Maituo Intelligent Technology Co.,Ltd
                                                                                                           
Verified Supplier
7 Years
Since 2019
Menu

CP-LI-PR-TR-1600 Schneider CP Wet Media Pressure Transmitter 0-1600 kPa Water System Analog Output

Price Negotiable
Price: Negotiable
MOQ: 5
Delivery Time: 7 Days
Brand: Schneider
Product Description
CP-LI-PR-TR-1600 Schneider CP Wet Media Pressure Transmitter 0-1600 kPa Water System Analog Output
The CP-LI-PR-TR-1600 is a wet media pressure transmitter from the Schneider Electric CP series, designed for permanent connection to liquid circuits. With a measuring range of 0-1600 kPa and maximum non-destructive pressure of 3200 kPa, this hydronic instrument features a diaphragm-separated pressure sensing element with wetted parts specifically chosen for water compatibility.
Product Overview
This transmitter is engineered for chilled water and condenser water pipework applications where readings feed plant control, pump staging, or monitoring systems. It provides a standard analog signal readable by DDC controllers on universal inputs, with an accuracy of ±0.5% of full scale suitable for system pressure monitoring.
Specifications
Product Type Wet media pressure transmitter for hydronic systems
Order Number CP-LI-PR-TR-1600
Series CP series pressure transmitters
Media Wet media, liquid service (chilled and condenser water)
Measuring Range 0 to 1600 kPa
Maximum Pressure 3200 kPa (non-destructive)
Accuracy ±0.5% of full scale
Output Signal Analog output selectable between 0-10 V DC and 4-20 mA
Output Load ≥10 kOhm for voltage output, low impedance for current output
Supply DC supply for both output types, AC supply for voltage output
Process Connection Threaded connection to pipework
Mounting Pipe or manifold installation at measurement point
Compliance CE marking; RoHS and REACH declarations
System Integration
Proper installation requires careful consideration of tapping point hydraulics. Avoid placements on pipe bends, at high points where air collects, or downstream of throttled valves. Ensure proper venting and correct orientation to prevent air entrapment at the diaphragm, which can cause temperature-dependent drift.
Important: Match output type to controller input and verify scaling corresponds to the device's actual range. Installation of isolation valves enables transmitter removal without circuit drainage.
Applications
  • Chilled water and condenser water distribution systems
  • Differential pressure monitoring across pumps and terminal branches
  • Pump staging sequences for mechanical fault detection
  • District cooling substations and central plant rooms
  • Building management system dashboards and energy reporting
  • Water treatment and filtration system maintenance monitoring

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Maituo Intelligent Technology Co.,Ltd
Location 1st Floor, Building 4, Xindao Street, Yazhou District, Sanya City, Hainan Province, China
Contact Person Nora

Request A Quote

Please check your email address.
Your message must be at least 20 characters.