High Sensitivity Gas Sensor Amphenol PS4-CO-100 Electrochemical Sensor for Industrial Safety Systems

Price Negotiable
Price: Negotiable
MOQ: Negotiable
Delivery Time: Negotiable
Product Description

Product Overview

The SGX series of PS1 and PS4 Electrochemical gas sensors utilize a revolutionary 'Solid Polymer Electrolyte' technology based on catalytic reaction. These sensors generate a small current proportional to the target gas concentration, offering a stable, high-quality, and cost-effective manufacturing process. Available in a very small size, they are highly sensitive, do not require power, and exhibit very low cross-sensitivity to other gases. Key applications include TLV monitoring, environmental air monitoring, parking garages, steel industry, oil & petrochemical industry, and leakage detection.

Product Attributes

  • Brand: SGX
  • Technology: Solid Polymer Electrolyte
  • Operating Principle: Amperometric, 3-electrode
  • Housing Material: PPO
  • Origin: Poland (SGX Europe Sp. z o.o.)

Technical Specifications

Specification PS1-CO-100 PS4-CO-100
Sensitivity 25 10 nA / ppm 25 10 nA / ppm
Measurement Range 0 100 ppm 0 100 ppm
Zero Current 100 nA 100 nA
Maximum Overload 1000 ppm 1000 ppm
Response Time (T50) < 10s < 10s
Response Time (T90) < 30s < 30s
Repeatability < 1% < 1%
Lower Detectable Limit (LDL) 2 ppm 2 ppm
Linear Range 100 ppm 100 ppm
Resolution (16Bit ADC) <0.1ppm <0.1ppm
Operating Humidity Range 15-95% RH
Pressure Range 800 to 1200 hPa
Storage Temperature 0 to 20
Temperature Range -40C to +55C
Recommended Load Resistor 100
Bias Voltage 0 mV
Warm Up Time < 60 s
Long-Term Drift < 1 %/month
Zero Drift in Clean Air < 2 ppm
Storage Life 12 months
Expected Lifetime > 5 years in air
Warranty 12 months
Weight < 0.7g < 6g

Features

  • Small size
  • Fast response time
  • Wide temperature range
  • Extreme linear response up to high concentration
  • No electrolyte leakage
  • High sensitivity
  • Excellent sensitivity at low temperatures
  • Stable zero point

Important Notes

  • All performance is based on conditions at 20C, 50% RH and 1 atm, flow rate>150qcm/min, using SGX recommended circuitry.
  • Sensor performance is temperature dependant; please contact SGX for temperature performance other than 20C.
  • Do not solder to the connector pins as this may damage the sensor and thereby invalidate the warranty.
  • Details on recommended connector pins can be found in the Frequently Asked Questions within the Gas Sensor section of the SGX website.
  • Exposure to high concentrations of solvent vapours should be avoided during storage, fitting into instruments, and operation.
  • When using sensors on printed circuit boards (PCBs), degreasing agents should be used prior to the sensor being fitted.
  • For life safety performance requirements, it is recommended that all sensors and instruments using these sensors are checked for response to gas before use.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Changsha Purple Horn E-Commerce Co., Ltd.
Location 2332 Kaibin Commercial Plaza, No. 419 Shaoshan Middle Road, Shazitang Street, Yuhua District, Changsha City, Hunan Province
Contact Person Coral

Request A Quote

Please check your email address.
Your message must be at least 20 characters.