RVV 2x0.75mm2 2 Core Flexible Cable Stranded Copper Conductor PVC Sheathed
RVV-2*0.75mm² Flexible Control Cable 2 Core Stranded Copper Conductor PVC Insulated PVC Outer Sheathed
RVV 2×0.75 mm² Copper Conductor PVC Insulated & Sheathed Flexible Cord
Type: 60227 IEC 53 (RVV) · Voltage: 300/500 V · Standard: GB/T 5023.5-2008 / IEC 60227-5:2003 · Certification: CCC · Origin: Anhui, China
Cable Photo Show
1. Electrical & Structural Parameters

|
Category |
Parameter |
Value / Description |
|---|---|---|
|
Identification |
Type / Model |
60227 IEC 53 (RVV) — copper-core PVC-insulated PVC-sheathed flexible cord |
|
Common Name |
Light-duty PVC sheathed flexible cord ("soft sheathed wire") |
|
|
Number of Cores × Nominal CSA |
2 × 0.75 mm² |
|
|
Conductor |
Conductor Material |
Annealed bare copper (Class 5 flexible, per GB/T 3956 / IEC 60228) |
|
Conductor Construction |
24 / 0.20 mm (24 fine strands of 0.20 mm diameter) |
|
|
Conductor Shape |
Circular, stranded flexible |
|
|
Max. DC Resistance @ 20 °C |
≤ 26.0 Ω/km |
|
|
Insulation |
Insulation Material |
PVC/D type polyvinyl chloride compound |
|
Insulation Nominal Thickness |
0.6 mm |
|
|
Insulation Min. Thickness (thin point) |
≥ 0.4 mm |
|
|
Finished Core Outer Diameter |
≈ 2.35 ± 0.15 mm |
|
|
Sheath |
Sheath Material |
PVC/ST5 type polyvinyl chloride compound |
|
Sheath Nominal Thickness |
0.8 mm |
|
|
Sheath Min. Thickness (thin point) |
≥ 0.6 mm |
|
|
Dimensions |
Avg. Overall Diameter (round) |
5.7 mm (lower) ~ 7.2 mm (upper) |
|
Avg. Overall Diameter (flat) |
3.7×6.0 mm (lower) ~ 4.5×7.2 mm (upper) |
|
|
Reference Overall Diameter |
≈ 6.4 mm (round, typical) |
|
|
Approx. Weight |
40 ~ 52 kg/km (typical ≈ 46 kg/km) |
|
|
Electrical |
Rated Voltage (U₀/U) |
300/500 V (AC) |
|
Dielectric Withstand Test |
2000 V AC, 5 min, no breakdown |
|
|
Min. Insulation Resistance @ 70 °C |
≥ 0.011 MΩ·km |
|
|
Min. Insulation Resistance @ 20 °C |
≥ 20 MΩ·km |
|
|
Temperature |
Max. Continuous Conductor Temp. |
70 °C |
|
Short-Circuit Temp. (≤ 5 s) |
150 °C |
|
|
Min. Installation / Laying Temp. |
0 °C (warm cable if below; some compounds allow −15 °C) |
|
|
Mechanical |
Min. Bending Radius |
4 × overall diameter (cable OD < 25 mm) ≈ 23 ~ 29 mm |
|
Flame Retardant |
Passes GB/T 18380.12-2020 (IEC 60332-1), self-extinguishing |
|
|
IP Level |
IP40 (dust-proof / splash-resistant; protection depends on conduit/trunking) |
|
|
Physical Properties (PVC, before aging) |
Tensile strength ≥ 10.0 N/mm²; elongation at break ≥ 150% |
|
|
Aging (80±2 °C × 168 h) |
Tensile / elongation change rate within ±20% |
|
|
Color |
Core Colors |
Brown + Blue (standard IEC); Red/Black or customized available |
|
Sheath Color |
Black (standard); other colors available on request |
|
|
Packing |
Standard Length |
100 m / 200 m / 500 m per roll (custom lengths available) |
2. Current-Carrying Capacity Reference
|
Installation Condition |
Reference Ampacity* |
Notes |
|---|---|---|
|
2-core, single cable in free air (25 °C ambient) |
6 ~ 10 A (typical ≈ 10 A) |
Per IEC 60227-5 tabulated value ≈ 12 A (single, 20 °C conductor) |
|
2-core, bundled / in conduit (25 °C) |
≈ 8 A |
Apply ~20% derating for 2-core grouping |
|
With ambient 30 °C |
≈ 9.1 A |
×0.91 temperature correction |
|
With ambient 40 °C |
≈ 8.2 A |
×0.82 temperature correction |
|
With ambient 50 °C |
≈ 7.4 A |
×0.71 temperature correction (every +10 °C above 50 °C → −10%) |
* Reference values for PVC-insulated copper conductor at 70 °C temp. class; actual ampacity must be corrected for ambient temperature, grouping/bundling, conduit fill, and local wiring regulations. Do not use the uncorrected free-air value for enclosed/conduit installations.
