Hollow shaft angle measurement sensor Amphenol PST360G2-1A-C0026-ERA040-05K with digital SPI interface

Price Negotiable
Price: Negotiable
MOQ: Negotiable
Delivery Time: Negotiable
Product Description

Product Overview

The PST-360 is a sensor featuring a digital Serial Peripheral Interface (SPI) protocol. It operates as a slave node, providing angle measurement data. The device is designed for applications requiring precise angular positioning and communicates via a three-wire protocol (/SS, SCLK, MOSI-MISO). It offers a 360 ERA (Electronic Resolution Angle) and supports a simple SPI protocol.

Product Attributes

  • Brand: Piher Sensors & Controls SA
  • Company Affiliation: AmphenolTM company
  • Origin: Spain
  • Protocol: SPI Protocol (Simple)
  • Output Function: Curve 0000
  • Angle Measurement: 360 ERA
  • Rotor Type: Hollow Shaft

Technical Specifications

Specification Value Details
Model PST-360
Ordering Code Example PST360G2-1S-C0000-ERA360-05K
Rotor 14mm
Supply Voltage (Vdd) 5V 10%
Temperature Range -40 C to +125 C
Signal Output Type Digital SPI Protocol
Connections Brown: Vdd
Blue: Ground
Black: MOSI /SS
White: SCLK
Grey: MISO
Recommended connections for power supply at the end.
SPI Protocol - /SS Pin 5V tolerant digital input
SPI Protocol - SCLK Pin 5V tolerant digital input
SPI Protocol - MOSI/MISO Pin 5V tolerant open drain digital input/output
SPI Protocol - Slow Mode Timing (Oscillator 7MHz) t1: 6.9 s (Min)
t2: 37.5 s (Min)
t4: 6.9 s (Min)
t5: 1500 s (Min)
t6: 6.9 s (Min)
t7: 45 s (Min)
t9: TStartUp:
t5: Minimum time between reset-inactive and any master signal change.
t7: Minimum time between StartByte and Byte0.
TStartUp: Slave start-up time after power-up or internal failure.
SPI Protocol - Data Frame Structure 10 bytes total 2 start bytes (AAh, FFh), 2 data bytes (DATA16), 2 inverted data bytes (/DATA16), 4 all-Hi bytes.
SPI Protocol - Frame Transmission Asynchronous No inter-frame time defined.
SPI Protocol - Slave Reset Master deactivates /SS high for at least t5 (1.5 ms) to synchronize. Slave resets after 1 second or after an error frame on internal soft failures.
SPI Protocol - Slave Start-Up 16 ms Serial protocol link enabled after first synchronization. /SS and SCLK ignored during start-up.
SPI Protocol - Error Handling MOSI/MISO pin remains Hi-impedant for ROM CRC, EEPROM CRC, RAM check, intelligent watchdog errors. For other errors, serial protocol is initialized and error condition is readable. Slave performs soft reset after sending error frame.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Changsha Purple Horn E-Commerce Co., Ltd.
Location 2332 Kaibin Commercial Plaza, No. 419 Shaoshan Middle Road, Shazitang Street, Yuhua District, Changsha City, Hunan Province
Contact Person Coral

Request A Quote

Please check your email address.
Your message must be at least 20 characters.