Aluminum Electrolytic Capacitors - GR Series

The GR Series Aluminum Electrolytic Capacitors are designed for high ripple current and low impedance applications, operating at temperatures up to 105 with a lifespan of 2000-4000 hours. They are suitable for various electronic products requiring reliable performance.

Product Attributes

  • Brand: ChengXing ()
  • Origin: Dongguan, Guangdong, China
  • Product Type: Aluminum Electrolytic Capacitor
  • Series: GR Series
  • Certifications/Standards: JIS- C-5101-4 (IEC 60384)

Technical Specifications

Item Performance Characteristics Value
Operating Temperature Range -40 ~ +105
Rated Working Voltage Range 6.3 ~ 100V
Nominal Capacitance Range 2.2 ~ 4700F
Capacitance Tolerance (120Hz, +20) 20%
Leakage Current (after 2 min @ rated voltage, +20) L0.01CV or 3(A) (whichever is greater)
Dissipation Factor (tan ) (120Hz, +20) See table below
Low Temperature Characteristics (120Hz) Z-25/Z+20 4 (for 6.3V), 3 (for 10V), 2 (for 16V)
Low Temperature Characteristics (120Hz) Z-40/Z+20 8 (for 6.3V), 6 (for 10V), 4 (for 16V), 3 (for 25V)
Load Life (105) 2000Hrs (D:5~6.3), 3000Hrs (D:8~10), 4000Hrs (D12.5)
Shelf Life (105, no load) 1000 Hrs

Dissipation Factor (tan ) at 120Hz, +20:

Voltage (V) 6.3 10 16 25 35 50 63 100
tan (max) 0.22 0.19 0.16 0.14 0.12 0.10 0.09 0.08

For capacitance >1000F, add 0.02 for every additional 1000F.

Ripple Current & Frequency Multipliers (at 105):

Freq. (Hz) Cap. (F) 50(60) 120 1k 10k 100k
~33 0.40 0.55 0.80 0.90 1.00
39~330 0.60 0.70 0.90 0.95 1.00
390~1000 0.65 0.80 0.98 1.00 1.00
1200~ 0.80 0.90 0.98 1.00 1.00

Standard Ratings (DxL mm; Ripple Current mA/rms at 100kHz, 105):

Voltage (Code) Cap. (F) DxL IMP R.C DxL IMP R.C DxL IMP R.C DxL IMP R.C DxL IMP R.C DxL IMP R.C
6.3V 100 5*11 0.580 140 5*11 0.580 140 6.3*12 0.250 300
120 5*11 0.530 165 5*11 0.530 140 6.3*12 0.250 320
150 6.3*12 0.250 185 6.3*12 0.250 340 6.3*12 0.220 340 8*12 0.150 500
180 6.3*12 0.250 255 6.3*12 0.250 340 6.3*12 0.220 340 8*12 0.150 580
220 6.3*12 0.250 275 6.3*12 0.220 340 6.3*12 0.220 340 8*12 0.150 600
270 6.3*12 0.220 280 6.3*12 0.220 340 8*12 0.150 640
330 6.3*12 0.220 340 6.3*12 0.220 340 8*12 0.130 640 8*12 0.130 580
390 8*12 0.130 600 8*12 0.130 640 8*12 0.130 640
470 8*12 0.130 640 8*12 0.130 640 8*12 0.130 640 10*13 0.100 865
560 8*12 0.130 640 8*12 0.130 640 10*13 0.100 880
10V 100 5*11 0.580 140 5*11 0.580 140 6.3*12 0.250 300
120 5*11 0.530 165 5*11 0.530 140 6.3*12 0.250 320
150 6.3*12 0.250 185 6.3*12 0.250 340 6.3*12 0.220 340 8*12 0.150 500
180 6.3*12 0.250 255 6.3*12 0.250 340 6.3*12 0.220 340 8*12 0.150 580
220 6.3*12 0.250 275 6.3*12 0.220 340 6.3*12 0.220 340 8*12 0.150 600
270 6.3*12 0.220 280 6.3*12 0.220 340 8*12 0.150 640
330 6.3*12 0.220 340 6.3*12 0.220 340 8*12 0.130 640 8*12 0.130 580
16V 100 5*11 0.580 140 5*11 0.580 140 6.3*12 0.250 300
120 5*11 0.530 165 5*11 0.530 140 6.3*12 0.250 320
150 6.3*12 0.250 185 6.3*12 0.250 340 6.3*12 0.220 340 8*12 0.150 500
180 6.3*12 0.250 255 6.3*12 0.250 340 6.3*12 0.220 340 8*12 0.150 580
220 6.3*12 0.250 275 6.3*12 0.220 340 6.3*12 0.220 340 8*12 0.150 600
270 6.3*12 0.220 280 6.3*12 0.220 340 8*12 0.150 640
330 6.3*12 0.220 340 6.3*12 0.220 340 8*12 0.130 640 8*12 0.130 580
390 8*12 0.130 600 8*12 0.130 640 8*12 0.130 640
470 8*12 0.130 640 8*12 0.130 640 8*12 0.130 640 10*13 0.100 865
560 8*12 0.130 640 8*12 0.130 640 10*13 0.100 880
25V 33 6.3*12 0.500 230 39 6.3*12 0.500 265 47 6.3*12 0.250 300
39 6.3*12 0.500 295 47 6.3*12 0.250 315 8*12 0.420 515
47 6.3*12 0.250 300 56 6.3*12 0.250 315 8*12 0.420 535
56 6.3*12 0.240 340 68 6.3*12 0.240 340 8*12 0.420 555 10*13 0.200 760
68 6.3*12 0.230 625 82 6.3*12 0.230 625 8*12 0.420 555 10*13 0.200 760
82 6.3*12 0.220 320 100 6.3*12 0.220 340 8*12 0.220 640 10*13 0.200 780
100 6.3*12 0.220 340 120 8*12 0.200 565 8*12 0.200 655 10*13 0.200 780 8*16 0.200 730
120 8*12 0.200 565 150 8*12 0.180 580 8*12 0.180 670 10*17 0.130 825 8*20 0.130 825
150 8*12 0.180 580 180 8*12 0.150 600 10*13 0.130 760 10*17 0.130 855 10*17 0.130 875
180 8*12 0.150 600 220 8*12 0.130 620 8*12 0.130 640 10*17 0.130 875 10*25 0.093 1025
35V 33 6.3*12 0.500 230 39 6.3*12 0.500 265 47 6.3*12 0.250 300
39 6.3*12 0.500 295 47 6.3*12 0.250 315 8*12 0.420 515
47 6.3*12 0.250 300 56 6.3*12 0.250 315 8*12 0.420 535
56 6.3*12 0.240 340 68 6.3*12 0.240 340 8*12 0.420 555 10*13 0.200 760
68 6.3*12 0.230 625 82 6.3*12 0.230 625 8*12 0.420 555 10*13 0.200 760
50V 33 6.3*12 0.500 230 39 6.3*12 0.500 265 47 6.3*12 0.250 300
39 6.3*12 0.500 295 47 6.3*12 0.250 315 8*12 0.420 515
47 6.3*12 0.250 300 56 6.3*12 0.250 315 8*12 0.420 535
56 6.3*12 0.240 340 68 6.3*12 0.240 340 8*12 0.420 555 10*13 0.200 760
68 6.3*12 0.230 625 82 6.3*12 0.230 625 8*12 0.420 555 10*13 0.200 760
63V 15 6.3*12 1.880 115
22 6.3*12 1.050 115
27 6.3*12 1.050 120
33 6.3*12 1.050 125
100V 15 6.3*12 1.880 115
22 6.3*12 1.050 115
27 6.3*12 1.050 120

