ASTM A249 Welded Austenitic Stainless Steel Tube For Heat Exchanger Boiler Service
ASTM A249 / A249M is a standard specification issued by ASTM International for welded austenitic stainless steel tubes used in boilers, superheaters, heat exchangers, condensers, and hydraulic systems. These tubes are manufactured using GTAW or ERW processes and are supplied in the solution annealed condition to ensure corrosion resistance and high-temperature strength.
This product covers common grades such as TP304, TP304L, and TP304H, making it particularly suitable for high-temperature, high-pressure applications in heat exchangers and boiler tube bundles.
| Parameter | Range / Details |
|---|---|
| Standard | ASTM A249 / ASME SA249 |
| Manufacturing Type | Welded (ERW / GTAW); Heavily Cold Worked (HCW) optional |
| Available Grades | TP304, TP304L, TP304H, TP309S, TP310S, TP316, TP316L, TP316H, TP321, TP347, TP348, and others |
| Outside Diameter (OD) | 6.0 mm – 304.8 mm (0.236″ – 12″) (Other dimensions permitted if all standard requirements are met) |
| Wall Thickness (WT) | 0.4 mm – 8.1 mm (0.015″ – 0.320″) |
| Length | Fixed length or random length (as specified) |
| Delivery Condition | Annealed & Pickled (AP), Bright Annealed (BA), Polished, Cold Drawn |
| Surface Finish | BA, 2B, No.4, No.1, No.3, No.8, 8K, HL, 2D, 1D, Mirror Polished, 180G, 320G, 400G, etc. |
| Non-Destructive Testing | 100% Eddy Current Test (ET) or Hydrostatic Test (per A1016 requirements) |
| Value-Added Services | Cutting to length, Beveling, Threading, Polishing, Bending, Tube expansion |
| Grade | C ≤ | Mn ≤ | P ≤ | S ≤ | Si ≤ | Cr | Ni |
|---|---|---|---|---|---|---|---|
| TP304 | 0.08 | 2.00 | 0.045 | 0.030 | 1.00 | 18.0–20.0 | 8.0–11.0 |
| TP304L | 0.035 | 2.00 | 0.045 | 0.030 | 1.00 | 18.0–20.0 | 8.0–12.0 |
| TP304H | 0.04–0.10 | 2.00 | 0.045 | 0.030 | 1.00 | 18.0–20.0 | 8.0–11.0 |
| TP316 | 0.08 | 2.00 | 0.045 | 0.030 | 1.00 | 16.0–18.0 | 11.0–14.0 (Mo 2.0–3.0) |
| TP321 | 0.08 | 2.00 | 0.045 | 0.030 | 1.00 | 17.0–19.0 | 9.0–12.0 (Ti ≥ 5*C%) |
Grade Notes:
“H" grades (TP304H / TP316H / TP321H / TP347H) are specifically designed for high-temperature service (e.g., superheaters and reheaters), offering improved creep rupture strength.
“L" grades (TP304L) have lower carbon content, providing better resistance to intergranular corrosion after welding.
| Grade | Tensile Strength (MPa) min | Yield Strength (MPa) min | Elongation % min |
|---|---|---|---|
| TP304 / TP304H | 515 | 205 | 35 |
| TP304L | 485 | 170 | 35 |
| TP316 / TP316H | 515 | 205 | 35 |
| TP321 | 515 | 205 | 35 |
| TP347 | 515 | 205 | 35 |
Heat Treatment Requirement: Tubes shall be supplied in the solution annealed condition, typically heated to a minimum of 1900°F (1040°C) followed by rapid cooling.
