RVV 4 Core Flexible Control Cable 4x0.75mm2 Stranded Copper Conductor PVC Insulated
RVV-4*0.75mm² Premium RVV 4 Core Control Cable Stranded Copper Conductor PVC Insulated,Outer Sheathed
RVV 4×0.75 mm² Copper Conductor PVC Insulated & Sheathed Flexible Cord
Type: 60227 IEC 53 (RVV) · Voltage: 300/500 V · Standard: GB/T 5023.5-2008 / IEC 60227-5:2003 · Certification: CCC · Origin: Anhui, China
Cable Photo Show
1. Electrical & Structural Parameters
|
Category |
Parameter |
Value / Description |
|---|---|---|
|
Identification |
Type / Model |
60227 IEC 53 (RVV) — copper-core PVC-insulated PVC-sheathed flexible cord, 4-core |
|
Common Name |
Light-duty PVC sheathed 4-core flexible cord ("4-wire soft sheathed cable") |
|
|
Number of Cores × Nominal CSA |
4 × 0.75 mm² (3 Phase / Line + 1 Protective Earth, or L1+L2+N+PE per application) |
|
|
Conductor |
Conductor Material |
Annealed bare copper (Class 5 flexible, per GB/T 3956 / IEC 60228) |
|
Conductor Construction (each core) |
24 / 0.20 mm (24 fine strands of 0.20 mm diameter) |
|
|
Conductor Shape |
Circular, stranded flexible |
|
|
Max. DC Resistance @ 20 °C (each core) |
≤ 26.0 Ω/km |
|
|
Insulation |
Insulation Material |
PVC/D type polyvinyl chloride compound |
|
Insulation Nominal Thickness (each core) |
0.6 mm |
|
|
Insulation Min. Thickness (thin point) |
≥ 0.4 mm |
|
|
Finished Core Outer Diameter (each) |
≈ 2.35 ± 0.15 mm |
|
|
Sheath |
Sheath Material |
PVC/ST5 type polyvinyl chloride compound |
|
Sheath Nominal Thickness |
0.9 mm |
|
|
Sheath Min. Thickness (thin point) |
≥ 0.7 mm |
|
|
Dimensions |
Avg. Overall Diameter (round, 4-core bundled) |
7.6 mm (lower) ~ 9.4 mm (upper) |
|
Avg. Overall Diameter (flat, 4-core in-line) |
≈ 3.7 × 10.2 mm (lower) ~ 4.5 × 12.0 mm (upper) |
|
|
Reference Overall Diameter |
≈ 8.2 mm (round, typical) |
|
|
Approx. Weight |
72 ~ 88 kg/km (typical ≈ 80 kg/km) |
|
|
Electrical |
Rated Voltage (U₀/U) |
300/500 V (AC) |
|
Dielectric Withstand Test |
2000 V AC, 5 min, no breakdown |
|
|
Min. Insulation Resistance @ 70 °C |
≥ 0.011 MΩ·km |
|
|
Min. Insulation Resistance @ 20 °C |
≥ 20 MΩ·km |
|
|
Earth Continuity Resistance |
≤ 26.0 Ω/km (same as phase conductors) |
|
|
Temperature |
Max. Continuous Conductor Temp. |
70 °C |
|
Short-Circuit Temp. (≤ 5 s) |
150 °C |
|
|
Min. Installation / Laying Temp. |
0 °C (warm cable if below; some compounds allow −15 °C) |
|
|
Mechanical |
Min. Bending Radius |
4 × overall diameter (cable OD < 25 mm) ≈ 30 ~ 38 mm |
|
Flame Retardant |
Passes GB/T 18380.12-2020 (IEC 60332-1), self-extinguishing |
|
|
IP Level |
IP40 (dust-protected; mechanical protection depends on conduit/trunking) |
|
|
Physical Properties (PVC, before aging) |
Tensile strength ≥ 10.0 N/mm²; elongation at break ≥ 150% |
|
|
Aging (80±2 °C × 168 h) |
Tensile / elongation change rate within ±20% |
|
|
Color |
Core Colors (standard IEC, 3P+E) |
Brown + Black + Grey (L1/L2/L3) + Green/Yellow (PE) |
|
Core Colors (L+N+L2+PE, alternative) |
Brown (L) + Blue (N) + Black (L2) + Green/Yellow (PE) |
|
|
Custom Core Colors |
Red/White/Yellow/Green-Yellow; custom coding available |
|
|
Sheath Color |
Black (standard); White, Grey, Orange on request |
|
|
Packing |
Standard Length |
100 m / 200 m / 500 m per roll (custom lengths available) |
2. Current-Carrying Capacity Reference
|
Installation Condition |
Reference Ampacity* |
Notes |
|---|---|---|
|
4-core, single cable in free air (25 °C ambient) |
5 ~ 8 A (typical ≈ 7.5 A) |
Per IEC 60227-5 tabulated value ≈ 7–8 A (single, 20 °C conductor) |
|
4-core, bundled / in conduit (25 °C) |
≈ 6 A |
Apply ~20% derating for 4-core grouping |
|
With ambient 30 °C |
≈ 6.8 A |
×0.91 temperature correction |
|
With ambient 40 °C |
≈ 6.2 A |
×0.82 temperature correction |
|
With ambient 50 °C |
≈ 5.6 A |
×0.71 temperature correction |
* Reference values for PVC-insulated copper conductor at 70 °C temp. class; actual ampacity must be corrected for ambient temperature, grouping/bundling, conduit fill, and local wiring regulations. Do not use the uncorrected free-air value for enclosed/conduit installations.
