HGZT-M 50 kVA Partial Discharge Testing System with 150 kV Output and 0.1 pC Sensitivity for Power Equipment

Price Negotiable
Price: $27,500 – $118,000
MOQ: ONE
Delivery Time: 25-30 work days
Brand: Huagao
Product Description
HGZT-M Power Equipment Partial Discharge Testing System
1. Power Equipment Partial Discharge Test Control Panel HGZT-M

The installation location should be level with a slope less than 5°.

Local discharge level (spatial interference)
less than 2pc
Partial discharge interference (power supply voltage source)
less than 10pc
Protection features
overcurrent protection ; Breakdown and flashover protection; Zero position protection upon startup; Power failure protection; Linkage protection for the cooling fan
System control
enables control of both three-phase power supplies and single-phase industrial-frequency power systems
Software functionality
performs testing through communication with the partial discharge detector. It has a one-click feature to generate test reports. Supports third-party access and database data interaction.
2. Non-localized variable-frequency power supply TP-50
Power supply voltage and frequency
Three-phase 400V ±10%; 50Hz
Power supply capacity
greater than 50 kVA
Rated output power
30 kW
Rated output voltage
line voltage 0–310 V, continuously adjustable (phase angle difference 120° ± 1°)
Rated output current
Line current 75A
Output waveform
pure sine wave
Phase count
Three-phase four-wire system
Output waveform distortion rate
≤1.0%
Output voltage instability
≤1.0%
Three-phase output symmetry
Three-phase line voltage imbalance ≤2%; The phase deviation angle difference between the three phases is ≤1.0%
Cooling method
Forced air cooling
Frequency adjustable range
50Hz to 300Hz
Output frequency resolution
0.1 Hz
Output frequency instability
≤0.5%
Noise level
≤80 dB
3. Non-localized discharge excitation transformer ZB3-50KW
Rated capacity
50 kVA
Input side rated voltage
320V
Phase configuration
three-phase four-wire system, YN-D
Input side rated current
50A
Rated output voltage
900V
Insulation level
Low-voltage winding to ground: 3 kV/1 min; The high-voltage winding induces a voltage of 1.2 times for 1 minute
Rated frequency
50–300 Hz
Partial discharge level
The partial discharge quantity at rated voltage is ≤5 pC
4. No partial discharge test transformer WDJ-50KVA/150KV
Rated capacity
50 kVA
Input side rated voltage
400V
Phase count
Single-phase
Input side rated current
132 A
Output side rated voltage
150 kV
Insulation level
Low-voltage winding to ground: 5 kV/1 min; The high-voltage winding induces a voltage of 1.2 times for 1 minute
Insulation method
sulfur hexafluoride gas
Rated frequency
50–300 Hz
Partial discharge level
The partial discharge quantity at rated voltage is ≤5 pC
5. No partial discharge coupling capacitor WF-300/150
Rated voltage
150 kV
Pressure rating
150 kV
Operating frequency
50–300 Hz
Capacitance
C1 = 300 pF ± 5%
Partial discharge level
<5 pC at rated voltage
6. No partial discharge protection resistor HCWR-10/150
Rated voltage
150 kV
Rated current
0.2 A
Operating frequency
50–300 Hz
Resistance
10 kΩ ±5%
Partial discharge level
<5 pC at rated voltage
7. No partial discharge coupling capacitor HCWF-300/60
Rated voltage
60 kV
Pressure rating
60 kV
Operating frequency
50–300 Hz
Capacitance
C1 = 300 pF ± 5%
Partial discharge level
<5 pC at rated voltage
8. Localized discharge power isolation filter HCF-80
Rated voltage
440 V AC
Rated current
80 A
Filter frequency band range
10–300 kHz
Rated capacity
50 kVA
Insulation method
Dry type
Partial discharge level
<5 pC at rated voltage
9. Digital partial discharge detector PD-9104
Number of channels
4 independent channels
Sampling rates
1M,5M, or 10M available
Sampling accuracy
12-bit
Range switching
6 levels-40 dB, -20 dB, 0 dB, 20 dB, 40 dB, and 60 dB
Measurement frequency band
3 dB bandwidth from 10 kHz to 1 MHz
Digital filtering
Select from 10 kHz to 1 MHz
Program-controlled filter segmentation
Low-end frequencies: 10 kHz, 20 kHz, 40 kHz, 80 kHz High-frequency range: 100 kHz, 200 kHz, 300 kHz, 400 kHz
Nonlinear error within this range
5%
Measurement range
0.1 pC to 10,000 pC
Sensitivity
0.1 pC
Test sample capacitance range
6 pF to 250 µF
Test power supply frequency range
50–500 Hz
10. Partial discharge test accessory PD-02
Accessorie
Square wave calibrator, impedance input unit, discharge rod
Similar Products

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Wuhan HUAGAO Huineng Electrical Technology Co., Ltd.
Location 707, Building 6, Guanggu Science and Technology Port Industrial Park, North Huashi Yuan Road, Guanshan Avenue, East Lake High-Tech Development Zone, Wuhan City, Hubei Province, China
Contact Person wangchanglin

Request A Quote

Please check your email address.
Your message must be at least 20 characters.