| Parameter | Tolerance |
|---|---|
| Outside Diameter (OD) | ±0.2mm (or as agreed) |
| Wall Thickness (WT) | ±10% (or as agreed) |
| Length | ±10mm |
| Industry | Specific Application | Recommended Grade |
|---|---|---|
| Boilers & Superheaters | High-pressure steam lines, reheater tube bundles | TP304H, TP316H, TP321H |
| Heat Exchangers | Shell-and-tube, plate heat exchanger cores | TP304/L, TP316/L |
| Condensers | Power plant, chemical plant, condenser tube bundles | TP304, TP316 |
| Hydraulic & Pneumatic Systems | Precision hydraulic tubing | TP304/L (cold drawn) |
| Petrochemical | Process furnace tubes, catalyst lines | TP321, TP347 |
| Food & Pharmaceutical | Sanitary heat exchangers, sterile piping | TP304/L (polished/electropolished ID) |
| Nuclear Power | Auxiliary piping systems | TP304H (special requirements) |
| Feature | Advantage |
|---|---|
| Uniform wall thickness | High-dimensional accuracy, stable heat transfer efficiency |
| Smooth inner surface | Low pressure drop, reduced fouling, suitable for clean media |
| Cost-effective | More economical than seamless tubes for equivalent sizes |
| High customizability | Flexible production of small-diameter, thin-wall tubes |
| Reliable NDT | Welds can be 100% Eddy Current or Radiographic tested |
All tubes are tested in accordance with ASTM A1016/A1016M general requirements, including:
-
Chemical analysis (per heat)
-
Tensile test
-
Flattening test
-
Flaring test
-
Reverse flattening test (if applicable)
-
Non-Destructive Testing:
-
100% Eddy Current Test (ET)
-
or 100% Hydrostatic Test
-
Optional: Radiography (RT) for critical welds
-
Certificates Available:
-
Manufacturer’s Test Certificate (EN 10204 3.1)
-
Third-party inspection report (SGS, BV, TUV – upon request)
-
Heat treatment records
-
100% Radiography Test Report (if applicable)
-
DFARS compliance statement (if required)
| Finish Code | Description | Typical Application |
|---|---|---|
| 1D / No.1 | Hot rolled, annealed & pickled | General industrial heat exchangers |
| 2D | Cold rolled, dull finish | Moderate surface requirements |
| 2B | Cold rolled, bright finish | General bright surface |
| BA | Bright Annealed (protective atmosphere) | Clean, demanding applications |
| No.4 | Brushed finish (120-320 grit) | Sanitary, food grade |
| No.8 / Mirror | High gloss reflective | Decorative, semiconductor |
| Electropolished | Removes micro-burrs, enhances passivation | Pharmaceutical, biotechnology |
-
Packaging: PE fabric bundles, plywood wooden cases, or standard seaworthy export packing
-
Protection: Plastic caps on ends (if applicable), moisture-proof lining inside
-
Marking: Grade, size, heat number, standard clearly labeled
-
Port of Loading: As agreed (e.g., Qingdao, Shanghai – major ports)
The following requirements should be specified by the purchaser at the time of ordering:
-
Quantity (feet, meters, or number of lengths)
-
Name of material – Welded tubes (WLD) or Heavily Cold Worked tubes (HCW)
-
Grade (per Standard Table 1)
-
Size (outside diameter and nominal wall thickness)
-
Length (specific or random)
-
Optional requirements (e.g., special finish, testing)
-
Test report required
-
Specification designation (ASTM A249/A249M)
-
Special requirements and supplementary requirements (if any)
1. What is the difference between ASTM A249, A269, and A213?
| Standard | Manufacturing Type | Primary Application |
|---|---|---|
| A249 | Welded | Boilers, superheaters, heat exchangers, condensers |
| A269 | Seamless or Welded | General service, instrumentation |
| A213 | Seamless | Boilers, superheaters, heat exchangers |
2. How does TP304H differ from TP304 in high-temperature performance?
TP304H has a controlled carbon content of 0.04–0.10% (higher than ≤0.08% for standard TP304) and undergoes specific heat treatment, resulting in improved creep rupture strength for continuous service above 550°C.
3. Can welded tubes be used in high-pressure heat exchangers?
Yes. Provided they meet the standard’s requirements for 100% Eddy Current or Radiographic testing, and pass flattening/flaring tests, welded tubes are widely used in heat exchangers and condensers with design pressures exceeding 10 MPa.
4. What is the minimum order quantity?
It depends on size and wall thickness. Small-diameter, thin-wall tubes for heat exchangers (e.g., 19.05*1.65mm) typically have lower MOQs. Please provide your specific requirements for evaluation.
5. Can you provide a 3.2 certificate?
Yes, but this usually involves additional cost and may require witnessed testing. Please specify the need for an EN 10204 3.2 certificate, and we will arrange for an accredited third-party to perform the required tests.
6. What internal surface roughness can be achieved for polished tubes?
Mechanical polishing can achieve Ra ≤ 0.4 µm; electropolishing can achieve Ra ≤ 0.2 µm, suitable for high-purity media and pharmaceutical-grade applications.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.