Beijing Silk Road Enterprise Management Services Co., Ltd.
                                                                                                           
Verified Supplier
17 Years
Since 2009
Menu

High current shielded composite inductor Vishay IHLP1616ABERR47M11 low DCR series for POL converters

Price Negotiable
Price: Negotiable
MOQ: Negotiable
Delivery Time: Negotiable
Product Description

Vishay IHLP Commercial Inductors, Low DCR Series

The Vishay IHLP-1616AB-11 series offers shielded construction and the lowest DCR/H in its package size, making it ideal for high-current applications. These inductors handle high transient current spikes without saturation and exhibit ultra-low buzz noise due to their composite construction. They provide excellent DC/DC energy storage up to 1.0 MHz to 2.0 MHz and are suitable for filter inductor applications up to SRF. Key applications include PDA, notebook, desktop, server, high current POL converters, low profile power supplies, battery-powered devices, and DC/DC converters in distributed power systems and for FPGAs.

Product Attributes

  • Brand: Vishay Dale
  • Product Family: IHLP
  • Series: Commercial Inductors, Low DCR Series
  • Construction: Shielded
  • Material: Composite
  • Certifications: LEAD (Pb)-FREE STANDARD
  • Patent(s): Covered by US and international patents

Technical Specifications

Model Inductance (H) Inductance Tolerance DCR Typ. (m) @ 25 C DCR Max. (m) @ 25 C Heat Rating Current DC Typ. (A) (1) Saturation Current DC Typ. (A) (2) SRF Typ. (MHz)
IHLP-1616AB-11 0.10 0.10 20 % 5.0 5.5 12.0 12.0 288
IHLP-1616AB-11 0.22 0.22 20 % 9.5 10.5 9.5 9.5 214
IHLP-1616AB-11 0.47 0.47 20 % 19.0 21.0 6.0 5.7 117
IHLP-1616AB-11 1.0 1.0 20 % 43.0 47.0 4.2 4.5 71
IHLP-1616AB-11 1.2 1.2 20 % 55.6 58.5 3.75 3.75 62
IHLP-1616AB-11 1.5 1.5 20 % 68.0 75.0 3.25 3.25 53
IHLP-1616AB-11 2.2 2.2 20 % 79.4 83.5 2.75 3.00 49

Notes:
All test data is referenced to 25 C ambient.
Operating temperature range -55 C to +125 C.
The part temperature (ambient + temp. rise) should not exceed 125 C under worst case operating conditions.
Rated operating voltage (across inductor) = 40 V (1)
(1) DC current (A) that will cause an approximate T of 40 C.
(2) DC current (A) that will cause L0 to drop approximately 20 %.

Dimensions: (Refer to datasheet for detailed diagrams)

Part Numbering Scheme: IHLP-1616AB-11 2.2 H 20 % ER e3


Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Beijing Silk Road Enterprise Management Services Co., Ltd.
Location 16 Floor, Unit B, Jiatai International Mansion, No 41, Dongsihuan Zhong Road, Chaoyang District, Beijing
Contact Person Sellina

Request A Quote

Please check your email address.
Your message must be at least 20 characters.