Aluminum Conductor ABC Cable XLPE Insulated 600V Overhead Aerial Cable

Price Negotiable
Price: 0.1-5
MOQ: 100
Delivery Time: 10 Days
Brand: Minfeng
Product Description
Aluminum Conductor ABC Cable PE or XLPE or PVC Insulated Overhead Aerial Line
Aluminum Conductor PVC Insulated ABC Cable
Applications

Covered line wire is used primarily for 600V overhead secondary distribution lines. It is not an electrically insulated conductor and is treated as bare conductor when installed.

Construction

The conductors are 1350-H19 Aluminum Wire, 6201-T81 Aluminum Alloy or ACSR conductors, concentrically stranded and covered for weather proofing with polyethylene, high density polyethylene (HDPE) or cross-linked polyethylene (XLPE).

Duplex Service Drop - Aluminum Conductor
Applications

Primarily used for 120 volt overhead service applications such as street lighting, outdoor lighting, and temporary service for construction. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.

Construction

Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or cross-linked polyethylene (XLPE). Neutral messengers are concentrically stranded 6201, AAC, or ACSR.

Triplex Service Drop - Aluminum Conductor
Applications

Used to supply power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.

Construction

Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or cross-linked polyethylene (XLPE). Neutral messengers are concentrically stranded 6201, AAC, or ACSR.

Quadruplex Service Drop - Aluminum Conductor
Applications

Used to supply 3-phase power, usually from a pole-mounted transformer, to the user's service head where connection to the service entrance cable is made. To be used at voltages of 600 volts phase-to-phase or less and at conductor temperatures not to exceed 75°C for polyethylene insulated conductors or 90°C for cross-linked polyethylene (XLPE) insulated conductors.

Construction

Conductors are concentrically stranded, compressed 1350-H19 aluminum. Insulated with either polyethylene or cross-linked polyethylene (XLPE). Neutral messengers are concentrically stranded 6201, AAC, or ACSR. Conductors are manufactured with ridges for phase identification (one conductor one ridge, one conductor two ridges, one conductor plain).

Standards
  • ASTM B-230 - Aluminum Wire 1350-H19 for Electrical Purposes
  • ASTM B-231 - Concentric-Lay-Stranded Aluminum Conductors
  • ASTM B-232 - Concentric-Lay-Stranded Aluminum Conductors, Coated-Steel Reinforced (ACSR)
  • ASTM B-399 - Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors
  • ICEA S-61-402 - Thermoplastic-insulated Wire And Cable For The Transmission And Distribution Of Electrical Energy
  • ICEA S-66-524 - XLPE Insulated Wire and Cable For the Transmission and Distribution of Electrical Energy
ABC Aerial Cable with ACSR Messenger Core Specifications
Nominal Section Area (sqmm) Conductor Structure Insulation Material Insulation Thick Approx. Overall
Phase | Neutral Phase (Compacted AL) | Neutral (Bare ACSR)
1x16+16 7/1.72 | 6/1.72 | 1/1.72 XLPE 1.2 12.5
1x25+25 7/2.15 | 6/2.15 | 1/2.15 XLPE 1.2 14.9
1x35+35 7/2.54 | 6/2.54 | 1/2.54 XLPE 1.4 17.5
1x70+70 19/2.15 | 12/2.15 | 7/2.15 XLPE 1.4 23.6
1x95+95 19/2.54 | 12/2.54 | 7/2.54 XLPE 1.6 27.6
2x16+16 7/1.72 | 6/1.72 | 1/1.72 XLPE 1.2 14.2
2x25+25 7/2.15 | 6/2.15 | 1/2.15 XLPE 1.2 16.7
2x35+35 7/2.54 | 6/2.54 | 1/2.54 XLPE 1.4 19.7
2x70+70 19/2.15 | 12/2.15 | 7/2.15 XLPE 1.4 26.1
2x95+95 19/2.54 | 12/2.54 | 7/2.54 XLPE 1.6 30.5
3x70+70 19/2.15 | 12/2.15 | 7/2.15 XLPE 1.4 29.7
3x95+95 19/2.54 | 12/2.54 | 7/2.54 XLPE 1.6 34.6
Product Specifications
Product Name: Compact ABC Conductor Cable
Voltage: U0/U = 0.6/1KV
Technical Data: 1. Maximum operating temperature 90 degrees. 2. Maximum short circuit temperature 250 degrees
Application Field: 1. Areas where underground networks are expensive. 2. Electrification of rural areas
Road Conductor Type: 1. AAC: all aluminum bare wire. Bare conductor of ASC: aluminum strand.
2. AAAC: all aluminum alloy bare conductor. Bare conductor of AASC: aluminum alloy stranded wire.
3. ACSR: steel core aluminum wire
Product Images
Compact ABC Conductor Cable installation and close-up view ABC Cable construction and conductor details Overhead aerial line application of ABC cable

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Minfeng Cable Group Co., Ltd
Location Room 3101, Huafa International Building, Hanyang District, Wuhan City, Hubei Province.
Contact Person Fannie Fang

Request A Quote

Please check your email address.
Your message must be at least 20 characters.