Chilled Water CRAC Unit 100kW Constant Temperature & Humidity For Centralized Cooling Computer Room
Price:
$23000
MOQ:
1
Delivery Time:
5-8 weeks
Brand:
Hailos
Product Description
Product Introduction
This 100kW chilled water CRAC unit is designed for large centralized cold source supporting projects. It realizes all-round constant temperature and humidity adjustment through cooling, heating, humidification and dehumidification modules. Independent refrigeration loop design enhances operational stability, single-loop failure will not cause the whole machine to stop running. Reserved standard communication interface for centralized access to machine room monitoring platform, convenient for unified operation and maintenance management.
Typical Applications
- Small to Medium Server Rooms & Data Centers
- UPS and Battery Storage Rooms
- Telecommunication Base Stations & 5G Hubs
- Medical Imaging Suites (MRI/CT)
- Industrial Automation & PLC Control Rooms
Technical Parameters
| Model | Indoor Units(single drive) | Q30 | Q40 | Q50 | Q60 | Q70 | Q80 | Q90 | Q100 | Q110 | Q120 | Q130 | Q140 | Q150 | Q160 | Q180 | Q200 | |
| Cooling capacity |
Cooling capacity |
KW | 31.5 | 41.6 | 51.8 | 62.2 | 71.8 | 81.4 | 91.5 | 101.4 | 112.2 | 121.8 | 131.6 | 140.5 | 152.6 | 162.4 | 182.6 | 202.5 |
| Sensible cooling capacity |
KW | 28.2 | 37.8 | 46.4 | 55.7 | 64.7 | 74.3 | 82.8 | 91.3 | 100.9 | 110.8 | 118.7 | 127.4 | 137.9 | 146.7 | 164.8 | 178.2 | |
| Frozen water |
Water flow | m3/h | 4.9 | 6.6 | 8.3 | 9.9 | 12 | 13.7 | 14.9 | 16.2 | 18.2 | 19.8 | 21.6 | 23 | 24.4 | 25.9 | 29.7 | 34.4 |
| Pressure drop | kPa | 48 | 42 | 58 | 48 | 50 | 48 | 58 | 63 | 70 | 72.5 | 74.8 | 72.5 | 76 | 82 | 89 | 98.5 | |
| Fan | Type | EC fans/AC | ||||||||||||||||
| Wind flow | m3/h | 9200 | 9800 | 12500 | 14000 | 18000 | 20500 | 21500 | 22500 | 25000 | 27500 | 30000 | 32000 | 35000 | 38000 | 40000 | 42200 | |
| Quantity | 1 | 1 | 1 | 1 | 1 | 2 | 2 | 2 | 2 | 2 | 2 | 2 | 3 | 3 | 3 | 3 | ||
| Heater | Type | PTC Ceramic Electric Heating | ||||||||||||||||
| Heating capacity |
KW | 6 | 6 | 6 | 9 | 9 | 9 | 9 | 9 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 | |
| Humidifier | Type | Electrode Humidification | ||||||||||||||||
| Humidification | Kg/h | 5 | 5 | 5 | 8 | 8 | 8 | 8 | 8 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | 15 | |
| Air Filter | Plate G4 filter | |||||||||||||||||
| Conditioner Size |
single coil Width | mm | 1600 | 1600 | 1600 | 1600 | 1600 | 1750 | 1750 | 1750 | 1750 | 1750 | 1750 | 1750 | 1750 | 1750 | 1750 | 1750 |
| Depth | mm | 850 | 850 | 850 | 850 | 850 | 850 | 850 | 850 | 850 | 850 | 850 | 850 | 850 | 850 | 850 | 850 | |
| Height | mm | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | |
| Connection Tube |
Water Tube | mm | Dn32 | Dn32 | Dn40 | Dn40 | Dn40 | Dn40 | Dn50 | Dn50 | Dn50 | Dn50 | Dn50 | Dn50 | Dn65 | Dn65 | Dn65 | Dn65 |
| Drain Tube | mm | φ32 | φ32 | φ32 | φ32 | φ32 | φ32 | φ32 | φ32 | φ32 | φ32 | φ32 | φ32 | φ32 | φ32 | φ32 | φ32 | |
| Humidifierinletpip | ein | φ20 | φ20 | φ20 | φ20 | φ20 | φ20 | φ20 | φ20 | φ20 | φ20 | φ20 | φ20 | φ20 | φ20 | φ20 | φ20 | |
| Weight | single coil | kg | 282 | 324 | 385 | 406 | 523 | 566 | 597 | 615 | 636 | 656 | 656 | 680 | 788 | 810 | 866 | 923 |
| Power distribution parameters |
Power | 380V / 50HZ / 3N~ | ||||||||||||||||
| Recommended circuit breaker |
D25 | D25 | D25 | D40 | D40 | D40 | D40 | D40 | D50 | D50 | D50 | D63 | D63 | D63 | D63 | D63 | ||
