Industrial power wirewound resistor molded welded chassis mount VISHAY RH02510R00FE02 with non inductive option
Vishay Dale Wirewound Resistors, Industrial Power, Aluminum Housed, Chassis Mount
These industrial power wirewound resistors are designed for chassis mounting, utilizing the heat-sink effect for efficient thermal management. Featuring a molded construction for total environmental protection and complete welded construction, they offer excellent stability in operation with less than 1% change in resistance. Available in standard (RH) and non-inductive (NH) styles, they meet applicable requirements of MIL-PRF-18546 and are suitable for demanding industrial applications.
Product Attributes
- Brand: Vishay Dale
- Construction: Molded, Welded
- Certifications: Meets applicable requirements of MIL-PRF-18546
- Non-Inductive Option: Available (Type NH) with Ayrton-Perry winding
- Mounting: Chassis Mount
- Material Compliance: Refer to www.vishay.com/doc?99912 for definitions
Technical Specifications
| Global Model | Historical Model | Power Rating (P25C) W | Resistance Range ( 0.05 %, 0.1 %) | Resistance Range ( 0.25 %) | Resistance Range ( 0.5 %) | Resistance Range ( 1 %, 3 %, 5 %) | Weight (typical) g | Temperature Coefficient ppm/C | Maximum Working Voltage V (P x R)1/2 | Insulation Resistance | Solderability |
| RH005 | RH-5 | 7.5 | 0.5 to 6.75K | 0.1 to 8.6K | 0.05 to 8.6K | 0.02 to 24.5K | 3 | 20 for 10 and above; 50 for 1 to 9.9 , 100 for 0.1 to 0.99 | (P x R)1/2 | 10 000 M minimum dry, 1000 M minimum after moisture test | Meets requirements of ANSI J-STD-002 |
| NH005 | NH-5 | 7.5 | 0.5 to 2.32K | 0.1 to 3.27K | 0.05 to 3.27K | 0.05 to 12.75K | 3 | 20 for 10 and above; 50 for 1 to 9.9 , 100 for 0.1 to 0.99 | (P x R)1/2 | 10 000 M minimum dry, 1000 M minimum after moisture test | Meets requirements of ANSI J-STD-002 |
| RH010 | RH-10 | 12.5 | 0.5 to 12.7K | 0.1 to 16.69K | 0.05 to 16.69K | 0.01 to 47.1K | 5 | 20 for 10 and above; 50 for 1 to 9.9 , 100 for 0.1 to 0.99 | (P x R)1/2 | 10 000 M minimum dry, 1000 M minimum after moisture test | Meets requirements of ANSI J-STD-002 |
| NH010 | NH-10 | 12.5 | 0.5 to 4.45K | 0.1 to 5.54K | 0.05 to 5.54K | 0.05 to 23.5K | 5 | 20 for 10 and above; 50 for 1 to 9.9 , 100 for 0.1 to 0.99 | (P x R)1/2 | 10 000 M minimum dry, 1000 M minimum after moisture test | Meets requirements of ANSI J-STD-002 |
| RH025 | RH-25 | 25 | 0.5 to 25.7K | 0.1 to 32.99K | 0.05 to 32.99K | 0.01 to 95.2K | 12 | 20 for 10 and above; 50 for 1 to 9.9 , 100 for 0.1 to 0.99 | (P x R)1/2 | 10 000 M minimum dry, 1000 M minimum after moisture test | Meets requirements of ANSI J-STD-002 |
| NH025 | NH-25 | 25 | 0.5 to 9.09K | 0.1 to 12.8K | 0.05 to 12.8K | 0.05 to 47.6K | 12 | 20 for 10 and above; 50 for 1 to 9.9 , 100 for 0.1 to 0.99 | (P x R)1/2 | 10 000 M minimum dry, 1000 M minimum after moisture test | Meets requirements of ANSI J-STD-002 |
| RH050 | RH-50 | 50 | 0.5 to 73.4K | 0.1 to 96K | 0.05 to 96K | 0.01 to 273K | 28 | 20 for 10 and above; 50 for 1 to 9.9 , 100 for 0.1 to 0.99 | (P x R)1/2 | 10 000 M minimum dry, 1000 M minimum after moisture test | Meets requirements of ANSI J-STD-002 |
