Aluminum Electrolytic Capacitors With Vinyl Sleeve And Rubber Seal Man Yue Tech EGT827M1HI20CS Model

Price Negotiable
Price: Negotiable
MOQ: Negotiable
Delivery Time: Negotiable
Product Description

Product Overview

This specification applies to polar Aluminum electrolytic capacitors (foil type) designed for use in electronic equipment. These capacitors are constructed with a single-ended type, featuring terminals fixed to anode and cathode foil, wound together with paper, and impregnated with electrolyte. The wound element is enclosed in an aluminum case, sealed tightly with end seal rubber, and finished with a vinyl sleeve. The capacitors are designed to meet IEC60384 standards.

Product Attributes

  • Brand: SAMXON
  • Series: GT SERIES
  • Construction Type: Single ended, foil type
  • Case Material: Aluminum
  • Sleeve Material: PET
  • Separator Material: Electrolyte paper
  • Lead Line Material: Tinned CP wire (Pb Free)
  • Terminal Material: Aluminum wire
  • Sealing Material: Rubber
  • Origin: MAN YUE ELECTRONICS COMPANY LIMITED

Technical Specifications

Part Number WV (Vdc) Cap. (F) Cap. tolerance Temp. range() tan (120Hz, 20) Leakage Current (A, 2min) Max Ripple Current at 105 100KHz (mA rms) Impedance at 20 100KHz max Load lifetime (Hrs) Dimension (mm) DL Sleeve F d
EGT827M1HI20CS**P 50 820 -20%~+20% -40~105 0.10 410 1660 0.045 10000 12.5X20 5.0 0.6

General Characteristics

Item Description
Rated voltage (WV) 6.3, 10, 16, 25, 35, 50, 63, 100 V.DC
Surge voltage (SV) 8, 13, 20, 32, 44, 63, 79, 125 V.DC
Nominal capacitance measurement condition Measuring Frequency: 120Hz12Hz, Measuring Voltage: Not more than 0.5Vrms, Measuring Temperature: 202
Leakage current condition Capacitor connected with a protective resistor (1k 10 ) in series for 2 minutes, then measure Leakage Current.
tan condition See 4.2, Norm Capacitance, for measuring frequency, voltage and temperature.
Terminal strength condition Tensile Strength: Applied force to the terminal in lead out direction for 101 seconds. Bending Strength: Applied force to bent the terminal (1~4 mm from the rubber) for 90o within 2~3 seconds, and then bent it for 90o to its original position within 2~3 seconds.
Terminal strength criteria No noticeable changes, no breakage or looseness at the terminal.
Temperature characteristic steps 1. 202 (Time to reach thermal equilibrium)
2. -40(-25) 3 (Time to reach thermal equilibrium)
3. 202 (Time to reach thermal equilibrium)
4. 1052 (Time to reach thermal equilibrium)
5. 202 (Time to reach thermal equilibrium)
Load life test condition According to IEC60384-4No.4.13 methods, stored at 105C 2 with DC bias voltage plus the rated ripple current for Table 1. (Sum of DC and ripple peak voltage shall not exceed rated working voltage). Tested after 16 hours recovering time at atmospheric conditions.
Load life test criteria Leakage current: Satisfied in 4.3. Capacitance Change: Within 25% of initial value. tan: Not more than 200% of specified value. Appearance: No electrolyte leakage.
Shelf life test condition Stored with no voltage applied at 1052 for 1000+48/0 hours. Stabilized at room temperature for 4~8 hours. Connected to a series limiting resistor (1k100 ) with D.C. rated voltage applied for 30min. Discharged, then tested characteristics.
Shelf life test criteria Leakage current: Satisfied in 4.3. Capacitance Change: Within 25% of initial value. tan: Not more than 200% of specified value. Appearance: No electrolyte leakage.
Surge test condition Applied a surge voltage to the capacitor connected with a (100 50)/CR (k) resistor. 1000 cycles, each consisting of charge of 30 5s, followed discharge of 5 min 30s. Test temperature: 15~35. CR: Nominal Capacitance ( F)
Surge test criteria Leakage current: Not more than specified value. Capacitance Change: Within 15% of initial value. tan: Not more than specified value. Appearance: No electrolyte leakage.
Vibration test condition 10Hz ~ 55Hz, Peak to peak amplitude: 1.5mm, Sweep rate: 10Hz ~ 55Hz ~ 10Hz in about 1 minute, for 2 hours in each of 3 mutually perpendicular directions. Mounting method: Capacitors with diameter > 12.5mm or length > 25mm must be fixed with a bracket.
Vibration test criteria Inner construction: No intermittent contacts, open or short circuiting. No damage of tab terminals or electrodes. Appearance: No mechanical damage in terminal. No leakage of electrolyte or swelling of the case. Markings legible.
Solderability test condition Sn-Cu solder, Soldering temperature: 2503C, Dipping depth: 2mm, Dipping speed: 252.5mm/s, Dipping time: 30.5s
Solderability test criteria Coating quality: A minimum of 95% of the surface being immersed.
Resistance to solder heat test condition Terminals immersed into solder bath at 2605 for 10 1seconds or 40010 for 3 0 1 seconds to 1.5~2.0mm from the body of capacitor. Left under normal temperature and humidity for 1~2 hours before measurement.
Resistance to solder heat test criteria Leakage current: Not more than specified value. Capacitance Change: Within 10% of initial value. tan: Not more than specified value. Appearance: No electrolyte leakage.
Change of temperature test condition Temperature Cycle: According to IEC60384-4No.4.7 methods. 1 cycle: (1)+20 3 Minutes, (2)Rated low temperature (-40 or -25) 302 Minutes, (3)Rated high temperature (+105) 302 Minutes. Total 5 cycles.
Change of temperature test criteria Leakage current: Not more than specified value. tan: Not more than specified value. Appearance: No electrolyte leakage.
Damp heat test condition According to IEC60384-4No.4.12 methods. Exposed for 5008 hours in an atmosphere of 90~95% R H .at 402.
Damp heat test criteria Leakage current: Not more than specified value. Capacitance Change: Within 20% of initial value. tan: Not more than 120% of specified value. Appearance: No electrolyte leakage.
Vent test condition Applies to products with vent, diameter 6.3mm. DC test: Capacitor connected with polarity reversed to a DC power source. Current applied from Table 3.
Vent test criteria The vent shall operate with no dangerous conditions such as flames or dispersion of pieces of the capacitor and/or case.
Maximum permissible (ripple current) condition Maximum A.C current at 120Hz and can be applied at maximum operating temperature. Table-1. Combined value of D.C voltage and the peak A.C voltage shall not exceed rated voltage and shall not reverse voltage.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Beijing Silk Road Enterprise Management Services Co., Ltd.
Location 16 Floor, Unit B, Jiatai International Mansion, No 41, Dongsihuan Zhong Road, Chaoyang District, Beijing
Contact Person Sellina

Request A Quote

Please check your email address.
Your message must be at least 20 characters.