Usage Precautions

Circuit Design:

  • Use within rated performance limits, avoid high temperatures, overcurrent, overvoltage, reverse voltage, AC voltage, and rapid charge/discharge cycles.
  • Select capacitors with a lifespan comparable to the machine's.
  • Ensure complete isolation between capacitor terminals, casing, and circuit.
  • Avoid using if casing insulation is insufficient.
  • Do not use in environments with direct contact with water, saltwater, oil, condensation, harmful gases, sunlight, ozone, UV radiation, radioactive substances, or excessive vibration/shock.

Installation:

  • Ensure correct polarity and matching hole spacing.
  • Leave space above the safety vent.
  • Avoid placing other components or wiring above the vent.
  • Avoid placing other wiring near the capacitor on the PCB.
  • Minimize heat-generating components around the capacitor.
  • On double-sided PCBs, avoid unnecessary substrate holes and via holes near the capacitor.
  • Ensure current equalization for parallel connections and voltage equalization for series connections.

Assembly & Soldering:

  • Prevent direct contact between terminals and short circuits.
  • Avoid exposure to water, oil, condensation, sunlight, ozone, UV, radiation, or harmful gases.
  • Do not exceed specified vibration and shock limits.
  • Do not use dropped capacitors.
  • Do not install deformed capacitors.
  • Ensure proper soldering temperature, time, and number of times as per specifications.
  • Avoid solder adhering to areas other than terminals.
  • Do not immerse the capacitor body in solder solution.
  • Prevent other products from falling and hitting the capacitor during soldering.
  • Do not use capacitors that have been removed from the machine for inspection or testing.
  • Discharge capacitors with regenerative voltage using a ~1K resistor.
  • Discharge long-term stored capacitors using a ~1K resistor.

Cleaning:

  • Avoid using cleaning agents. If necessary, clean within product specification limits.
  • Ensure proper cleaning agent management (conductivity, pH, specific gravity, moisture).
  • After cleaning, do not store in cleaning liquid or sealed containers. Dry with hot air below the maximum operating temperature.

Fixing Agents & Coatings:

  • Do not use halogen-containing fixing agents or resin coatings.
  • Ensure no solder residue or dirt remains between the PCB and capacitor.
  • Dry thoroughly before applying fixing agents/coatings to prevent clogging.

Bolt Type Installation:

  • For vertical installation, pressure valve must face upwards.
  • For horizontal installation, ensure the pressure valve or positive terminal faces upwards.

Maintenance & Disposal:

  • Regular inspections (visual and performance testing) are required for industrial capacitors.
  • In case of vent opening, cut off main power.
  • Keep face away from vent during operation; flush eyes with water if exposed to ejected gas. Wash skin with soap if electrolyte spills.
  • For overseas export, be cautious with fumigation (e.g., potassium bromide) due to potential corrosion. Ensure fumigant does not directly contact products and allow for thorough drying.
  • Store in a cool, dry indoor environment (5-30,
  • Do not store in prohibited environments.
  • Dispose of waste capacitors by puncturing/crushing and incineration, or by handing over to professional recyclers.

Part Number System: The system encodes capacitance, tolerance, voltage, sleeve material, shape, color, series, and other features. (Detailed breakdown not fully available in source text for all fields).


Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Beijing Silk Road Enterprise Management Services Co., Ltd.
Location 16 Floor, Unit B, Jiatai International Mansion, No 41, Dongsihuan Zhong Road, Chaoyang District, Beijing
Contact Person Sellina

Request A Quote

Please check your email address.
Your message must be at least 20 characters.