| Construction Materials | - Ceramic Substrate: Aluminum Oxide (Al2O3)
- Bottom Electrode: Silver (Ag)
- Top Electrode: Silver Palladium (Ag, Pd)
- Resistor Layer: Silver (Ag), Palladium (Pd), Ruthenium Dioxide (RuO2), Glass (Glass)
- Primary Overcoat: Glass (Glass)
- Secondary Overcoat: Epoxy Resin (Epoxy)
- Edge Electrode: Nickel-Chromium Alloy (NiCr)
- Barrier Electrode: Nickel Layer (Ni)
- External Electrode: Tin Layer (Sn)
- Marking: Epoxy Resin (Epoxy)
|
| Dimensions (mm) | | Type | L | W | t | a | b | | HP02 | 1.000.10 | 0.500.10 | 0.300.10 | 0.200.10 | 0.250.10 | | HP03 | 1.600.15 | 0.800.15 | 0.400.10 | 0.300.20 | 0.300.20 | | HP05 | 2.000.20 | 1.250.15 | 0.500.10 | 0.300.20 | 0.400.20 | | HP06 | 3.200.20 | 1.600.15 | 0.550.10 | 0.500.20 | 0.500.20 | | HP07 | 3.200.20 | 2.600.15 | 0.550.10 | 0.500.20 | 0.500.20 | | HP10 | 5.000.20 | 2.500.15 | 0.550.10 | 0.600.20 | 0.500.20 | | HP11 | 4.500.20 | 3.200.20 | 0.550.10 | 0.600.20 | 0.600.20 | | HP12 | 6.400.20 | 3.200.15 | 0.550.10 | 0.600.20 | 0.500.20 | |
| Derating Curve Operating Temperature Range | - Curve applies to CLHP02, CLHP03, CLHP05, CLHP06, CLHP07, CLHP10, CLHP11, CLHP12.
- Operating Temperature Range: -55~125, -55~155.
- Rated load (rated power) shall be derated in accordance with the derating curve for ambient temperatures over 70.
|
| Ratings | | Type | Rated Power | Resistance Range | Max. Working Voltage | Max. Overload Voltage | | HP02 | 1/10W | 1~10M | 50V | 100V | | HP03 | 1/8W | 75V | 150V | | HP05 | 1/4W | 150V | 300V | | HP06 | 1/2W | 200V | 400V | | HP07 | 3/4W | 200V | 400V | | HP10 | 1W | 200V | 400V | | HP11 | 1W | 200V | 400V | | HP12 | 2W | 200V | 400V | Note: Maximum working voltage is calculated by E=(PR). If calculated voltage is less than the table value, use the calculated voltage. If greater, use the table value. |
| TCR Values (ppm/) | | Type | Resistance Range | Resistance Tolerance | | | 0.1% | 0.25% | 0.5% | 1% | 5% | 10% | | HP02 | 1~10M | / | / | / | 300 | / | / | | HP03 | 250 | / | / | | HP05 | 100 | / | / | | HP06 | 100 | / | / | | HP07 | 100 | / | / | | HP11 | 100 | / | / | | HP10 | 100 | / | / | | HP12 | 100 | / | / | |
| Reliability Test Methods (IEC 60115-1) | | Item | Specifications | Test Methods | | Solderability | 95% Cover Min | 2355, 3s0.5s | | Resistance To Soldering Heat | No mechanical damage, R(1.0%R+0.05 ) | 2705, 10s1s | | Substrate Bending Test | No mechanical damage, R(1.0%R+0.05 ) | Bending distance varies by size (e.g., 0402:5mm), Duration: 60s5s | | T.C.R | Within specified T.C.R | +25/-55/+25/+125/+25 | | Short Time Overload | R(1.0%R+0.05 ) for 0.1% to 1%; R(2.0%R+0.05 ) for 5%, 10% | 2.5 times rated voltage or max. overload voltage (whichever is lower) for 5s | | Leaching | 95% Coverage | 260C5C for 30 seconds | | Thermal Shock | R(0.5%R+0.05 ) for 0.1% to 1%; R(1.0%R+0.05 ) for 5%, 10% | -55(30min)--normal temp(5min)--155(30min), 300 cycles | | Component Solvent Resistance | No mechanical damage, R(1.0%R+0.05 ) | Iso-propyl alcohol (IPA), 235, 10h | | Damp Heat, Steady State | R(1.0%R+0.05 ) for 0.1% to 1%; R(2.0%R+0.05 ) for 5%, 10% | 402, 93%3%RH, 1000h, rated voltage or limiting element voltage (whichever is lower) for 1.5h ON/0.5h OFF | | Endurance at 70 | R(1.0%R+0.05 ) for 0.1% to 1%; R(2.0%R+0.05 ) for 5%, 10% | 702, 1000h, rated voltage or limiting element voltage (whichever is lower) for 1.5h ON/0.5h OFF | | Voltage Proof | No breakdown or flashover | AC 100V between substrate and terminations for 1min | | Insulation Resistance | 1000M Min | DC 100V15V between substrate and terminations for 1min | | Intermittent Overload | No mechanical damage, R(5.0%R+0.05 ) | 2.5 times rated voltage or max. overload voltage (whichever is lower) for 1s ON/25s OFF, 10000 cycles | | Shear Test | No mechanical damage | Applying force varies by size (e.g., 0402:5N), Duration: 10s1s | |
