating Actuator Functions
| Control Protocol | PWM cycle time (continuous), 1 bit/1 byte control telegram |
|---|---|
| Additional Functions | Valve protection, Safety, Locking, Forced, Cyclic continuous operation, Operation as NC/NO |
| Bus Voltage Fault Recovery | Valve position after bus voltage failure or recovery |
| Status Feedback | KNX Response value when contact is opened or closed |
Power Supply & Electrical Parameters
| Power Supply | KNX Bus |
|---|---|
| Rated Current | 9 mA, maximum 20 mA/24 V |
| KNX Power Consumption | ≤ 840 mW |
| Nominal Voltage | AC 250 V; 50/60 Hz |
| Nominal Power per Contact | AC1 10 A operation (cosφ = 0.8) acc. with IEC 60947-4-1 AC3 6 A operation (cosφ = 0.45) acc. with IEC 60947-4-1 |
| Relay Parameters | Switching frequency at rated load: Maximum 60 operation/min Mechanical service life: ≥ 1×10⁹ Inrush current: 320 A/2 ms |
Load Compatibility
| Load Type | Maximum Load Power |
|---|---|
| Incandescent lamp | 2500 W |
| Fluorescent lamp | 250 W |
| Electronic transformer for extra low voltage lamps (e.g., halogen lamps) | 1100 W |
| Iron core transformer for extra low voltage lamps (e.g., halogen lamps) | 900 W |
| LED lamp | 300 W (cosφ ≥ 0.6); 150 W (0.5 ≤ cosφ < 0.6) |
| Capacitive loads | 100 µF, 10 A, 140 µF |
| Motors | 1500 VA (cosφ = 0.6) |
Physical & Environmental Parameters
| Protection Class | IP20 |
|---|---|
| Insulation Category | Overvoltage category III, pollution degree 2 |
| Operating Temperature | -5...+45℃ |
| Storage Temperature | -25...+55℃ |
| Transport Temperature | -25...+70℃ |
| Maximum Humidity | 93%, no condensation |
| Installation Height | As high as 2000 m above sea level |
| Dimensions (W×H×D) | 72×90×64 mm |
Connection & Contents
| KNX Bus Connection | Bus connection terminal |
|---|---|
| Mains Connection Port | Screw terminal blocks, 2×6-gang |
| Contents | With bus connecting terminal and cable cover |
Application Scenarios
- Smart Buildings: Connects mechanical wall switches to control lighting, blinds, or HVAC (e.g., a light switch triggering KNX switch actuators).
- Access Control & Security: Links door contacts, emergency buttons, or motion sensors to trigger alarms or lighting (e.g., fire alarm contacts activating emergency lighting).
- Industrial Automation: Integrates with equipment limit switches or sensors to monitor machine status (e.g., elevator position signals linking to lobby lighting).
- Hotel & Office Buildings: Connects occupancy sensors or card readers to automate energy-saving modes (e.g., guest card removal cutting off room power).
Similar Products
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Maituo Intelligent Technology Co.,Ltd
Location
1st Floor, Building 4, Xindao Street, Yazhou District, Sanya City, Hainan Province, China
Contact Person
Nora