Electronic component GLE GCRH127M-101MC with Mn-Zn magnetic powder and phenolic epoxy resin adhesive
Price:
Negotiable
MOQ:
Negotiable
Delivery Time:
Negotiable
Product Description
Product Overview
The GCRH127M series is a type of electronic component manufactured by Shenzhen Glorious Electronic Co., Ltd. (GLE). It is designed for various applications requiring specific electrical properties, as detailed in the provided specifications.
Product Attributes
- Brand: GLE
- Origin: China (for Magnetic powder, Glue, Electrode), Germany (for Wire)
- Materials: Magnetic powder (Mn-Zn), Wire (Polyurethane-system coated copper wire), Glue (Phenolic epoxy resin), Electrode (Tinned copper)
- Color: White printing
- Certifications: RoHS Comp.
Technical Specifications
| Type | Part NO. | Inductance Lo (uH) | Test Frequency (Hz/v) | DC Resistance (m) max. | Saturation Current Isat (A) Max. L/L-35% | Bending Test | Adhesion Strength | Vibration | Mechanical Shock | Free Fall Test | Solder Ability | Resistance to Soldering Heat | Dielectric Strength | Insulation Resistance | Low Temperature | Dry Heat | Damp Heat | Temperature Cycle | Temperature Drift | Operating Temperature Range | Storage Temperature Range |
| GCRH127M | GCRH127M-2R2MC | 2.2 | 100KHz/0.25V | 7 | 25.5 | L: within10% | L: within10% | L: within10% | Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes. | The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes. | 90% minimum of the surface immersed. | L: within10% | Without damage. 100V DC shall be applied for 60s between the terminal and the core. | 100Mor more. 100V DC shall be applied between the terminal and the core. | L: within10% | L: within10% | L: within10% | L: within10% | 2000 ppm/or less | -40 ~ + 125 | -40 ~ + 85 |
| GCRH127M | GCRH127M-4R7MC | 4.7 | 100KHz/0.25V | 16 | 15.9 | L: within10% | L: within10% | L: within10% | Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes. | The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes. | 90% minimum of the surface immersed. | L: within10% | Without damage. 100V DC shall be applied for 60s between the terminal and the core. | 100Mor more. 100V DC shall be applied between the terminal and the core. | L: within10% | L: within10% | L: within10% | L: within10% | 2000 ppm/or less | -40 ~ + 125 | -40 ~ + 85 |
| GCRH127M | GCRH127M-5R6MC | 5.6 | 100KHz/0.25V | 20 | 14.0 | L: within10% | L: within10% | L: within10% | Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes. | The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes. | 90% minimum of the surface immersed. | L: within10% | Without damage. 100V DC shall be applied for 60s between the terminal and the core. | 100Mor more. 100V DC shall be applied between the terminal and the core. | L: within10% | L: within10% | L: within10% | L: within10% | 2000 ppm/or less | -40 ~ + 125 | -40 ~ + 85 |
| GCRH127M | GCRH127M-6R8MC | 6.8 | 100KHz/0.25V | 21 | 13.3 | L: within10% | L: within10% | L: within10% | Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes. | The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes. | 90% minimum of the surface immersed. | L: within10% | Without damage. 100V DC shall be applied for 60s between the terminal and the core. | 100Mor more. 100V DC shall be applied between the terminal and the core. | L: within10% | L: within10% | L: within10% | L: within10% | 2000 ppm/or less | -40 ~ + 125 | -40 ~ + 85 |
| GCRH127M | GCRH127M-8R2MC | 8.2 | 100KHz/0.25V | 23 | 12.2 | L: within10% | L: within10% | L: within10% | Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes. | The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes. | 90% minimum of the surface immersed. | L: within10% | Without damage. 100V DC shall be applied for 60s between the terminal and the core. | 100Mor more. 100V DC shall be applied between the terminal and the core. | L: within10% | L: within10% | L: within10% | L: within10% | 2000 ppm/or less | -40 ~ + 125 | -40 ~ + 85 |
| GCRH127M | GCRH127M-100MC | 10 | 100KHz/0.25V | 24 | 11.2 | L: within10% | L: within10% | L: within10% | Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes. | The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes. | 90% minimum of the surface immersed. | L: within10% | Without damage. 100V DC shall be applied for 60s between the terminal and the core. | 100Mor more. 100V DC shall be applied between the terminal and the core. | L: within10% | L: within10% | L: within10% | L: within10% | 2000 ppm/or less | -40 ~ + 125 | -40 ~ + 85 |
| GCRH127M | GCRH127M-150MC | 15 | 100KHz/0.25V | 31 | 9.00 | L: within10% | L: within10% | L: within10% | Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes. | The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes. | 90% minimum of the surface immersed. | L: within10% | Without damage. 100V DC shall be applied for 60s between the terminal and the core. | 100Mor more. 100V DC shall be applied between the terminal and the core. | L: within10% | L: within10% | L: within10% | L: within10% | 2000 ppm/or less | -40 ~ + 125 | -40 ~ + 85 |
