Beijing Silk Road Enterprise Management Services Co., Ltd.
                                                                                                           
Verified Supplier
17 Years
Since 2009
Menu

aluminum electrolytic capacitor Man Yue Tech ERT686M2WL20CB suitable for electronic equipment applications

Price Negotiable
Price: Negotiable
MOQ: Negotiable
Delivery Time: Negotiable
Product Description

Product Overview

The SAMXON RT Series Aluminum Electrolytic Capacitors are polar, foil-type capacitors designed for use in electronic equipment. They meet IEC60384 standards and are constructed with a single-ended, aluminum case design impregnated with electrolyte and enclosed in a PET sleeve. These capacitors are suitable for applications requiring reliable performance and durability, withstanding lightning strikes up to 4KV.

Product Attributes

  • Brand: SAMXON
  • Series: RT Series
  • Construction: Single ended type, aluminum case, PET sleeve
  • Material: Tinned CP wire (Pb Free) for lead line, Aluminum wire for terminal, Rubber for sealing, Formed aluminum foil for anode, Etched or formed aluminum foil for cathode, Aluminum case, PET sleeve, Electrolyte paper separator.
  • Certifications/Standards: IEC60384

Technical Specifications

SAMXON Part No. WV (Vdc) Cap. (F) Cap. tolerance Temp. range() tan (120Hz, 20) Leakage Current (A, 2min) Max Ripple Current at 105 100 kHz (mA rms) ESR at 25 100kHz () Load lifetime (Hrs) Dimension (mm) DL Dimension (mm) F Dimension (mm) d
ERT686M2WL20CBA15 450 68 -20%~+20% -25~105 0.20 637 1230 0.9 5000 18X20 7.5 0.8

Key Performance Characteristics

Item Description
4.1 Rated voltage (WV) & Surge voltage (SV) WV (V.DC): 160, 200, 220, 250, 350, 400, 420, 450, 500
SV (V.DC): 200, 250, 270, 300, 400, 450, 470, 500, 550
4.2 Nominal capacitance (Tolerance) Condition: Measuring Frequency: 120Hz12Hz, Measuring Voltage: Not more than 0.5Vrms, Measuring Temperature: 202
Criteria: Shall be within the specified capacitance tolerance.
4.3 Leakage current Condition: Connected with a protective resistor (1k 10) in series for 2 minutes, then measure.
Criteria: Refer to Table 1.
4.4 tan Condition: See 4.2 for measuring frequency, voltage and temperature.
Criteria: Refer to Table 1.
4.5 Terminal strength Condition: Tensile and Bending Strength tests applied to terminals.
Criteria: No noticeable changes, breakage, or looseness at the terminal.
4.6 Temperature characteristics Condition: Step testing at various temperatures (-40 to 105).
Criteria: tan within limits, leakage current not exceeding specified values, impedance ratio at -25 within table limits.
4.7 Load life test Condition: 105C 2 with DC bias voltage plus rated ripple current for Table 1, for specified duration.
Criteria: Leakage current satisfied, Capacitance Change within 20%, tan not more than 200%, no electrolyte leakage.
4.8 Shelf life test Condition: Stored at 1052 for 1000+48/0 hours, then tested.
Criteria: Leakage current satisfied, Capacitance Change within 20%, tan not more than 200%, no electrolyte leakage.
4.9 Surge test Condition: Applied surge voltage for 1000 cycles.
Criteria: Leakage current not more than specified, Capacitance Change within 15%, tan not more than specified, no electrolyte leakage.
4.10 Vibration test Condition: 10Hz ~ 55Hz, 1.5mm peak to peak amplitude for 2 hours in 3 directions.
Criteria: No intermittent contacts, open/short circuits, damage to terminals or electrodes, or leakage/swelling. Markings legible.
4.11 Solderability test Condition: Sn-Cu solder at 2503, 2mm dipping depth, 252.5mm/s dipping speed, 30.5s dipping time.
Criteria: Minimum 95% of the surface immersed with good coating quality.
4.12 Resistance to solder heat test Condition: Immersion in solder bath at 2605 for 101 seconds or 40010 for 3+0/-1 seconds.
Criteria: Leakage current not more than specified, Capacitance Change within 10%, tan not more than specified, no electrolyte leakage.
4.13 Change of temperature test Condition: Temperature cycling (-40 to +105) for 5 cycles.
Criteria: Leakage current not more than specified, tan not more than specified, no electrolyte leakage.
4.14 Damp heat test Condition: 90~95% RH at 402 for 5008 hours.
Criteria: Leakage current not more than specified, Capacitance Change within 20%, tan not more than 120%, no electrolyte leakage.
4.15 Vent test Condition: DC test with reversed polarity and applied current based on diameter.
Criteria: Vent operates with no dangerous conditions (flames, dispersion of pieces).
4.16 Maximum permissible (ripple current) Condition: Maximum AC current at 120Hz and maximum operating temperature. Frequency multipliers provided for different frequencies. Temperature coefficients provided for different temperatures.

Product Marking

Capacitors are marked with: Nominal capacitance, Rated voltage, Series symbol (RT), Tolerance (M), Polarity (Cathode marked with black stripe and '-'), Trademark (SAMXON), Maximum operating temperature (105C), Sleeve material (H), and Date code (Year, Month, Series No.).

Environment-related Substances

This section refers to the latest document of Environment-related Substances standard (WI-HSPM-QA-072) and lists controlled substances including Heavy metals, Chlorinated organic compounds, Brominated organic compounds, and others.

Application Guidelines

1. Circuit Design: Considers effects of operating temperature and frequency on electrical parameters. Avoids misapplication conditions like reverse voltage, over voltage, and excessive ripple current. Provides guidelines for series/parallel capacitor usage and mounting considerations including clearance for pressure relief vents and circuit board pattern design. Emphasizes electrical isolation and safety precautions.

2. Capacitor Handling Techniques: Includes considerations before use (finite life, transient recovery voltage, leakage current increase with storage, avoiding dropped or dented capacitors), insertion (verifying capacitance, voltage, polarity, hole spacing), soldering (manual and flow soldering specifications), and post-solder handling. Also covers circuit board cleaning and mounting adhesives.

3. Precautions for using capacitors: Advises against storing or using capacitors in extreme temperatures, direct contact with water/oil, high humidity, toxic gases, ozone, radiation, or excessive vibration/shock. Includes electrical precautions regarding terminal contact and short circuits.

4. Emergency Procedures: Outlines immediate actions if the pressure relief vent operates, including turning off equipment, avoiding contact with escaping electrolyte gas, and first aid measures for eye, mouth, or skin contact.

5. Long Term Storage: Notes that leakage current increases with long storage times and recommends reconditioning by applying rated voltage in series with a current limiting resistor. Products over eighteen months old should be returned for confirmation.

6. Capacitor Disposal: Recommends incineration after crushing or puncturing to prevent explosion, or disposal as solid waste, adhering to local laws.


Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Beijing Silk Road Enterprise Management Services Co., Ltd.
Location 16 Floor, Unit B, Jiatai International Mansion, No 41, Dongsihuan Zhong Road, Chaoyang District, Beijing
Contact Person Sellina

Request A Quote

Please check your email address.
Your message must be at least 20 characters.