| NH050 | NH-50 | 50 | 0.5 to 26K | 0.1 to 36.7K | 0.05 to 36.7K | 0.05 to 136K | 28 | 20 for 10 and above; 50 for 1 to 9.9 , 100 for 0.1 to 0.99 | (P x R)1/2 | 10 000 M minimum dry, 1000 M minimum after moisture test | Meets requirements of ANSI J-STD-002 |
| RH100 | RH-100 | 100 | 0.5 to 90K | 0.1 to 90K | 0.05 to 90K | 0.05 to 90K | 353 | 20 for 10 and above; 50 for 1 to 9.9 , 100 for 0.1 to 0.99 | (P x R)1/2 | 10 000 M minimum dry, 1000 M minimum after moisture test | Meets requirements of ANSI J-STD-002 |
| NH100 | NH-100 | 100 | 0.5 to 37.5K | 0.1 to 37.5K | 0.05 to 37.5K | 0.05 to 37.5K | 353 | 20 for 10 and above; 50 for 1 to 9.9 , 100 for 0.1 to 0.99 | (P x R)1/2 | 10 000 M minimum dry, 1000 M minimum after moisture test | Meets requirements of ANSI J-STD-002 |
| RH250 | RH-250 | 250 | 0.5 to 116K | 0.1 to 116K | 0.05 to 116K | 0.05 to 116K | 637 | 20 for 10 and above; 50 for 1 to 9.9 , 100 for 0.1 to 0.99 | (P x R)1/2 | 10 000 M minimum dry, 1000 M minimum after moisture test | Meets requirements of ANSI J-STD-002 |
| NH250 | NH-250 | 250 | 0.5 to 48.5K | 0.1 to 48.5K | 0.05 to 48.5K | 0.05 to 48.5K | 637 | 20 for 10 and above; 50 for 1 to 9.9 , 100 for 0.1 to 0.99 | (P x R)1/2 | 10 000 M minimum dry, 1000 M minimum after moisture test | Meets requirements of ANSI J-STD-002 |
Dimensions
| Global Model | A [mm] | B [mm] | C [mm] | D [mm] | E [mm] | F [mm] | G [mm] | H [mm] | J [mm] | K [mm] | L [mm] | M [mm] | N [mm] | P [mm] |
| RH005 NH005 | 11.28 0.127 | 12.45 0.127 | 15.24 0.787 | 28.58 1.57 | 8.48 0.381 | 16.41 0.381 | 8.13 0.381 | 1.65 0.254 | 3.38 0.254 | 1.98 0.254 | 2.36 0.127 | 1.98 0.381 | 1.27 0.127 | 6.76 1.57 |
| RH010 NH010 | 14.27 0.127 | 15.88 0.127 | 19.05 0.787 | 34.93 1.57 | 10.67 0.381 | 20.32 0.381 | 9.91 0.381 | 1.91 0.254 | 4.19 0.254 | 2.36 0.254 | 2.39 0.127 | 2.59 0.381 | 2.16 0.127 | 7.92 1.57 |
| RH025 NH025 | 18.26 0.127 | 19.84 0.127 | 26.97 0.787 | 49.23 1.57 | 13.97 0.381 | 27.43 0.381 | 13.87 0.381 | 1.91 0.254 | 5.87 0.254 | 4.37 0.254 | 3.18 0.127 | 2.92 0.381 | 2.16 0.127 | 11.13 1.57 |
| RH050 NH050 | 39.67 0.127 | 21.44 0.127 | 49.99 0.787 | 70.64 1.57 | 16.00 0.381 | 28.96 0.381 | 15.49 0.381 | 2.24 0.254 | 6.60 0.254 | 4.98 0.254 | 3.18 0.127 | 2.72 0.381 | 2.16 0.127 | 11.13 1.57 |
| RH100 NH100 | 57.15 0.254 | 25.12 0.787 | 71.42 0.787 | 88.90 0.787 | 28.58 0.787 | 4.78 0.254 | 25.12 0.787 | 2.36 0.254 | 7.92 0.787 | 4.78 0.254 | 3.18 0.127 | 7.92 0.787 | 2.16 0.127 | 76.20 0.787 |
| RH250 NH250 | 57.15 0.254 | 25.12 0.787 | 71.42 0.787 | 88.90 0.787 | 28.58 0.787 | 4.78 0.254 | 25.12 0.787 | 2.36 0.254 | 7.92 0.787 | 4.78 0.254 | 3.18 0.127 | 7.92 0.787 | 2.16 0.127 | 76.20 0.787 |
Power Rating and Derating
Vishay RH resistor wattage ratings are based on mounting to specified heat sinks. Derating is required for ambient temperatures above 25 C and when the recommended heat sink area is reduced. Free air power ratings are also provided.
| Global Model | Free Air Power Rating (W at 25 C) |
| RH005 NH005 | 4.5 / 7.5 |
| RH010 NH010 | 12.5 |
| RH025 NH025 | 20 |
| RH050 NH050 | 40 |
| RH100 NH100 | 100 |
| RH250 NH250 | 100 |
Get in Touch