| GCRH127M | GCRH127M-180MC | 18 | 100KHz/0.25V | 35 | 5.10 | L: within10% | L: within10% | L: within10% | Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes. | The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes. | 90% minimum of the surface immersed. | L: within10% | Without damage. 100V DC shall be applied for 60s between the terminal and the core. | 100Mor more. 100V DC shall be applied between the terminal and the core. | L: within10% | L: within10% | L: within10% | L: within10% | 2000 ppm/or less | -40 ~ + 125 | -40 ~ + 85 |
| GCRH127M | GCRH127M-220MC | 22 | 100KHz/0.25V | 40 | 7.57 | L: within10% | L: within10% | L: within10% | Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes. | The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes. | 90% minimum of the surface immersed. | L: within10% | Without damage. 100V DC shall be applied for 60s between the terminal and the core. | 100Mor more. 100V DC shall be applied between the terminal and the core. | L: within10% | L: within10% | L: within10% | L: within10% | 2000 ppm/or less | -40 ~ + 125 | -40 ~ + 85 |
| GCRH127M | GCRH127M-330MC | 33 | 100KHz/0.25V | 70 | 6.22 | L: within10% | L: within10% | L: within10% | Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes. | The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes. | 90% minimum of the surface immersed. | L: within10% | Without damage. 100V DC shall be applied for 60s between the terminal and the core. | 100Mor more. 100V DC shall be applied between the terminal and the core. | L: within10% | L: within10% | L: within10% | L: within10% | 2000 ppm/or less | -40 ~ + 125 | -40 ~ + 85 |
| GCRH127M | GCRH127M-390MC | 39 | 100KHz/0.25V | 75 | 4.50 | L: within10% | L: within10% | L: within10% | Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes. | The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes. | 90% minimum of the surface immersed. | L: within10% | Without damage. 100V DC shall be applied for 60s between the terminal and the core. | 100Mor more. 100V DC shall be applied between the terminal and the core. | L: within10% | L: within10% | L: within10% | L: within10% | 2000 ppm/or less | -40 ~ + 125 | -40 ~ + 85 |
| GCRH127M | GCRH127M-470MC | 47 | 100KHz/0.25V | 80 | 5.28 | L: within10% | L: within10% | L: within10% | Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes. | The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes. | 90% minimum of the surface immersed. | L: within10% | Without damage. 100V DC shall be applied for 60s between the terminal and the core. | 100Mor more. 100V DC shall be applied between the terminal and the core. | L: within10% | L: within10% | L: within10% | L: within10% | 2000 ppm/or less | -40 ~ + 125 | -40 ~ + 85 |
| GCRH127M | GCRH127M-560MC | 56 | 100KHz/0.25V | 130 | 4.50 | L: within10% | L: within10% | L: within10% | Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes. | The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes. | 90% minimum of the surface immersed. | L: within10% | Without damage. 100V DC shall be applied for 60s between the terminal and the core. | 100Mor more. 100V DC shall be applied between the terminal and the core. | L: within10% | L: within10% | L: within10% | L: within10% | 2000 ppm/or less | -40 ~ + 125 | -40 ~ + 85 |
| GCRH127M | GCRH127M-680MC | 68 | 100KHz/0.25V | 105 | 4.26 | L: within10% | L: within10% | L: within10% | Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes. | The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes. | 90% minimum of the surface immersed. | L: within10% | Without damage. 100V DC shall be applied for 60s between the terminal and the core. | 100Mor more. 100V DC shall be applied between the terminal and the core. | L: within10% | L: within10% | L: within10% | L: within10% | 2000 ppm/or less | -40 ~ + 125 | -40 ~ + 85 |
| GCRH127M | GCRH127M-820MC | 82 | 100KHz/0.25V | 143 | 3.80 | L: within10% | L: within10% | L: within10% | Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes. | The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes. | 90% minimum of the surface immersed. | L: within10% | Without damage. 100V DC shall be applied for 60s between the terminal and the core. | 100Mor more. 100V DC shall be applied between the terminal and the core. | L: within10% | L: within10% | L: within10% | L: within10% | 2000 ppm/or less | -40 ~ + 125 | -40 ~ + 85 |
| GCRH127M | GCRH127M-101MC | 100 | 100KHz/0.25V | 163 | 3.52 | L: within10% | L: within10% | L: within10% | Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes. | The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes. | 90% minimum of the surface immersed. | L: within10% | Without damage. 100V DC shall be applied for 60s between the terminal and the core. | 100Mor more. 100V DC shall be applied between the terminal and the core. | L: within10% | L: within10% | L: within10% | L: within10% | 2000 ppm/or less | -40 ~ + 125 | -40 ~ + 85 |
