Product Overview

This document specifies the Sorede SBCM.9070.YF series common mode chokes. It details the product structure, electrical characteristics, material list, packaging, and reliability test results. This product is designed for applications requiring effective noise suppression.

Product Attributes

  • Brand: Sorede
  • Origin: Shenzhen, China
  • Certifications: UL File No. (for wire material)

Technical Specifications

Part NumberImpedance (@100MHz) MinImpedance (@100MHz) TypDCR (m) max.Rated Current (A)MaxRated Volt. (Vdc)maxIR (M) min.MARK
SBCM.9070.YF301TT00225300668010301
SBCM.9070.YF501TT0045060085.58010501
SBCM.9070.YF701TT005007001058010701
SBCM.9070.YF102TT0075010001348010102
SBCM.9070.YF222TT00170022005038010222
SBCM.9070.YF272TT00200027008028010272
SBCM.9070.YF302TT00250030008028010302
ItemSpecificationsTest Methods
Solder- AbilityMore than 90% of termination should be covered with new solder.Solder: Sn, Temperature: 255+5/-0, Flux: rosin, Duration: 3.50.5s
Leaching ResistanceMore than 75% of termination Should be covered with new solder.Solder: Sn, Temperature: 270+2/-0, Flux: rosin, Duration: 100.5s
DropNo mechanical damage shall be noticed Impedance shall be within 20% of the initial valueDrop 10 times on a concrete floor from a height of 1m.
Vibration-Frequency: 10 to 55Hz, Amplitude: 1.52mm, Direction and time: X, Y and Z directions for 2 hours each.
Humidity resistancea. Test condition: Temp. 405, Humidity: 90%~95%, Test time: 50012hr. b. Measurement method: The component should be stabilized at normal condition for 24 hours before test.-
High temperature resistancea. Test condition: Applied rated current, Temp. 855, Test time: 50012hr. b. Measurement method: The component should be stabilized at normal condition for 24 hours before test.-
Low temperature resistanceNo mechanical damage shall be noticed Impedance shall be within 20% of the initial valuea. Test condition: Temp. -405, Test time: 50012hr. b. Measurement method: The component should be stabilized at normal condition for 24 hours before test.
Thermal shocka. Test condition: 1) Temp. -40, time: 303min 2) Temp. +85, time: 303min, 100 cycles b. Measurement method: The component should be stabilized at normal condition for 24 hours before test.-

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Beijing Silk Road Enterprise Management Services Co., Ltd.
Location 16 Floor, Unit B, Jiatai International Mansion, No 41, Dongsihuan Zhong Road, Chaoyang District, Beijing
Contact Person Sellina

Request A Quote

Please check your email address.
Your message must be at least 20 characters.