Product Description

Product Overview

The Telaire 8000 Ventostat series offers wall-mount CO2, humidity, and temperature transmitters designed for controlled ventilation in commercial HVAC applications. These devices help maintain indoor air quality, prevent energy waste from over-ventilation, and are ideal for areas with fluctuating occupancy. Featuring a patented Absorption Infrared Gas sensing engine and ABC Logic self-calibration system, they provide high accuracy and eliminate the need for manual calibration in most applications, backed by a lifetime CO2 calibration guarantee for T8100 and T8300 models. The two-piece design allows for easy replacement without rewiring, and modern enclosures with customizable branding are available. Suitable for controlling specific areas like conference rooms, classrooms, and meeting halls.

Product Attributes

  • Brand: Telaire (Amphenol Advanced Sensors)
  • Series: Ventostat 8000
  • Sensing Technology: Patented Absorption Infrared Gas sensing engine
  • Self-Calibration: Patented ABC Logic
  • Calibration Guarantee: Lifetime for T8100/T8300 (single channel), 2-year for T8200 (dual channel)
  • Enclosure: Modern design, customizable branding available. Smaller enclosure versions available (81.4 mm x 86.4 mm).
  • Certifications: CE and RoHS compliant
  • Design: Two-piece design for easy replacement
  • Filter: Gas permeable, water resistant CO2 diffusion filter
  • Output Options: Dual simultaneous analog (V & mA), BACnet (MS/TP, RS485)
  • Origin: Controlled Ventilation

Technical Specifications

Specification Details
Models T8100 (Single Channel, ABC Logic), T8200 (Dual Channel), T8300 (Single Channel with Pitot Tube Kit)
CO2 Measurement Range 0 to 2000 ppm (Standard)
0 to 5000 ppm (T8100/T8200/T8300 -5P models)
0 to 10,000 ppm (T8200 - 10P models)
0 to 20,000 ppm (T8200 - 20P models)
CO2 Accuracy 30ppm or 3% of reading, whichever is higher (excludes calibration gas and DA error)
Power Supply Requirements 18-30 VAC RMS, 50/60 Hz, or 10.8 to 42 VDC, polarity protected
Power Consumption Typical 0.7 W at 24V AC RMS
Temperature Dependence 0.2% FS per C (0.11% per F)
Stability T8100/T8300: <2% of FS over life (15 years)
T8200: <5% of FS or <10% reading annual over life (10 years)
Pressure Dependence 0.135% of reading per mm Hg
Warranty 24 months on mechanical defects
Signal Update Every 5 seconds
CO2 Warm-up Time < 2 minutes (operational), 10 minutes (maximum accuracy)
Operating Conditions 32F to 122F (0C to 50C), 0 to 95% RH (non-condensing)
Storage Conditions -40F to 158F (-40C to 70C)
Flammability Classification UL94 5VA
Thermistor Type NTC 10 K W (Passive, not BACnet version)
Thermistor Accuracy 1C (15 to 35C)
RH Sensing Element Capacitive polymer sensor
RH Range 0% to 99% RH (non-condensing)
RH Accuracy (25C) 2.5% RH (20 to 80% RH), 3.5% RH (80% RH)
Active Temperature Accuracy 0.8C @ 22C
Active Temperature Range 32F to 122F (0 to 50C)
Analog Output 0 to 10 V (100 W impedance) and 4 to 20mA (RL max 500 W) simultaneously
BACnet Version MS/TP, RS485, Baud rates 38400 or 9600
T8300 Pitot Tube Kit For duct measurement of CO2
Field Replaceable RH Sensor Tip Maintains 2.5% RH accuracy
Accessories T1505 Splash Resistant Enclosure, T1552 Outside Air Enclosure, T1508 Aspiration Box for Duct Mounting
UIP Software (T2090) Altitude adjustment, analog output adjustment, calibration, ABC Logic control, temperature unit change, graphing/logging

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Changsha Purple Horn E-Commerce Co., Ltd.
Location 2332 Kaibin Commercial Plaza, No. 419 Shaoshan Middle Road, Shazitang Street, Yuhua District, Changsha City, Hunan Province
Contact Person Coral

Request A Quote

Please check your email address.
Your message must be at least 20 characters.