Closed loop Hall effect sensor LEM LA25 NP with wide frequency bandwidth and current overload capability

Price Negotiable
Price: Negotiable
MOQ: Negotiable
Delivery Time: Negotiable
Product Description

Product Overview

The LEM LA 25-NP is a closed-loop Hall effect current transducer designed for precise electronic measurement of DC, AC, and pulsed currents with galvanic isolation between primary and secondary circuits. It offers excellent accuracy, very good linearity, low temperature drift, optimized response time, and a wide frequency bandwidth, making it suitable for various industrial applications including AC and DC motor drives, UPS, SMPS, and welding power supplies. The transducer features an isolated plastic case recognized according to UL 94-V0 and provides high immunity to external interference and current overload capability.

Product Attributes

  • Brand: LEM
  • Origin: Not specified
  • Material: Isolated plastic case (UL 94-V0 recognized)
  • Color: Not specified
  • Certifications: UL 94-V0, EN 50178, IEC 61010-1

Technical Specifications

ParameterValueUnitNotes
Electrical Data
Primary nominal current rms (IPN)25A
Primary current, measuring range (IPM)0 .. 36A
Secondary nominal current rms (ISN)25mA
Conversion ratio (KN)1-2-3-4-5 : 1000
Supply voltage (VC) ( 5 %) 15V
Current consumption (IC)10 + ISmA
Accuracy - Dynamic performance data
Accuracy @ IPN, TA = 25C 0.5 %Max
Linearity error (L)% Typ
Offset current (IO) @ IP = 0, TA = 25C 0.05 / 0.15mATyp / Max
Magnetic offset current (IOM) @ IP = 0 and specified RM, after overload 0.05 / 0.15mATyp / Max
Temperature variation of IO (0C .. + 25C) 0.06 / 0.25mATyp / Max
Temperature variation of IO (+ 25C .. + 70C) 0.10 / 0.35mATyp / Max
Temperature variation of IO (- 25C .. + 85C) 0.5mAMax
Temperature variation of IO (- 40C .. + 85C) 1.2mAMax
Response time (tr) to 90 % of IPN steps
di/dt accurately followed> 50A/s
Frequency bandwidth (- 1 dB) (BW)DC .. 150kHz
General Data
Ambient operating temperature (TA)- 40 .. + 85C
Ambient storage temperature (TS)- 45 .. + 90C
Primary coil resistance per turn (RP) @ TA = 25Cm
Secondary coil resistance (RS) @ TA = 70C110
Secondary coil resistance (RS) @ TA = 85C115
Isolation resistance (RIS) @ 500 V, TA = 25C> 1500M
Mass22g
Isolation Characteristics
Rms voltage for AC insulation test (Vd), 50 Hz, 1 min2.5kV
Impulse withstand voltage (Vw) 1.2/50 s9kV
Creepage distance (dCp)10.63mm
Clearance (dCI)10.63mm
Comparative Tracking Index (CTI) (group IIIa)175
Dimensions (mm)
Primary turnsIPN [A]IP [A]ISN [mA]KNRP [m]LP [H]Connections
12536251 / 10000.30.023IN(1-5), OUT(6-10)
21218242 / 10001.10.09IN(1-5), OUT(6-10)
3812243 / 10002.50.21IN(1-5), OUT(6-10)
469244 / 10004.40.37IN(1-5), OUT(6-10)
557255 / 10006.30.58IN(1-5), OUT(6-10)

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Changsha Purple Horn E-Commerce Co., Ltd.
Location 2332 Kaibin Commercial Plaza, No. 419 Shaoshan Middle Road, Shazitang Street, Yuhua District, Changsha City, Hunan Province
Contact Person Coral

Request A Quote

Please check your email address.
Your message must be at least 20 characters.