Product Overview

The VQ21 is an improved poison-resistant sensor designed for the detection of combustible gases, particularly methane in air mixtures, from 0.1% concentration upwards. It offers no interference from water vapour or carbon dioxide and is suitable for atmospheres where traces of silicone and other poisoning agents may be present. When used with the recommended bridge circuit and mounting arrangement, it provides a minimum sensitivity of 10 mV/% methane. The sensor consists of two matched elements: a detector (red sleeve) and a compensator (black sleeve).

Product Attributes

  • Brand: SGX Sensortech(IS) Ltd
  • Product Type: Combustible Gas Detector Elements
  • Model: VQ21
  • Element Identification: Serial number on can (red for detector, black for compensator)
  • Detector Label: Red circular label on base
  • Origin: Registered in England No.08067077
  • Issue: A1A-VQ21 Issue 4, March 2007

Technical Specifications

Specification Value Notes
Operation Continuous 1
Bridge Supply 2.0 + 0.1 V
Bridge Power Consumption 0.75 W max
Typical Average Sensor Current 300 mA
Minimum Sensitivity 10 mV/% methane 2
Linearity Linear up to 5% methane
Response Time (1 1/4% in 2 1/2% concentration) 2 seconds 2, 3
Maximum Methane Concentration 5 % 4
Trimming Resistor (R) Supplied where necessary, connected across compensator element 5

Outline Dimensions (2310C)

Ref Millimetres
A 11.05 + 0.25
B 6.10 + 0.25
C 3.56 + 0.13
D 63.50 min
E 1.02
F 7.37 + 0.51
G 8.20 max
H 9.53
J 1.52

Recommended Mounting Arrangements

Ref Millimetres
AA 19.05 max
AB 9.53 + 0.13
AC 8.33 + 0.13
AD 8.20 min
AE 19.05 max
AF 9.53 + 0.13
AG 8.20 min

Notes

  1. Operation may be under either direct flow or diffusion conditions in appropriate mountings.
  2. With open-circuit conditions at the bridge output.
  3. The response time is a function of the type of mounting used.
  4. If the VQ21 is exposed to greater than 5% methane concentration, the calibration of the instrument should be checked.
  5. The elements are supplied as a matched pair with a trimming resistor R of the correct value which is supplied where necessary. The trimming resistor is to be connected across the compensator element.
  6. The resistance to poisoning by silicone compounds is partly dependent upon the type of housing within which the elements are mounted.
  7. The response to certain of the heavy flammable vapours, especially aromatic substances with side chains, may be lower than that calculated from the conversion (K) factors listed in the preamble.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Changsha Purple Horn E-Commerce Co., Ltd.
Location 2332 Kaibin Commercial Plaza, No. 419 Shaoshan Middle Road, Shazitang Street, Yuhua District, Changsha City, Hunan Province
Contact Person Coral

Request A Quote

Please check your email address.
Your message must be at least 20 characters.