20Hz Ex Solenoid / Alarm Driver PR 5203B-U9 1 / 2 Channel UL 913 Approved
Price:
150-300usd
MOQ:
1
Delivery Time:
5-7 work days
Brand:
PR
Product Description
Ex Solenoid / Alarm Driver PR 5203B-U9
UL 913-approved version for US market only. Features 1- or 2-channel configuration as solenoid driver for intrinsically safe areas with 3.75 kVAC galvanic isolation and digital control.
Product Overview
- 1- or 2-channel solenoid driver for intrinsically safe areas
- 3.75 kVAC galvanic isolation (3-/5-port configuration)
- Digitally controlled operation
- UL 913-approved for US market
- Maximum frequency: 20 Hz
Environmental Specifications
| Operating temperature | -20°C to +60°C |
| Calibration temperature | 20...28°C |
| Relative humidity | < 95% RH (non-condensing) |
| Protection degree | IP20 |
Mechanical Specifications
| Dimensions (HxWxD) | 109 x 23.5 x 130 mm |
| Weight approx. | 230 g |
| DIN rail type | DIN EN 60715/35 mm |
| Wire size | 0.13...2.08 mm² AWG 26...14 stranded wire |
| Screw terminal torque | 0.5 Nm |
Electrical Specifications
Power Supply
| Supply voltage, universal | 21.6...253 VAC, 50...60 Hz or 19.2...300 VDC |
| Fuse | 400 mA SB / 250 VAC |
| Max. required power | ≤ 4 W (2 channels) |
| Internal power dissipation | ≤ 2 W (2 channels) |
Isolation Voltage
| Isolation voltage, test / working | 3.75 kVAC / 250 VAC |
| PELV/SELV | IEC 61140 |
Input Specifications
NPN and Mechanical Switch
| Trigger level LOW | ≤ 4.0 VDC |
| Trigger level HIGH | ≥ 7.0 VDC |
| Max. external voltage | 28 VDC |
| Input impedance | 3.48 kΩ |
PNP
| Trigger level LOW | ≤ 4.0 VDC |
| Trigger level HIGH | ≥ 7.0 VDC |
| Max. external voltage | 28 VDC |
| Input impedance | 3.48 kΩ |
Output Specifications
| Output voltage | See I.S. data in manual |
| Output current | See I.S. data in manual |
| Output ripple | < 40 mVRMS |
Compliance & Approvals
Authority Requirements
| EMC | 2014/30/EU |
| LVD | 2014/35/EU |
Certifications
| c UL us, UL 508 | 05122003-E233311 |
| c UL us, UL 913 | 05122003-E233311 |
Programming: DIP switches
EMC immunity influence: < ±0.5% of span
Extended EMC immunity: NAMUR NE21, A criterion, burst < ±1% of span
EMC immunity influence: < ±0.5% of span
Extended EMC immunity: NAMUR NE21, A criterion, burst < ±1% of span