industrial vibration sensor Amphenol PCC420AR-10-R6 with loop powered 4-20 mA output and hermetic sealing
Product Overview
The Wilcoxon Sensing Technologies PCC420A series are loop-powered sensors designed to provide a 4-20 mA output proportional to vibration, enabling continuous trending of overall machine vibration. This data assists in alerting users to changing machine conditions and prioritizing maintenance needs. The sensors offer a choice between True RMS or calculated peak acceleration output, allowing for selection based on specific requirements. Their compact housing is suitable for applications with height restrictions, and they can be easily integrated into existing process control systems. Manufactured in an approved ISO 9001 facility, these sensors are designed for reliability and performance in industrial environments.
Product Attributes
- Brand: Wilcoxon Sensing Technologies
- Company: An Amphenol Company
- Origin: Manufactured in an approved ISO 9001 facility
- Certifications: ISO 9001
- Sealing: Hermetic
- Case Material: 316L stainless steel
Technical Specifications
| Specification | Details | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Model Series | PCC420A | ||||||||||||||||||
| Output Type | 4-20 mA loop powered | ||||||||||||||||||
| Output Signal Options | True RMS acceleration (R) or Calculated Peak acceleration (P) | ||||||||||||||||||
| Full Scale Options (g / m/sec) | 05 (49), 10 (98), 20 (196), 50 (490) | ||||||||||||||||||
| Connector Options | 2-pin MIL-C-5015 (R6) or 4-pin M12 | ||||||||||||||||||
| Frequency Response | 10% from 10 Hz - 1.0 kHz; 3 dB from 1.0 Hz - 2.0 kHz | ||||||||||||||||||
| Repeatability | 2% | ||||||||||||||||||
| Transverse Sensitivity (max) | 5% | ||||||||||||||||||
| Power Requirements | 2-wire loop power: 12 - 30 VDC at sensor terminals | ||||||||||||||||||
| Loop Resistance (max at 24 VDC) | 700 | ||||||||||||||||||
| Turn on Time (4-20 mA loop) | |||||||||||||||||||
| Grounding | Case isolated, internally shielded | ||||||||||||||||||
| Operating Temperature Range | 40 to +105 C | ||||||||||||||||||
| Vibration Limit | 250 g peak | ||||||||||||||||||
| Shock Limit | 2,500 g peak | ||||||||||||||||||
| Sensing Element Design | PZT, shear | ||||||||||||||||||
| Weight | 120 grams | ||||||||||||||||||
| Mounting | 1/4-28 UNF tapped hole | ||||||||||||||||||
| Accessories Supplied | SF6 mounting stud; calibration data (level 2) | ||||||||||||||||||
| Connections (-R6 models) | Pin A: loop positive (+), Pin B: loop negative (-), Ground shell | ||||||||||||||||||
| Connections (-M12 models) | Pin 1: loop positive (+), Pin 2: loop negative (-), Pin 3: N/C, Pin 4: N/C, Ground shell | ||||||||||||||||||
| Maximum Loop Resistance Calculation | RL = (VDC power 10 V) / 0.02 A | ||||||||||||||||||
| Minimum RL Wattage Capability Calculation | (0.0004 x RL) | ||||||||||||||||||
| Loop Resistance & Wattage Table |
|
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.