High Volume 4-72 Centrifugal Fan Type C Belt Driven Backward Inclined 28CM To 200CM

Price Negotiable
Price: Negotiable
MOQ: 1 set
Delivery Time: 2 two days for sampe order and 10 days for bulk order
Brand: Popula
Product Description

4-72 C High Quality Big Centrifugal Fan

· Belt-driven makes easily control speed.

· A strong body with pure copper Increases the whole machine's life at an affordable centrifugal blower fan price.

· This backward inclined centrifugal fan is multi-functional in many areas.

· The air inlets of the fan are also made with a fixed structure, located at the side of the fan, in a curved shape with a section of axial parallel to ensure that air can smoothly enter the impeller more efficiently.

· This backward inclined centrifugal fan can be used in ordinary indoor ventilation, delivering air and other gas that is non-hypergolic, harmless to humans, and non-corrosive to metal.

· The air which is delivered by this product is forbidden to contain stickum, as well as dust and hard particles.

 

4-72-C Model Features:

 

Material Properties

 

4-72-C type backward inclined centrifugal fan is designed to fit the equipment of heavy industries, which can burn any kind of coal base, and is equipped with smoke and dust-removal device. It is applicable as long as the air volume and the performance fit the condition. However, the highest temperature shall not exceed 130℃. Our company can provide the stainless steel heat boiler centrifugal fan when the temperature of air must exceed 130℃. It can be used on many occasions to transfer materials and ventilation and improve motivation to systems.

 

Selection

 

The backward inclined centrifugal fan has a single inlet, model No. Has No6,7,8,10,12,14,16, these kinds.


The centrifugal fan can be made into two forms: left-hand rotated and right-hand rotated. Face the fan from one end of the drive set. If the impeller rotates clockwise, we called it right-hand rotated, in short we use “right” for expression. If the impeller rotates anticlockwise, we call it left-hand rotated; in short, we use “left” for expression. 


The position of the fan's air outlet is indicated by the angle of the air outlet of the housing. “left” and “right” can be made into 0°,90°, 180 °, or three angles. 

 

Fan Structure

The boiler centrifugal fan is made of the impeller, housing, air inlet, driven set, regulating door, and other parts. 


The impeller has 12 backward inclined plate blades of 16Mn material, which are welded in the arc cone impeller cover and in the middle of the plate-shaped disc and are corrected by dynamic balance. Therefore, it runs smoothly, has high strength and wear resistance, and has a long service life.

 

Model Power(kW) Rotation(r/min) Volume(m³/h) Pressure(Pa)
6C 1.1~30 800~2900 3684~27167 346~4766
7C 4~45 1000~2000 7312~40475 468~3886
8C 4~55 900~1800 9823~51866 631~3963
9C 11~55 1000~1800 15540~56605 897~3202
10C 5.5~30 630~1050 17571~43722 475~1902
11C 30~75 1000~1350 37122~70145 1457~3358
12C 22~110 800~1350 33856~91067 1104~3997
14C 30~160 630~1200 48217~143910 932~4298
16C 37~200 560~900 63974~193518 961~3565
18C 55~200 560~850 91087~221730 1224~3069
20C 55~200 450~710 100400~174890 970~3069



Q1: What are the main applications of the 4-72 fan?
A1: It is widely used for ventilation, air supply, and exhaust in factories, warehouses, commercial buildings, and other environments.

Q2: What is the advantage of the belt-driven (Type C) design?
A2: The belt-driven design allows for flexible speed control, making it suitable for a wide range of airflow and pressure requirements.

Q3: How do I choose the right model for my application?
A3: Consider the required airflow, pressure, speed, and power. The series offers a wide range of models with different capacities.

Q4: Is the fan suitable for continuous operation?
A4: Yes, the fan is designed for long-term continuous use in various environments.

Q5: What maintenance is required for the 4-72 fan?
A5: Regular cleaning of the impeller and casing, as well as periodic checks of the belt drive system and motor, are recommended to ensure optimal performance.

Q6: Can the fan be used for both supply and exhaust ventilation?
A6: Yes, the fan is suitable for both supply and exhaust applications in various ventilation systems.

Q7: What certifications does the 4-72 series have?
A7: The series meets international quality standards. CE-certified versions are available for European customers.

Q8: Is the fan easy to install?
A8: Yes, the standard design allows for easy installation in various ventilation systems.

Q9: What is the power range of the series?
A9: The series includes models with power ranging from 1.1kW to 200kW.

Q10: What is the speed range of the series?
A10: The series includes models with speeds ranging from 450r/min to 2900r/min.


Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Popula Group Company Limited
Location No.3, Tangxin 3rd Road, Xincheng, Xiaotang, Shishan Town, Nanhai District, Foshan, Guangdong, China
Contact Person kevin

Request A Quote

Please check your email address.
Your message must be at least 20 characters.