| GCRH127M | GCRH127M-121MC | 120 | 100KHz/0.25V | 170 | 1.90 | L: within10% | L: within10% | L: within10% | Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes. | The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes. | 90% minimum of the surface immersed. | L: within10% | Without damage. 100V DC shall be applied for 60s between the terminal and the core. | 100Mor more. 100V DC shall be applied between the terminal and the core. | L: within10% | L: within10% | L: within10% | L: within10% | 2000 ppm/or less | -40 ~ + 125 | -40 ~ + 85 |
| GCRH127M | GCRH127M-151MC | 150 | 100KHz/0.25V | 247 | 3.01 | L: within10% | L: within10% | L: within10% | Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes. | The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes. | 90% minimum of the surface immersed. | L: within10% | Without damage. 100V DC shall be applied for 60s between the terminal and the core. | 100Mor more. 100V DC shall be applied between the terminal and the core. | L: within10% | L: within10% | L: within10% | L: within10% | 2000 ppm/or less | -40 ~ + 125 | -40 ~ + 85 |
| GCRH127M | GCRH127M-221MC | 220 | 100KHz/0.25V | 376 | 2.36 | L: within10% | L: within10% | L: within10% | Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes. | The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes. | 90% minimum of the surface immersed. | L: within10% | Without damage. 100V DC shall be applied for 60s between the terminal and the core. | 100Mor more. 100V DC shall be applied between the terminal and the core. | L: within10% | L: within10% | L: within10% | L: within10% | 2000 ppm/or less | -40 ~ + 125 | -40 ~ + 85 |
| GCRH127M | GCRH127M-331MC | 330 | 100KHz/0.25V | 574 | 2.00 | L: within10% | L: within10% | L: within10% | Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes. | The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes. | 90% minimum of the surface immersed. | L: within10% | Without damage. 100V DC shall be applied for 60s between the terminal and the core. | 100Mor more. 100V DC shall be applied between the terminal and the core. | L: within10% | L: within10% | L: within10% | L: within10% | 2000 ppm/or less | -40 ~ + 125 | -40 ~ + 85 |
| GCRH127M | GCRH127M-391MC | 390 | 100KHz/0.25V | 650 | 1.50 | L: within10% | L: within10% | L: within10% | Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes. | The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes. | 90% minimum of the surface immersed. | L: within10% | Without damage. 100V DC shall be applied for 60s between the terminal and the core. | 100Mor more. 100V DC shall be applied between the terminal and the core. | L: within10% | L: within10% | L: within10% | L: within10% | 2000 ppm/or less | -40 ~ + 125 | -40 ~ + 85 |
| GCRH127M | GCRH127M-471MC | 470 | 100KHz/0.25V | 861 | 1.64 | L: within10% | L: within10% | L: within10% | Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes. | The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes. | 90% minimum of the surface immersed. | L: within10% | Without damage. 100V DC shall be applied for 60s between the terminal and the core. | 100Mor more. 100V DC shall be applied between the terminal and the core. | L: within10% | L: within10% | L: within10% | L: within10% | 2000 ppm/or less | -40 ~ + 125 | -40 ~ + 85 |
| GCRH127M | GCRH127M-681MC | 680 | 100KHz/0.25V | 1080 | 1.38 | L: within10% | L: within10% | L: within10% | Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes. | The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes. | 90% minimum of the surface immersed. | L: within10% | Without damage. 100V DC shall be applied for 60s between the terminal and the core. | 100Mor more. 100V DC shall be applied between the terminal and the core. | L: within10% | L: within10% | L: within10% | L: within10% | 2000 ppm/or less | -40 ~ + 125 | -40 ~ + 85 |
| GCRH127M | GCRH127M-821MC | 820 | 100KHz/0.25V | 1470 | 1.26 | L: within10% | L: within10% | L: within10% | Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes. | The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes. | 90% minimum of the surface immersed. | L: within10% | Without damage. 100V DC shall be applied for 60s between the terminal and the core. | 100Mor more. 100V DC shall be applied between the terminal and the core. | L: within10% | L: within10% | L: within10% | L: within10% | 2000 ppm/or less | -40 ~ + 125 | -40 ~ + 85 |
| GCRH127M | GCRH127M-102MC | 1000 | 100KHz/0.25V | 1660 | 1.14 | L: within10% | L: within10% | L: within10% | Peak acceleration: 981 m/S2 Duration of pulse: 6ms 3 times in each of 3(X,Y,Z)axes. | The specimen must be fixed on test board. It must be equipped with instruments of which weight is 500g. Then it shall be fallen freely from 1m height to rigid wood 3 times in each of three axes. | 90% minimum of the surface immersed. | L: within10% | Without damage. 100V DC shall be applied for 60s between the terminal and the core. | 100Mor more. 100V DC shall be applied between the terminal and the core. | L: within10% | L: within10% | L: within10% | L: within10% | 2000 ppm/or less | -40 ~ + 125 | -40 ~ + 85 |
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Beijing Silk Road Enterprise Management Services Co., Ltd.
Location
16 Floor, Unit B, Jiatai International Mansion, No 41, Dongsihuan Zhong Road, Chaoyang District, Beijing
Contact Person
Sellina