| Recommended Solder Pad Size (mm) | | Type | A | B | C | | CLHP02 | 0.41 | 1.43 | 0.64 | | CLHP03 | 0.82 | 2.86 | 1.19 | | CLHP05 | 0.97 | 3.51 | 1.40 | | CLHP06 | 1.90 | 4.50 | 1.75 | | CLHP07 | 1.90 | 4.50 | 3.00 | | CLHP10 | 2.65 | 7.75 | 3.00 | | CLHP11 | 2.50 | 7.50 | 3.70 | | CLHP12 | 3.40 | 10.00 | 3.70 | |
| Soldering Condition | | Method | Preheat Zone | Peak Temperature | Duration at Peak | | Reflow Soldering | 150~180, 9030s | +2505 | 5s | | Wave Soldering | 25~100, 505s | +235 or higher | 10s10s | Note: Peak temperature for reflow is +235~260, max 10s. For soldering iron: 350, max 3s. |
| Packaging - Tape Specification (mm) | | Type | A | B | W | F | T1 | T2 | P | | CLHP02 | 0.650.05 | 1.200.1 | 8.00.2 | 3.50.05 | / | 0.450.1 | 2.00.1 | | CLHP03 | 1.100.1 | 1.900.1 | 8.00.2 | 3.50.05 | / | 0.600.1 | 4.00.1 | | CLHP05 | 1.650.2 | 2.400.2 | 8.00.2 | 3.50.05 | / | 0.750.1 | 4.00.1 | | CLHP06 | 2.000.2 | 3.600.2 | 8.00.2 | 3.50.05 | / | 0.750.1 | 4.00.1 | | CLHP07 | 2.800.2 | 3.500.2 | 8.00.2 | 3.50.05 | / | 0.750.1 | 4.00.1 | | CLHP10 | 2.900.2 | 5.500.2 | 12.00.2 | 5.50.05 | 0.20.05 | 1.00.1 | 4.00.1 | | CLHP11 | 3.600.2 | 5.000.2 | 12.00.2 | 5.50.05 | 0.20.05 | 1.00.1 | 4.00.1 | | CLHP12 | 3.600.2 | 6.900.2 | 12.00.2 | 5.50.05 | 0.20.05 | 1.00.1 | 4.00.1 | |
| Packaging - Reel Specification (mm) | | Type | M | W | T | A | B | C | D | | CLHP02, CLHP03 | 1782.0 | 9.51.0 | 12.51.5 | 2.00.5 | 13.00.5 | 21.00.5 | 58.02.0 | | CLHP05, CLHP06, CLHP07 | 1782.0 | 12.51.0 | 15.01.5 | 3.00.5 | 13.00.5 | 21.00.5 | 58.02.0 | | CLHP10, CLHP11, CLHP12 | 1782.0 | 12.51.0 | 15.01.5 | 3.00.5 | 13.00.5 | 21.00.5 | 58.02.0 | |
| Packaging Quantity | | Packaging Style | CLHP02 | CLHP03 | CLHP05 | CLHP06 | CLHP07 | CLHP10 | CLHP11 | CLHP12 | | Tape & Reel | 10000 | 5000 | 4000 | 50000 | 10000 | 4000 | | | | Case Bulk | | | | | | | | | |
| Operation and Storage Temperature | - Operate Temperature: MIN -55C, MAX 125C /155C
- Storage Temperature: 5C to 30C
- Storage Humidity: 40% to 80%
- Shelf Life: 2 Years
|
| Resistance Value Code and Marking | Resistance Value Code: All thick film chip resistor codes correspond to their markings. Marking Rules: - E-24 Series (0603, 5%): Three digits; first two are significant figures, third is the power of 10.
- E-24 Series (0603, 1% & 0.5%): Three digits with an underline below the marking.
- E-96 Series & E-24 Series (1% & 0.5%) for 0805, 1206, 1210, 2010, 2512, 4R02, 4R03: Four digits; first three are significant figures, fourth is the power of 10.
- E-96 Series (0603): Three codes; first two for E-96 resistance value, third is a multiplier code.
- Decimal point indicated by "R".
- Jumper indicated by "0".
- 0201, 0402: No marking on the glass side.
- For non-IEC standard series, marking uses the closest IEC E24 series nominal resistance.
- Special marking requirements are printed as per agreement.
|
| Instructions for Use | Environmental Considerations: Performance may be affected by: - Use in liquids (water, oils, chemicals, solvents).
- Outdoor exposure to direct sunlight or dust.
- Exposure to sea winds or corrosive gases (Cl2, H2S, NH3, SO2, NO2).
- Exposure to static electricity or electromagnetic waves.
- Proximity to heat-producing components, plastic cords, or flammable items.
- Sealing or coating with resin or other materials.
- Use of unclean solder or water-based cleaning agents after soldering.
Precautions: - Avoid exceeding normal rated power, as it may negatively affect performance and reliability.
- Handle with care using tweezers to avoid chipping the overcoat or body.
- Ensure the soldering tip does not touch the product during manual installation.
|