Derived electrical reference (4×0.75 mm², 25 m four-wire run — 3-phase 400 V or 2-phase+PE 220 V)
|
Quantity |
Calculated Value |
Interpretation |
|---|---|---|
|
Voltage drop @ 7.5 A, 3-phase 400 V, 25 m (L-L loop) |
≈ 9.8 V (2.4% of 400 V) |
Well within 3% tolerance for 3-phase distribution |
|
Voltage drop @ 7.5 A, single-phase 220 V, 25 m (L+N loop) |
≈ 9.8 V (4.4% of 220 V) |
Within typical tolerance |
|
Usable 3-phase power @ 7.5 A, 400 V |
≈ 5.2 kVA (≈ 4.7 kW at pf=0.9) |
Suitable for small 3-phase motors, distribution sub-feeds |
|
Usable single-phase power @ 7.5 A, 220 V |
≈ 1.65 kW |
Adequate for lighting panels, small appliance groups |
|
PE conductor continuity check |
≤ 26.0 Ω/km |
Confirms earth-fault loop impedance for protective device coordination |
3. Product Performance Introduction
The RVV 4×0.75 mm² is a compact 4-core flexible cord engineered for three-phase distribution, dual-circuit control, and multi-signal transmission within a single sheathed assembly. It houses four Class 5 fine-strand annealed copper conductors (24/0.20 mm each), each individually insulated in PVC/D compound (0.6 mm) and collectively enclosed in a PVC/ST5 outer sheath (0.9 mm). The 4-core bundled layup produces a round cross-section of approximately 7.6–9.4 mm overall diameter, balancing flexibility with the mechanical robustness needed for multi-conductor routing .
4-core architecture advantage. Unlike 2- or 3-core versions, the 4-core configuration supports 3-phase + PE distribution (Brown/Black/Grey + Green-Yellow per IEC 60446) or 2-phase + Neutral + PE (Brown/Black + Blue + Green-Yellow) in a single cable. This eliminates the need to run multiple 2-core cables in parallel, reducing conduit fill, installation time, and the risk of mismatched phase/earth pairings. The unified sheath also provides a cleaner aesthetic and better strain relief at entry points .
Electrical performance under 4-core loading. With a 2000 V AC / 5 min withstand proof test and ≥ 0.011 MΩ·km insulation resistance at 70 °C, the cable maintains dielectric isolation even when all four cores are simultaneously energized . The ≤ 26.0 Ω/km DC resistance per core ensures balanced voltage drop across all conductors: at the reference 7.5 A rating over a 25 m three-phase run, the line-to-line voltage drop is ~9.8 V (2.4% of 400 V) — well within the 3% statutory limit for distribution circuits . For single-phase use (L+N loop), the drop is ~9.8 V (4.4% of 220 V), also compliant with typical building wiring tolerances.
Thermal management in 4-core bundles. The addition of a fourth core increases mutual heating when all conductors carry current simultaneously. Reference free-air ampacity therefore steps down from ~9 A (3-core) to ~7.5 A (4-core) . The PVC/D + PVC/ST5 system remains stable at 70 °C continuous with a 150 °C short-circuit withstand (5 s max), making it suitable for indoor distribution where ambient rarely exceeds 40 °C. The outer sheath thickness increases to 0.9 mm (vs. 0.8 mm for 2/3-core) to maintain crush resistance despite the larger core bundle .
Mechanical & safety profile. The fine-strand construction allows the 4-core cable to be pulled through conduit and dressed into panels while maintaining a minimum bend radius of 4× overall diameter (~30–38 mm) . The 0.9 mm sheath provides enhanced abrasion resistance during installation pulls and protects against minor crushing in trunking. Flame retardancy per GB/T 18380.12 (IEC 60332-1) ensures self-extinguishing behavior, limiting fire propagation along the cable route . Pre- and post-aging PVC properties (tensile ≥10.0 N/mm², elongation ≥150%, change within ±20% after 168 h at 80 °C) confirm the sheath will not embrittle over decades of service .
Installation efficiency. Running a single 4-core cable instead of two 2-core cables reduces the number of terminations, eliminates conductor-cross-talk from parallel runs, and simplifies circuit identification through consistent color coding. For projects requiring custom core identification, the manufacturer supports non-standard color combinations without affecting electrical certification.
