Belt Drive Industrial Boiler Centrifugal Fan High Flow Centrifugal Induced Draft Fan

Price Negotiable
Price: Negotiable
MOQ: 1 set
Delivery Time: 2 two days for sampe order and 10 days for bulk order
Brand: Popula
Product Description

Y5-48 High Temperature Boiler Induced Draft Centrifugal Fan

 

* Model No.4C~12.5C of Y5-48 boiler induced draft fan consists of heat-resistant backward curved airfoil impeller, thickened high-temperature carbon steel welded volute casing, streamlined circular air inlet and belt-driven separated motor assembly. ·

* The impeller is assembled with multiple high-temperature resistant backward curved blades plus front and rear wheel disc; all impeller assemblies pass strict static & dynamic balance calibration to realize steady low-vibration operation under high-temperature flue gas working condition. ·

* These boiler smoke exhaust blowers are fabricated with premium carbon steel plate; optimized internal volute flow channel reduces flue gas flow loss and guarantees stable exhausting efficiency under variable boiler operating load. ·

* Belt pulley transmission structure features compact layout and flexible speed matching, convenient for later maintenance of belt and motor replacement. ·

* Curved streamlined air inlet guides high-temperature flue evenly into impeller and improves overall smoke exhausting efficiency.

 

Y5-48 Model Features:

 

Material Properties

 

Featured by outstanding heat resistance, compact overall dimension and stable exhaust performance curve, Y5-48 series fans are specially matched supporting exhaust equipment for 1~20t/h industrial coal-fired boiler and civil boiler equipped with flue gas desulfurization and dust removal device.

 

All specifications can be equipped with standard Y-series three-phase asynchronous motor; B-Y5-48 explosion-proof variant fitted with YB flameproof motor is optional for special volatile-fuel boiler on request.

 

F-Y5-48 full stainless steel anti-corrosion customized version is available for working condition where inlet flue temperature exceeds 250℃, keeping identical airflow parameters and foundation mounting dimension as standard carbon steel Y5-48 fan.

 

Benefits

 

Standard Y5-48 fan is designed for extracting boiler high-temperature flue gas; explosion-proof B-Y5-48 can exhaust combustible volatile flue gas from special fuel-fired boiler. Conveyed flue gas shall not contain sticky impurities, dust and hard particulate content is controlled ≤150mg/m³, maximum allowable inlet medium temperature shall not exceed 250℃; dust removal equipment with purification efficiency no less than 85% must be installed at fan inlet.

 

Fan Structure

 

B-Y5-48 explosion-proof induced draft fan shares consistent technical performance, parameter selection standard, overall outline dimension and foundation installation size with ordinary standard Y5-48 fan, only the driving motor is replaced with explosion-proof specification.

 

Model Selection

 

The series covers rotating speed range from 1000r/min up to 3550r/min with matched power ranging 2.2~110kW, diversified speed-power collocation realizes wide flow and full pressure scope to satisfy different tonnage boiler’s smoke exhausting and pipeline resistance requirements.

 

Model Power(kW) Rotation(r/min) Volume(m³/h) Pressure(Pa)
4C 5.5/4/3/2.2 3550/3150/2800/2500 2065~5564 2221~742
5C 11/7.5/5.5/4 3150/2800/2500/2240 3772~9851 2819~964
6.3C 22/15/11/7.5/30 2800/2500/2240/2000 6737~25619 3545~2253
8C 22/15/11/7.5 1800/1600/1400 9656~44634 2657~2958
10C 55/37/22 1600/1400/1250 15451~34715 3531~1419
12.5C 110/75/55/37 1400/1250/1120/1000 24143~67803 4234~1419

 

 

Q1: What are the main applications of the Y5-48 fan?
A1: It is designed for use with 1–20t/h industrial and civil boilers equipped with dust removal systems.
 
Q2: What temperature conditions can the fan withstand?
A2: The flue gas temperature at the fan inlet must not exceed 250°C. Stainless steel versions are available for higher temperatures.
 
Q3: What dust removal requirements are there?
A3: A dust removal device with efficiency ≥85% must be installed before the fan to protect it from wear.
 
Q4: What is the drive type of the fan?
A4: The fan features a belt-driven C-type design, allowing for flexible speed control and maintenance.
 
Q5: How do I choose the right model for my boiler?
A5: Consider the boiler capacity, required airflow, static pressure, and installation space. The series offers a wide range of models with different capacities.
 
Q6: What maintenance is required for the Y5-48 fan?
A6: Regular inspections and maintenance are recommended, including checks of the motor, impeller, belt drive system, and dust removal equipment.
 
Q7: Is the fan suitable for continuous operation?
A7: Yes, the fan is designed for long-term continuous use in boiler ventilation systems.
 
Q8: What certifications does the Y5-48 series have?
A8: The series meets international quality standards. CE-certified versions are available for European customers.
 
Q9: Can the fan be used with boilers of different capacities?
A9: Yes, the series includes models suitable for boilers from 1t/h to 20t/h.
 
Q10: Is there a high-temperature version available?
A10: Yes, stainless steel high-temperature induced draft fans are available for applications where gas temperatures exceed 250°C.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Popula Group Company Limited
Location No.3, Tangxin 3rd Road, Xincheng, Xiaotang, Shishan Town, Nanhai District, Foshan, Guangdong, China
Contact Person kevin

Request A Quote

Please check your email address.
Your message must be at least 20 characters.