Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
                                                                                                           
Verified Supplier
8 Years
Since 2018
Menu

Industrial 2 Wire HART Pressure Measurement Transmitter PR 5337A With 4-20MA Output

Price Negotiable
Price: 99USD
MOQ: 1
Delivery Time: 5-7 work days
Brand: PR
Product Description
2-wire Transmitter with HART Protocol
PR 5337A
Product Overview
  • RTD, TC, Ohm, and bipolar mV input capability
  • 2 analog inputs with 5 device variables and status monitoring
  • Selectable HART protocol revision (HART 5 or HART 7)
Environmental Conditions
Operating temperature-40°C to +85°C
Calibration temperature20...28°C
Relative humidity< 95% RH (non-condensing)
Protection degree (enclosure/terminal)IP68 / IP00
Mechanical Specifications
DimensionsØ 44 x 20.2 mm
Weight approx.50 g
Wire size1 x 1.5 mm² stranded wire
Screw terminal torque0.4 Nm
VibrationIEC 60068-2-6
2...25 Hz±1.6 mm
25...100 Hz±4 g
Common Specifications
Supply
Supply voltage8.0...35 VDC
Isolation Voltage
Isolation voltage, test / working1.5 kVAC / 50 VAC
Response Time
Response time (programmable)1...60 s
Voltage drop8.0 VDC
Signal / noise ratio> 60 dB
ProgrammingHART & PR 5909 Loop Link communications interface
AccuracyBetter than 0.05% of selected range
Signal dynamics, input22 bit
Signal dynamics, output16 bit
EMC immunity influence< ±0.1% of span
Extended EMC immunity: NAMUR NE21, A criterion, burst< ±1% of span
Input Specifications
Common Input Specifications
Max. offset50% of selected max. value
RTD Input
RTD typePt50/100/200/500/1000; Ni50/100/120/1000
Cable resistance per wire5 Ω (up to 50 Ω per wire possible with reduced accuracy)
Sensor currentNom. 0.2 mA
TC Input
Thermocouple typeB, E, J, K, L, N, R, S, T, U, W3, W5, LR
Cold junction compensation (CJC)Constant, internal or external via Pt100 or Ni100 sensor
Voltage Input
Measurement range-800...+800 mV
Min. measurement range (span)2.5 mV
Input resistance10 MΩ
Output Specifications
Current Output
Signal range4…20 mA
Min. signal range16 mA
Load (@ current output)≤ (Vsupply - 8) / 0.023 [Ω]
Sensor error indicationProgrammable 3.5…23 mA
NAMUR NE43 Upscale/Downscale23 mA / 3.5 mA
Common Output Specifications
Updating time440 ms
HART protocol revisionsHART 7 and HART 5
Intrinsic Safety / Ex Marking
ATEXII 3 G Ex nA [ic] IIC T6...T4 Gc, II 3 G Ex ec [ic] IIC T6...T4 Gc, II 3 G Ex ic IIC T6...T4 Gc, II 3 D Ex ic IIIC Dc
IECExEx nA [ic] IIC T6…T4 Gc, Ex ec [ic] IIC T6…T4 Gc, Ex ic IIC T6…T4 Gc, Ex ic IIIC Dc
CSACl. I, Div. 2, Gp. A, B, C, D T6...T4, Ex nA[ic] IIC T6…T4 Gc
INMETROEx ec [ic] IIC T6...T4 Gc, Ex ic IIC T6...T4 Gc, Ex ic IIIC Dc
Compliance with Authority Requirements
EMC2014/30/EU
ATEX2014/34/EU
RoHS2011/65/EU
EACTR-CU 020/2011
EAC ExTR-CU 012/2011
Approvals
ATEXDEKRA 20ATEX0109X
IECExDEK 20.0063X
CSA1125003
INMETRODEKRA 23.0011X
EAC ExEAEU KZ 7500361.01.01.08756
DNV MarineTAA0000101
SILHardware assessed for use in SIL applications
Similar Products

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Shaanxi Qindiyuan Environmental Protection Equipment Co., Ltd.
Location F1-803, Guorun Silu Jin Rong Zhongxin, Qindu District, Xianyang City, Shaanxi Province
Contact Person Leon

Request A Quote

Please check your email address.
Your message must be at least 20 characters.