Product Overview

This datasheet specifies the Kaiyuexiang Electronics Co., Ltd. Quartz Crystal Resonator, model 1612/32.000MHZ. It is designed for electronic applications requiring precise frequency control. Key parameters include a frequency of 32.000 MHz and a load capacitance of 8 PF with a frequency tolerance of 30ppm at 253.

Product Attributes

  • Brand: Kaiyuexiang
  • Origin: Shenzhen, China
  • Product Name: Quartz Crystal Resonator
  • Product Model: 1612/32.000MHZ
  • Original Model: K16320000830
  • Marking: KYX32.000

Technical Specifications

ParameterValueUnitCondition
Frequency32.000MHZ-
Holder TypeSMD1.6*1.2--
Frequency Tolerance30ppmat 253
Equivalent Series Resistance40Max
Storage Temperature Range-40 to +85-
Operating Temperature Range-40 to +85-
Frequency Characteristics Over Temperature20ppm-40+85
Load Capacitance (CL)8PF-
Drive Level100W-
Shunt Capacitance5PFMAX
Insulation Resistance500MMin at 100 V
Mode Of OscillationFundamental--
Aging3ppm/Year-
Dimensions(Not specified in detail)mm-

Reliability Testing

Test ItemConditions and RequirementsRequirements
VibrationFrequency sweep from 10Hz to 55Hz and back to 10Hz at 1 octave/min. Amplitude: 1.5mm. Applied for 2h each on 3 mutually perpendicular axes (total 6h).(1).FL:+/-10ppm (2).Rr:+/-10
DropFrom 70cm height onto 3cm hard wooden floor, 3 times.-
ShockPeak acceleration: 981m/s, pulse duration: 6ms. Three successive shocks applied in both directions of 3 mutually perpendicular axes (total 18 shocks).(1).FL:+/-10ppm (2).Rr:+/-10
Damp heat, constantStored at 402 with 90%-95% relative humidity for 48h, then subjected to standard atmospheric conditions for 1-2h before measurement.-
Cold storageStored at -405 for 48h, then subjected to standard atmospheric conditions for 1-2h before measurement.-
Dry heat storageStored at 1005 for 24h, then subjected to standard atmospheric conditions for 1-2h before measurement.-
AgingStored at 855 for 7 days, then subjected to standard atmospheric conditions for 1-2h before measurement.-
Temperature cycling5 successive cycles with parameters: -403 for 30min, standard atmospheric conditions within 30s, 1003 for 30min, standard atmospheric conditions within 30s. Then subjected to standard atmospheric conditions for 1-2h before measurement.-
Resistance to soldering heat(Details not provided)-

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Beijing Silk Road Enterprise Management Services Co., Ltd.
Location 16 Floor, Unit B, Jiatai International Mansion, No 41, Dongsihuan Zhong Road, Chaoyang District, Beijing
Contact Person Sellina

Request A Quote

Please check your email address.
Your message must be at least 20 characters.