PROFIBUS PA Profile 4.0 Temperature Transmitters PR 5450D With RTD / TC / Potentiometer Inputs
Price:
435
MOQ:
1
Delivery Time:
5-7 work days
Brand:
PR
Product Description
PROFIBUS PA Temperature Transmitter PR 5450D
Product Overview
PROFIBUS PA Profile 4.0 compatible temperature transmitter supporting RTD, TC, potentiometer, linear resistance and bipolar mV inputs. Features single or true dual inputs with sensor redundancy and drift detection capabilities.
Environmental Conditions
| Operating temperature | -40°C to +80°C |
| Storage temperature | -50°C to +85°C |
| Calibration temperature | 23...25°C |
| Relative humidity | < 99% RH (non-condensing) |
| Protection degree (enclosure/terminal) | IP68 / IP00 |
Mechanical Specifications
| Dimensions | Ø 44 x 21.45 mm |
| Center hole diameter | Ø 6.35 mm / ¼ in |
| Weight approx. | 50 g |
| Wire size | 1 x 1.5 mm² stranded wire |
| Stripping length | 7 mm |
| Screw terminal torque | 0.4 Nm |
| Vibration | IEC 60068-2-6 2...25 Hz: ±1.6 mm 25...100 Hz: ±4 g |
Common Specifications
Supply
| Supply voltage | 9.0...30 VDC |
| Supply voltage in FISCO installations | 9.0...17.5 VDC |
| Internal power dissipation | < 352 mW |
Isolation Voltage
| Isolation voltage, test / working | 2.5 kVAC / 42 VAC |
Performance Characteristics
| Response time | < 400 ms |
| Programmable damping | 0...60 s |
| Write protection | Jumper |
| Warm-up time | < 5 min. |
| Start-up time | < 15 s |
| Programming | PROFIBUS GSD, DD |
| Signal / noise ratio | > 60 dB |
| Long-term stability, first year / 5 years | ± 0.05% of reading / ± 0.10% of reading |
| Updating time, PROFIBUS | < 100 ms |
| Signal dynamics, input | 24 bit |
| Accuracy | See manual for details |
| EMC immunity influence | < ±0.1% of span |
| Extended EMC immunity: NAMUR NE21, A criterion, burst | < ±1% |
Input Specifications
RTD Input
| RTD type | Pt10...10000, Ni10...10000, Cu5...1000 |
| Permissible cable resistance per wire | ≤ 50 Ω |
| Effect of sensor cable resistance (3-/4-wire) | < 0.002 Ω / Ω |
| Sensor current | < 0.15 mA |
| Sensor error detection | None, Shorted, Broken, Shorted or Broken |
TC Input
| Thermocouple type | B, E, J, K, L, N, R, S, T, U, W3, W5, LR |
| Cold junction compensation (CJC) | Constant, internal or external via a Pt100 or Ni100 sensor |
| Sensor error detection | None, Shorted, Broken, Shorted or Broken |
Linear Resistance Input
| Measurement range / min. range (span) | 0 Ω...100 kΩ / 25 Ω |
| Permissible cable resistance per wire | ≤ 50 Ω |
| Sensor current | < 0.15 mA |
| Sensor error detection | None, Broken |
Potentiometer Input
| Potentiometer min....max. | 10 Ω...100 kΩ |
| Measurement range / min. range (span) | 0...100% / 10% |
| Permissible cable resistance per wire | ≤ 50 Ω |
| Sensor current | < 0.15 mA |
| Sensor error detection | None, Shorted, Broken, Shorted or Broken |
mV Input
| Measurement range | -800...+800 mV (bipolar) -100...1700 mV |
| Min. measurement range (span) | 2.5 mV |
| Input resistance | 10 MΩ |
| Sensor error detection | None, Broken |
Output Specifications
PROFIBUS PA Connection
| PROFIBUS PA protocol | Profile A&B, ver. 4.0 (compatible with 3.02) |
| PROFIBUS PA protocol standard | EN 50170 vol. 2 |
| PROFIBUS PA address (at delivery) | 126 |
| PROFIBUS PA physical layer | 2 x function blocks, 1 / 2 transducer block(s) |
| PROFIBUS PA termination | 100 Ω +1 μF |
Compliance & Approvals
Observed Authority Requirements
| EMC | 2014/30/EU |
| ATEX | 2014/34/EU |
| RoHS | 2011/65/EU |
| EAC | TR-CU 020/2011 |
| EAC Ex | TR-CU 012/2011 |
Certifications & Approvals
| ATEX | DEKRA 24ATEX0006X |
| IECEx | IECEx DEK. 24.0005X |
| CSA | CSA25CA80210307 |
| c FM us | FM25US0051X / FM25CA0022X |
| INMETRO | DEKRA 25.0004X |
| NEPSI | Pending |
| EAC Ex | EAEU KZ 7500361.01.01.10203 |