Heating and Cooling Heat Pump
25kw 30kw 35kw 47kw 60kw COP Air Source Heat Pump Systems For Commercial
25kw 30kw 35kw 47kw 60kw COP Air Source Heat Pump Systems For Commercial Description of Power World Air Source Heat Exchanger (house warming and air cooling): 1. Strong SGCC Casing Dark Cyan Charming Design; 2. Smart control double systems; 3. Danfoss/Copeland/Emerson/Eaton etc. precise accessories are constructing outstanding quality & high efficient performance. 4. Excellent for both hot water, heating & cooling, meeting all demands you need.. Product Description: economy:
128kw Commercial use EVI low temperature heat pump for green house heating
81.2 KW EVI Low Ambient Air To Water Heat Pump for heating cooling and hot water Specifications: Parameters MG-200KFLW Body size(W*D*H) MM 2000*1100*2080 Compressor Copeland Refrigerant R407C Power supply 380V/50Hz Condenser shell and coil Thermostatic expansion valve Danfoss AC contactor (220V-38A)*2 Controller Dual system Low-voltage switch 0.05/0.15MPa High-voltage switch 3.0/3.6MPa Power line connect with unit 3*10mm2+2*4mm2 20℃ Heating capacity (kW) 81.2 Input power (kW)
7.8KW High COP Low Temperature Heat Pump For Hot Water and Cooling and Heating
7.8KW High COP Low Temperature Heat Pump For Hot Water and Cooling and Heating Specifications: Model No. MG-020-KFXRS Heating Capacity(kW) 7.8 Heating Input Power(kW) 1.78 COP(Coefficient of Performance) 4.38 Voltage 220V/50Hz Rated Current(A) 14 Advised cable 3*2.5mm2 IP Grade (Level of protection) I Level of protection IPX4 Working Condition(℃) -25 to 43 Rated Water Temp.(℃) 55 Max Water Temp.(℃) 60 Hot Water Capacity(L/H) 112 Water Connection Size(mm) DN25 Compressor
12 KW High COP low temperature Heat Pump For Hot Water and Cooling and Heating
12 KW High COP low temperature Heat Pump For Hot Water and Cooling and Heating Specifications: Model No. MG-030KFXRS Heating Capacity(kW) 12 Heating Input Power(kW) 2.78 COP(Coefficient of Performance) 4.32 Voltage 380V/50Hz Rated Current(A) 7.5 Advised cable 3*2.5mm2+2*1.5mm2 IP Grade (Level of protection) I Level of protection IPX4 Working Condition(℃) -25 to 43 Rated Water Temp.(℃) 55 Max Water Temp.(℃) 60 Hot Water Capacity(L/H) 172 Water Connection Size(mm) DN25
81.2 KW Low Ambient Air To Water Heat Pump for heating cooling and hot water
81.2 KW Low Ambient Air To Water Heat Pump for heating cooling and hot water Specifications: Parameters MG-200KFLW Body size(W*D*H) MM 2000*1100*2080 Compressor Copeland Refrigerant R407C Power supply 380V/50Hz Condenser shell and coil Thermostatic expansion valve Danfoss AC contactor (220V-38A)*2 Controller Dual system Low-voltage switch 0.05/0.15MPa High-voltage switch 3.0/3.6MPa Power line connect with unit 3*10mm2+2*4mm2 20℃ Heating capacity (kW) 81.2 Input power (kW) 21
MG-050KFLW EVI low temperature air source heat pump for hot water, cooling and heating, 1110*490*1260
MG-050KFLW EVI low temperature air source heat pump Product model MG-050KFLW Body size(W*D*H) MM 1110*490*1260 Compressor Copeland Refrigerant R407C Power supply 380V/50Hz Condenser Efficient tank Thermostatic expansion valve Danfoss AC contactor (220V-18A) Controller Dual system Low-voltage switch 0.05/0.15MPa High-voltage switch 3.0/3.6MPa Power line connect with unit 3*4mm2+2*2.5mm2 20℃ Heating capacity (kW) 20.6 Input power (kW) 5.4 Rated current (A) 9 COP 3.81
Power World popular 38kw air to air heating cooling heatpump for Europe market
Copeland 13.6kw 220v / 50hz Air Cooled Chillers Low Pressure Protection Heating And Cooling Heat Pumps Parameters: Product model PF030-KFXLN-S PF030-KFXLN PF045-KFXLN-S PF050-KFXLN PF060-KFXLN Parameters Cooling Cooling capacity(kW) 6.4 7.6 11 12.6 14.5 Cooling input power(kW) 2.1 2.6 3.7 4.2 4.9 Rated current (A) 10.3 4.6 5.6 7.3 8.1 EER 3.05 2.92 2.97 3.00 2.96 Heating* Heating capacity (kW) 8.1 9.1 13.6 15.1 17.6 Heating input power(kW) 2.4 2.7 4.1 4.4 5.2 Rated current (A
Efficiency Reliability Commercial heat pump chiller for heating and cooling
30kw Heating And Cooling Heat Pumps With Dual System Controller Heating And Cooling Heat Pumps Parameters: Product Model PF100-KFXLN-U PF100-KFXLN-V PF120- KFXLN PF150- KFXLN PF200- KFXLN Parame -ters Cooling Cooling capacity(kW) 25.1 25.1 30.1 35.2 47.3 Cooling input power(kW) 8.4 8.4 10.3 12.1 16 Rated current (A) 14.5 14.5 17.8 21 27.7 EER 2.99 2.99 2.92 2.91 2.96 Heating Heating capacity(kW) 30.3 30.3 36.2 42.6 57.2 Heating input power(kW) 8.8 8.8 10.6 12.5 16.8 Rated
Commercial use air heating cooling heat pump