Derived electrical reference (2×0.75 mm², 25 m two-wire run)
|
Quantity |
Calculated Value |
Interpretation |
|---|---|---|
|
Voltage drop @ 10 A, 220 V, 25 m run |
≈ 13.0 V (5.9% of 220 V) |
Within typical 3–6% tolerance at moderate load; for longer runs reduce current or upsize |
|
Usable real power @ 10 A, 220 V |
≈ 2.2 kW |
Practical upper bound for a single 2×0.75 mm² feed |
|
Voltage drop @ 3 A, 12 V DC, 25 m |
≈ 3.9 V |
Significant (~33%) — use thicker CSA for long 12 V runs |
|
220 V single-phase power ref. (2-core) |
≈ 1.3 ~ 1.8 kW (derated) |
Aligns with socket/lighting branch use |
3. Product Performance Introduction
The RVV 2×0.75 mm² is a light-duty, double-insulated flexible cord built around a Class 5 fine-strand annealed copper conductor (24/0.20 mm), giving it the softness and fatigue resistance required for connections that are repeatedly moved, bent, or dressed into compact enclosures. Each conductor is individually insulated with PVC/D compound (0.6 mm wall), the two cores are laid up together, and the assembly is enclosed in a PVC/ST5 outer sheath (0.8 mm) — producing either a round or flat cross-section depending on layup .
Electrical reliability. With a certified ≤ 26.0 Ω/km conductor resistance at 20 °C and a 2000 V AC / 5 min withstand proof test, the cable delivers stable, low-loss power transmission for low-power AC (300/500 V) and DC supply circuits while maintaining a safety margin well above normal operating voltage . The ≥ 0.011 MΩ·km insulation resistance at 70 °C keeps leakage current negligible across the service life .
Thermal performance. Rated for 70 °C continuous conductor temperature (150 °C short-circuit, 5 s max), the PVC/D + PVC/ST5 system is formulated for long-term thermal stability under indoor ambient conditions . At a conservative ≈ 10 A reference ampacity (2-core, corrected for grouping), it comfortably supplies typical 220 V socket, lighting, and low-power appliance branches up to ~1.3–2.2 kW, with voltage drop remaining within standard tolerance on runs up to ~25 m at rated current .
Mechanical & safety performance. The fine-strand construction survives repeated bending (minimum bend radius 4× overall diameter, ≈ 23–29 mm), while the outer sheath resists abrasion from pulling through conduit and minor crushing in trunking . The cable passes the GB/T 18380.12 (IEC 60332-1) single-cable vertical flame test, self-extinguishing once the ignition source is removed . PVC mechanical properties are verified before and after aging (80±2 °C × 168 h): tensile strength ≥ 10.0 N/mm², elongation ≥ 150%, with change rates within ±20% — confirming the insulation/sheath will not embrittle prematurely .
