20kW Air Cooled Room Precision CRAC Unit With SNMP Modbus Communication For IDC Server Room
Product Introduction
This 20kW air-cooled room precision CRAC unit is equipped with standard SNMP and Modbus communication interfaces, supporting docking with BMS and data center centralized monitoring system. Adopts Ziehl-Abegg energy-saving EC fans to cut power consumption under partial load. Independent constant temperature and humidity system prevents static electricity and overheating faults of IT equipment. Multiple safety protections realize long-term unattended stable operation.
Efficient and energy-saving
- Large air volume and small difference design, high sensible heat ratio, and low energy consumption.
- Efficient flexible scroll compressor.
- Efficient large-area copper tube finned evaporator.
- Structural optimization design to reduce wind resistance, power, and noise.
High reliability
- 24 hours × 365 days of continuous uninterrupted operation, with a design life of 10 years.
- All accessories have undergone strict inspection and testing, with stable performance.
- Adopting PTC heater, safe and reliable.
- Multiple protection functions ensure reliable operation of the unit.
Compact
- Modular design of unit structure, flexible assembly.
- Multiple return air modes are available to adapt to various application scenarios.
- Compact and optimized design, saving space.
- Full frontal maintenance design, saving maintenance space.
Intelligent control
- Chinese/English LCD large display screen, displaying the operating status of various components of the environmental temperature and humidity meter unit.
- Special controller for constant temperature and humidity air conditioning, advanced PID control technology.
- Complete protection and alarm functions, master level diagnostic functions.
- RS485 intelligent communication interface, easy to achieve remote monitoring and online group control.
Typical Applications
- Small to Medium Server Rooms & Data Centers
- UPS and Battery Storage Rooms
- Telecommunication Base Stations & 5G Hubs
- Medical Imaging Suites (MRI/CT)
- Industrial Automation & PLC Control Rooms
| Category | Parameter | Unit | S04 | S05 | S07 | S10 | S12 | S17 | S20 | S23 | S29 |
| Cooling | Total Capacity | kW | 4.4 | 5.5 | 8.1 | 10.4 | 12.8 | 16.9 | 20.1 | 25.6 | 31.3 |
| Sensible Capacity | kW | 4.3 | 5.2 | 7.6 | 10 | 12.5 | 16.1 | 19 | 23.1 | 30.3 | |
| Fan | Air Flow | m3/h | 1350 | 1550 | 2300 | 2800 | 3000 | 5250 | 5800 | 6150 | 10040 |
| Heater | Capacity | kW | 3 | 3 | 3 | 4 | 6 | 6 | 10 | 12 | 12 |
| Humidifier | Capacity | kg/h | 3 | 3 | 3 | 4 | 4.5 | 4.5 | 9 | 9 | 9 |
| Unit Size | Width | mm | 750 | 750 | 750 | 750 | 750 | 750 | 1200 | 1200 | 1200 |
| Depth | mm | 500 | 500 | 500 | 500 | 500 | 500 | 650 | 650 | 650 | |
| Height | mm | 1800 | 1800 | 1800 | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | |
| Outdoor | Model | - | S04W | S05W | S07W | S10W | S12W | S17W | S20W | S23W | S29W |
| Weight | kg | 30 | 35 | 40 | 50 | 50 | 60 | 80 | 100 | 120 |
| Category | Parameter | Unit | S35 | S41 | S47 | S58 | S66 | S83 | S99 |
| Cooling Capacity | Total Capacity | kW | 37 | 45.8 | 53.7 | 60.1 | 70.3 | 86.3 | 104.6 |
| Sensible Capacity | kW | 35.1 | 43.4 | 49 | 58.3 | 68.9 | 79.5 | 95.2 | |
| Compressor | Type | Vortex | Vortex | Vortex | Vortex | Vortex | Vortex | Vortex | |
| Quantity | 2 | 2 | 2 | 2 | 2 | 2 | 2 | ||
| Fan | Type | AC/EC Centrifugal | AC/EC Centrifugal | AC/EC Centrifugal | AC/EC Centrifugal | AC/EC Centrifugal | AC/EC Centrifugal | AC/EC Centrifugal | |
| Air Flow | m3/h | 11140 | 12470 | 13550 | 14580 | 15470 | 21520 | 24000 | |
| Quantity | 2 | 2 | 2 | 2 | 2 | 2 | 2 | ||
| Optional Accessories | Heating Capacity | kW | 18 | 18 | 18 | 24 | 24 | 30 | 30 |
| Humidifying Capacity | kg/h | 9 | 13 | 13 | 13 | 13 | 13 | 13 | |
| Unit Size | Width | mm | 1200 | 1200 | 1750 | 1750 | 1750 | 1750 | 2000 |
| Depth | mm | 650 | 650 | 850 | 850 | 850 | 850 | 1000 | |
| Height | mm | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | 1900 | |
| Connecting Pipe | Gas Pipe | mm | 22*2 | 22*2 | 22*2 | 22*2 | 22*2 | 25*2 | 28*2 |
| Fluid Pipe | mm | 19*2 | 19*2 | 19*2 | 19*2 | 19*2 | 19*2 | 22*2 | |
| Drain Pipe | mm | φ25 | φ25 | φ25 | φ25 | φ25 | φ25 | φ32 | |
| Water Inlet Pipe | in | φ20 | φ20 | φ20 | φ20 | φ20 | φ20 | φ20 | |
| Weight | Total Weight | kg | 320 | 360 | 460 | 560 | 620 | 900 | 1000 |
| Distribution | Power Supply | 380V / 50Hz | 380V / 50Hz | 380V / 50Hz | 380V / 50Hz | 380V / 50Hz | 380V / 50Hz | 380V / 50Hz | |
| Circuit Breaker | D | D100 | D100 | D100 | D100 | D120 | D125 | D200 | |
| Wiring | mm2 | 16 | 16 | 16 | 25 | 25 | 25 | 35 | |
| Outdoor Unit | Model | S31W | S41W | S47W | S58W | S66W | S83W | S99W | |
| Quantity | 2 | 2 | 2 | 2 | 2 | 2 | 2 | ||
| Weight | kg | 80 | 80 | 100 | 100 | 120 | 150 | 200 | |
| Wiring | mm2 | 3*2.5/2 | 3*2.5/2 | 3*2.5/2 | 3*2.5/2 | 3*2.5/2 | 3*2.5/2 | 3*2.5/2 | |
| Width | mm | 850 | 850 | 850 | 850 | 850 | 850 | 2100 | |
| Depth | mm | 550 | 550 | 550 | 550 | 550 | 550 | 1100 | |
| Height | mm | 1600 | 1600 | 1600 | 1600 | 1600 | 1600 | 1100 |
Project Case
A3: Yes, warm welcome customers to visit our workshop and test equipment on site. We support live video factory tour if you cannot come to China temporarily.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.