Product Overview
ALUMINUM SOLID CAPACITORS - PB series are long-life products designed for operation at 105 with a lifespan of 5000 to 10000 hours. They offer a wide operating temperature range from -55 to +105 and are available in various rated voltages from 6.3V to 250V and rated capacitance from 1F to 2700F.
Product Attributes
- Series: PB series
- Capacitor Type: Aluminum Solid Capacitors
- Features: Long-life Products
- Operating Temperature: 105
- Lifespan: 5000~10000Hrs
Technical Specifications
| Rated Voltage (V) | Rated Capacitance (F) | Capacitance Tolerance (120Hz,20) | Leakage Current (LC) (A,2min) | Endurance (105) | Moisture Resistance (60C, RH90~95%, 1000H) | ESR (m,100KHz) | Dissipation Factor (tan ) (120Hz,20) | Rated Ripple Current (mA,105,100KHz) | Dimensions DxL(mm) | Part Number |
| 6.3 | 1000 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 10 | 6 | 4500 | 6.3X12 | PB6.3V1000M6X12 |
| 6.3 | 1500 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 10 | 6 | 4700 | 8X11.5 | PB6.3V1500M8X11 |
| 6.3 | 1800 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 10 | 6 | 5000 | 10X12.5 | PB6.3V1800M10X12 |
| 10 | 330 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 15 | 4300 | 8X8 | PB10V330M8X8 |
| 10 | 470 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 13 | 4500 | 8X11.5 | PB10V470M8X11 |
| 10 | 680 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 13 | 4500 | 8X11.5 | PB10V680M8X11 |
| 10 | 1000 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 13 | 4900 | 10X11.5 | PB10V1000M10X11 |
| 16 | 220 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 20 | 3500 | 6.3X8 | PB16V220M6X8 |
| 16 | 220 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 16 | 4300 | 8X8 | PB16V220M8X8 |
| 16 | 270 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 16 | 4300 | 8X8 | PB16V270M8X8 |
| 16 | 270 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 16 | 4500 | 8X11.5 | PB16V270M8X11 |
| 16 | 330 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 16 | 4100 | 6X11 | PB16V330M6X11 |
| 16 | 330 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 16 | 4500 | 8X11.5 | PB16V330M8X11 |
| 16 | 470 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 16 | 4100 | 6.3X11.5 | PB16V470M6X11 |
| 16 | 470 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 16 | 4500 | 8X11.5 | PB16V470M8X11 |
| 16 | 560 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 16 | 4500 | 6.3X14 | PB16V560M6X14 |
| 16 | 680 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 14 | 4900 | 10X12.5 | PB16V680M10X12 |
| 16 | 820 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 16 | 4500 | 8X12.5 | PB16V820M8X12 |
| 16 | 820 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 14 | 4900 | 10X12.5 | PB16V820M10X12 |
| 16 | 1000 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 16 | 4500 | 8X15 | PB16V1000M8X15 |
| 16 | 1000 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 16 | 4800 | 10X11.5 | PB16V1000M10X11 |
| 16 | 1000 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 14 | 5100 | 10X15 | PB16V1000M10X15 |
| 16 | 2200 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 14 | 5100 | 10X15 | PB16V2200M10X15 |
| 25 | 100 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 25 | 2900 | 6.3X8 | PB25V100M6X8 |
| 25 | 220 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 20 | 3500 | 6.3X12 | PB25V220M6X12 |
| 25 | 220 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 16 | 4100 | 8X11 | PB25V220M8X11 |
| 25 | 270 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 25 | 3500 | 6.3X12 | PB25V270M6X12 |
| 25 | 330 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 16 | 4500 | 8X11.5 | PB25V330M8X11 |
| 25 | 470 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 16 | 4100 | 8X11 | PB25V470M8X11 |
| 25 | 560 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 14 | 4700 | 10X12.5 | PB25V560M10X12 |
| 25 | 680 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 14 | 4900 | 10X15 | PB25V680M10X15 |
| 25 | 820 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 10 | 16 | 4100 | 8X15 | PB25V820M8X15 |
| 25 | 1000 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 16 | 4500 | 10X15 | PB25V1000M10X15 |
| 25 | 1000 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 16 | 4500 | 8X16 | PB25V1000M8X17 |
| 35 | 100 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 28 | 2600 | 6.3X8 | PB35V100M6X8 |
| 35 | 220 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 18 | 2980 | 6X12 | PB35V220M6X12 |
| 35 | 330 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 14 | 4700 | 10X12.5 | PB35V330M10X12 |
| 35 | 470 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 16 | 3800 | 8X15 | PB35V470M8X15 |
| 35 | 470 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 14 | 4900 | 10X15 | PB35V470M10X15 |
| 35 | 680 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 8 | 16 | 4100 | 10X15 | PB35V680M10X15 |
| 160 | 4.7 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 130 | 12 | 1000 | 8X11.5 | PB160V4R7M8X11 |
| 160 | 12 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 130 | 12 | 1000 | 8X11.5 | PB160V12M8X11 |
| 200 | 1 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 300 | 15 | 600 | 8X11.5 | PB200V1M8X11 |
| 200 | 2.2 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 300 | 15 | 600 | 10X12.5 | PB200V2R2M10X12 |
| 250 | 1 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 300 | 15 | 600 | 8X11.5 | PB250V1M8X11 |
| 250 | 2.2 | 20% | 0.2CV or 500A (whichever is greater) | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | Capacitance Change: 20% of initial value Leakage Current: Within initial specified value ESR: 150% of initial standard value Dissipation Factor: 150% of initial standard value | 300 | 15 | 600 | 10X12.5 | PB250V2R2M10X12 |