Environmental & chemical resistance. Suitable for dry to damp indoor locations; resistant to mild acids, alkalis, alcohols, and common cleaning agents at room temperature . It is not rated for immersion, continuous outdoor UV exposure, or direct burial — route outdoors through UV-protective conduit or select a UV-rated jacketed type. Expected indoor service life is 25+ years at ≤ 70 °C conductor temperature when properly derated.
4. Applications & Scope of Use
Primary applications
-
Power supply cords for household appliances: computers, TVs, audio systems, small refrigerators, washing machines, small power tools.
-
Lighting connections: ceiling LED strips, wall-mounted luminaires, suspended/pendant light fittings.
-
Control & signal transmission: instruments, meters, automation equipment, sensors, indicators, relays.
-
Security & smart building: CCTV camera power, access control / door-entry systems, alarm hosts, smart switches, weak-current cabinets.
-
OEM & control panels: internal wiring of distribution boards, consumer units, and switchgear; equipment power entry leads.
-
Temporary indoor wiring and test-instrument connections.
Typical projects: apartments and villas · commercial office fit-outs · retail stores, restaurants, hotels · light industrial workshops and laboratories · security / building-automation installations.
Use limitations: not for direct burial, not for prolonged outdoor sun exposure, not for fire-rated emergency circuits (use NH-RVV or WDZ-RVV for fire-resistant / LSZH requirements).
5. Installation & Handling
|
Aspect |
Recommendation |
|---|---|
|
Installation method |
Conduit, trunking, cable tray (covered), inside switchgear / distribution boards, appliance internal wiring |
|
Termination |
Screw terminals (tinned strand ends or bootlace ferrule recommended), crimp lugs; strip insulation 8–10 mm |
|
Pulling tension (max) |
Keep axial pull moderate; use pulling lubricant for long conduit runs to avoid sheath drag damage |
|
Min. bend radius |
≥ 4 × overall diameter (~23–29 mm) |
|
Low-temp handling |
Below 0 °C, warm cable before bending/pulling to avoid insulation cracking |
|
Conduit fill |
Do not exceed ~40% conduit cross-sectional fill for multi-circuit groups to control heat buildup |
|
Pre-energization check |
Continuity + insulation resistance (≥ 1 MΩ at 500 V DC megger) on every circuit before applying power |
|
Storage |
Cool, dry location; avoid direct sun and stacking heavy reels on top |
6. Selection Guide (RVV family reference)
|
If your project requires… |
Recommended alternative |
|---|---|
|
Larger current / lower voltage drop |
RVV 2×1.0 / 2×1.5 / 2×2.5 mm² (32/0.20, 48/0.20, 49–51/0.25; thicker CSA) |
|
3-core with protective earth |
RVV 3×0.75 mm² (24/0.20, 0.6/0.8 mm insulation/sheath) |
|
Fire-resistant circuit integrity |
NH-RVV (fire-resistant PVC) |
|
Low-smoke, zero-halogen (public buildings) |
WDZ-RVV (LSZH sheathed) |
|
90 °C operating temperature |
RVV-90 (PVC/E insulation + PVC/ST10 sheath) |
|
Shielded (anti-interference) |
RVVP (PVC-insulated, PVC-sheathed shielded flexible cord) |
|
Outdoor / UV / direct burial |
Use UV-rated jacketed or armored cable (RVV is indoor/damp-rated only) |
7. Quality Assurance
Every production batch is inspected per GB/T 5023.5-2008 / IEC 60227-5, covering: conductor resistance (4-wire Kelvin), strand count & lay length, insulation & sheath thickness / concentricity, high-voltage spark or immersion test (2000 V AC), flame-retardancy sampling (GB/T 18380.12), PVC tensile/elongation and aging verification, plus dimensional and visual inspection. Certificate of Compliance (CoC) and test reports are available on request, referenced to batch number and manufacturing date.