4. Specification Range
5. Applications & Scope of Use
Primary applications
-
Small 3-phase distribution: 3-phase motors ≤ 1.5 kW (fans, pumps, compressors), 3-phase LED drivers, 3-phase inverter feeds.
-
Dual-circuit power: Two independent single-phase loads powered from one sheath (e.g., left/right lighting banks, paired socket groups).
-
Building automation multi-drop: HVAC damper actuators, VAV boxes, fan coil units with 3-speed + earth control.
-
Security & access (multi-device): Electric strike + magnetic lock + request-to-exit sensor + common earth on one 4-core run.
-
CCTV + power combo: Camera video/power + heater + earth in a single cable (where separate data cable is not required).
-
Control panels: 3-phase contactor coils, thermal overloads, pilot lights, and auxiliary contacts — all wired from one 4-core entry.
-
Stage & event lighting: 3-phase dimmer pack feeds, truss-mounted fixture groups (low-power).
-
OEM equipment: 3-phase internal distribution within machinery, robotic cells, conveyor systems.
-
Smart building: KNX/DALI power + data combos, multi-button switch panels with common return.
Typical projects: small commercial 3-phase fit-outs · residential with 3-phase service · light industrial automation · HVAC installations · security system multi-device wiring · stage/event production · OEM machinery manufacturing.
Use limitations: not for direct burial · not for prolonged outdoor UV exposure · not for fire-rated emergency circuits (use NH-RVV or WDZ-RVV for fire-resistant / LSZH) · not for high-power 3-phase loads >5 kW on a single run (upsize to 1.0 / 1.5 / 2.5 mm²).
6. Installation & Handling
|
Aspect |
Recommendation |
|---|---|
|
Installation method |
Conduit, trunking, cable tray (covered), inside switchgear / distribution boards, appliance internal wiring |
|
Phase identification |
Verify core colors before termination: Brown/Black/Grey = L1/L2/L3; Green/Yellow = PE. Re-mark if local code differs. |
|
Earth conductor termination |
Always connect PE core first; verify continuity ≤ 26 Ω/km before energizing any phase |
|
Termination of fine strands |
Bootlace ferrules (DIN 46228, 0.75 mm² / 8 mm barrel) or pre-tin all 4 cores before screw-terminal clamping |
|
Pulling tension (max) |
≤ 200 N axial pull; use lubricant for conduit runs >15 m to prevent sheath drag and oval distortion |
|
Min. bend radius |
≥ 4 × overall diameter (~30–38 mm); avoid sharp bends that flatten the round profile into an oval |
|
Low-temp handling |
Below 0 °C, warm cable to ≥5 °C before bending/pulling to prevent sheath cracking |
|
Conduit fill (4-core) |
4-core occupies ~2× the cross-sectional area of 2-core; do not exceed 35% conduit fill for multi-circuit groups |
|
Pre-energization check |
Continuity on all 4 cores + insulation resistance (≥1 MΩ at 500 V DC megger) L1-E, L2-E, L3-E, L1-L2, L1-L3, L2-L3 before applying power |
|
Storage |
Cool, dry location; avoid direct sun; do not stack heavy reels on top of 0.75 mm² rolls |
7. Selection Guide (RVV 4-core family & alternatives)
|
If your project requires… |
Recommended alternative |
|---|---|
|
Larger current / lower voltage drop |
RVV 4×1.0 / 4×1.5 / 4×2.5 mm² (32/0.20, 48/0.20, 49–51/0.25; thicker CSA) |
|
3-core only (no 4th conductor) |
RVV 3×0.75 mm² (Brown/Blue/Green-Yellow) |
|
5-core for 3-phase + N + PE |
RVV 5×0.75 mm² (Brown/Black/Grey + Blue + Green-Yellow) |
|
Fire-resistant circuit integrity |
NH-RVV 4×0.75 mm² (mica-tape fire barrier under insulation) |
|
Low-smoke, zero-halogen (public buildings) |
WDZ-RVV 4×0.75 mm² (LSZH sheath compound) |
|
Shielded (EMC / signal integrity) |
RVVP 4×0.75 mm² (aluminum foil + drain wire shield) |
|
90 °C operating temperature |
RVV-90 4×0.75 mm² (PVC/E insulation + PVC/ST10 sheath) |
|
Outdoor / UV / direct burial |
Use UV-rated jacketed or armored cable (standard RVV is indoor/damp-rated only) |
|
Flat-profile for surface mount |
Request flat 4-core layup (≈ 3.7×12.0 mm) |
8. Quality Assurance
Every production batch is inspected per GB/T 5023.5-2008 / IEC 60227-5, covering: conductor resistance (4-wire Kelvin, all 4 cores), strand count & lay length, insulation & sheath thickness / concentricity, high-voltage spark or immersion test (2000 V AC, 100% length), flame-retardancy sampling (GB/T 18380.12), PVC tensile/elongation and aging verification (80±2 °C × 168 h), plus dimensional and visual inspection including core color verification. Certificate of Compliance (CoC) and test reports are available on request, referenced to batch number and manufacturing date.