| Wiring | mm2 | 6 | 6 | 6 | 6 | 10 | 10 | 10 | 10 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | 16 | |
| Remarks | 1. Test conditions: return air temperature 24°C, relative humidity 50%, chilled water supply 7°C, return water 12°C 2. The size of the unit does not include the height of the hood. The standard height of the hood is 400mm, and other sizes are optional; 3. The water flow regulating valve is equipped with a two-way valve as standard, and a three-way valve is optional; 4. If the residual pressure outside the machine needs to exceed 400Pa, please contact our company; 5. If the data is not listed in the data sheet, please contact our company; 6. If you have other customization requirements, please contact our company. |
|||||||||||||||||
Product Photo
Certificate ( CE /ISO )
Packing
Project Case
FAQ
Q1: Who is Zhengzhou Hailos Refrigeration Equipment Co.,ltd?
A1: We are a professional factory specializing in R&D, production and export of precision air conditioners and industrial chillers, located in Zhengzhou, China. We focus on high-precision cooling equipment for data centers, laboratories, laser processing, electroplating, battery factories, medical rooms and industrial production lines. All units are strictly tested before delivery, with complete international certifications for global market sales.
Q2: What is your MOQ (Minimum Order Quantity)?
A2: 1 unit for standard models is acceptable; for customized non-standard machines, MOQ depends on configuration. Distributors with bulk orders get extra factory discount.
Q3: Do you accept factory inspection?
A3: Yes, warm welcome customers to visit our workshop and test equipment on site. We support live video factory tour if you cannot come to China temporarily.
Q4: Where are Hailos precision air conditioners widely used?
A4: Server data room, communication base station, medical lab, testing laboratory, battery workshop, optical equipment room, clean room, electronic manufacturing workshop, industrial control cabinet cooling.
Q5: Can precision air conditioner work all year round without shutdown?
A5: Yes. Our precision cooling units adopt heavy-duty scroll compressor, EC energy-saving fan and independent control system, designed for 24-hour non-stop operation all year long, low failure rate.
Q6: Can I adjust temperature and humidity remotely?
A6: Standard models support Modbus communication to connect with monitoring system; optional WiFi remote control module for mobile phone real-time parameter checking, alarm reminder and parameter modification.
Q7: What refrigerants do you use for precision AC?
A7: Mainly eco-friendly R410A, R134a; we can replace with R32, R290 low-GWP refrigerants to meet local environmental regulations in your country.
Q8: Do you support OEM / ODM customized service?
A8: Yes, full OEM & ODM service available: custom unit size, voltage (380V/220V/415V 50/60Hz), brand logo, control panel language (English, Spanish, Russian, Vietnamese), special refrigerant, remote monitoring system, cabinet color. We can design new model drawing based on your working conditions.
ctant temperature and humidity controltype (model: P xxKA)
Similar Products
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Zhengzhou Hailos Refrigeration Equipment Co.,ltd
Location
No. 58 Arear F, 2nd Floor, Building 2, No.2,52 Hongsong Road, Zhengzhou High-tech Industrial Development Zone, Henan Province,China