2-Wire HART Transmitter PR 6337A
1- or 2-channel converter for RTD, TC, Ohm, and bipolar mV signals with 2 analogue inputs and 5 device variables with status available. HART protocol revision selectable.
Environmental Conditions
Operating temperature -40°C to +85°C
Storage temperature -40°C to +85°C
Calibration temperature 20...28°C
Relative humidity < 95% RH (non-condensing)
Protection degree IP20
Mechanical Specifications
Dimensions (HxWxD) 109 x 23.5 x 104 mm
Weight (1 / 2 channels) 150 / 200 g
DIN rail type DIN EN 60715/35 mm
Wire size 0.13...2.08 mm² AWG 26...14 stranded wire
Screw terminal torque 0.5 Nm
Common Specifications
Supply
Supply voltage 8.0...35 VDC
Internal power dissipation, 1 / 2 ch. 19 mW...0.8 / 1.6 W
Isolation Voltage
Isolation voltage, test / working 1.5 kVAC / 50 VAC
Response Time & Performance
Response time (programmable) 1...60 s
Voltage drop 8.0 VDC
Signal dynamics, input 22 bit
Signal dynamics, output 16 bit
Signal / noise ratio > 60 dB
Accuracy Better than 0.05% of selected range
EMC immunity influence < ±0.1% of span
Extended EMC immunity: NAMUR NE21, A criterion, burst < ±1% of span
Input Specifications
Common Input Specifications
Max. offset 50% of selected max. value
RTD Input
RTD type Pt50/100/200/500/1000; Ni50/100/120/1000
Cable resistance per wire 5 Ω (up to 50 Ω per wire is possible with reduced measurement accuracy)
Sensor current Nom. 0.2 mA
Linear Resistance Input
Linear resistance min....max. 0 Ω...7000 Ω
TC Input
Thermocouple type B, E, J, K, L, N, R, S, T, U, W3, W5
Cold junction compensation (CJC) Constant, internal or external via a Pt100 or Ni100 sensor
Voltage Input
Measurement range -800...+800 mV
Min. measurement range (span) 2.5 mV
Input resistance 10 MΩ
Output Specifications
Current Output
Signal range 4…20 mA
Min. signal range 16 mA
Load (@ current output) ≤ (Vsupply - 8) / 0.023 [Ω]
Sensor error indication Programmable 3.5…23 mA
NAMUR NE43 Upscale/Downscale 23 mA / 3.5 mA
Common Output Specifications
Updating time 440 ms
HART protocol revisions HART 7 and HART 5
Compliance & Standards
EMC 2014/30/EU & UK SI 2016/1091
ATEX 2014/34/EU & UK SI 2016/1107
RoHS 2011/65/EU & UK SI 2012/3032
EAC TR-CU 020/2011
EAC Ex TR-CU 012/2011
Approvals & Certifications
ATEX DEKRA 20ATEX0109X
IECEx DEK 20.0063X
CSA 1125003
INMETRO DEKRA 23.0011X
EAC Ex EAEU KZ 7500361.01.01.08756
SIL Hardware assessed for use in SIL applications
Similar Products

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.