380v / 50hz Galvanized Steel 85kw Heating And Cooling Heat Pumps With Four Way Valve Heating And Cooling Heat Pumps Parameters: Product Model PF150-KFXLN PF200-KFXLN PF250-KFXLN PF300-KFXLN Parame -ters Cooling Cooling capacity(kW) 35.2 47.3 60.2 70.1 Cooling input power(kW) 12.1 16 20.5 23.8 Rated current (A) 21 27.7 35.5 41.2 EER 2.91 2.96 2.94 2.95 Heating Heating capacity(kW) 42.6 57.2 72.5 84.5 Heating input power(kW) 12.5 16.8 21.5 25.1 Rated current (A) 21.6 29.1 37.1
Monobloc copeland scroll copeland compressor air to air heat pump chiller
15.1Kw Air to water heat pump for Heating And Cooling COP 4.0 With Galvanized Steel Cabinet Models PF050-KFXLN Heating capacity kW 15.1 Heating nput power kW 4.4 Rated heating current A 7.5 COP 3.43 Cooling capacity kW 12.6 Cooling input power kW 4.2 Rated cooling current A 7.3 EER 3.00 Power supply kW 380V/50Hz/3Ph Rated/Max output temp ℃ 45/60 water flow L/H 3232 Diameter of pipe DN25 Compressor Copeland ZW61KAE Refrigerant R407C Evaporator L-2/990*1200/φ9.52 Condenser Tube
Automatic Control Agriculture Green House Tomato Greenhouse Heating heat pump
30kw ~ 85kw Commercial heat pump water heater, calentador de agua de bomba de calor comercial 380V/60Hz Description of Power World Air Source Heat Exchanger (house warming and air cooling): 1. Galvanized stainless steel frame and base; 2. Intelligent system control; complete protection, 3.Copeland compressor, Danfoss/Emerson expansion valve/Eaton AC contactor ==high efficient performance. Applications: Business Organizations supermarket, large-scale shopping malls, exclusive
High quality system reversible heat pump for heating or cooling
30kw Air Source Heat Pump R407C refrigerant with function of Air Conditioning And Space Heating Air source heat pump for heating and cooling Description 1. Heat pump with heating and cooling two function in one; 2.Good Case material:Galvanized steel with powder painted; 3.Eco-friendly refrigerant:R407C; 4.Best quality components: Copeland compressor, Emerson/Danfoss expasion valve, Schneider switch, etc; 5.High Level of protection:(Level of protection) IPX4; 6. High efficient
15.1kw Air To Water Heat Pump For Heating And Cooling COP 4.0 With Galvanized Steel Cabinet
15.1Kw Air to water heat pump for Heating And Cooling COP 4.0 With Galvanized Steel Cabinet Models PF050-KFXLN Heating capacity kW 15.1 Heating nput power kW 4.4 Rated heating current A 7.5 COP 3.43 Cooling capacity kW 12.6 Cooling input power kW 4.2 Rated cooling current A 7.3 EER 3.00 Power supply kW 380V/50Hz/3Ph Rated/Max output temp ℃ 45/60 water flow L/H 3232 Diameter of pipe DN25 Compressor Copeland ZW61KAE Refrigerant R407C Evaporator L-2/990*1200/φ9.52 Condenser Tube
30kw Heating And Cooling Heat Pumps With Dual System Controller
30kw Heating And Cooling Heat Pumps With Dual System Controller Heating And Cooling Heat Pumps Parameters: Product Model PF100-KFXLN-U PF100-KFXLN-V PF120- KFXLN PF150- KFXLN PF200- KFXLN Parame -ters Cooling Cooling capacity(kW) 25.1 25.1 30.1 35.2 47.3 Cooling input power(kW) 8.4 8.4 10.3 12.1 16 Rated current (A) 14.5 14.5 17.8 21 27.7 EER 2.99 2.99 2.92 2.91 2.96 Heating Heating capacity(kW) 30.3 30.3 36.2 42.6 57.2 Heating input power(kW) 8.8 8.8 10.6 12.5 16.8 Rated
Copeland 13.6kw 220v / 50hz Air Cooled Chillers Low Pressure Protection
Copeland 13.6kw 220v / 50hz Air Cooled Chillers Low Pressure Protection Heating And Cooling Heat Pumps Parameters: Product model PF030-KFXLN-S PF030-KFXLN PF045-KFXLN-S PF050-KFXLN PF060-KFXLN Parameters Cooling Cooling capacity(kW) 6.4 7.6 11 12.6 14.5 Cooling input power(kW) 2.1 2.6 3.7 4.2 4.9 Rated current (A) 10.3 4.6 5.6 7.3 8.1 EER 3.05 2.92 2.97 3.00 2.96 Heating* Heating capacity (kW) 8.1 9.1 13.6 15.1 17.6 Heating input power(kW) 2.4 2.7 4.1 4.4 5.2 Rated current (A
Renewable energy solutions air to water heat pump for home heating and cooling
Renewable energy solutions air to water heat pump for heating, cooling heat pump water chiller,water heater Description of Power World Air Source Heat Exchanger (house warming and air cooling): 1. Galvanized stainless steel frame and base; 2. Intelligent system control; complete protection, 3. Danfoss/Copeland/Emerson/Eaton etc. precise accessories are constructing outstanding quality & high efficient performance. Product Description: Economy: The operating cost is only 1/4
17.6Kw Stainless Steel Casing Heating and Cooling Heat Pump Danfoss Expansion Valve
17.6Kw Stainless Steel Casing Heating and Cooling Heat Pump Danfoss Expansion Valve Heating And Cooling Heat Pumps Parameters: Product model PF030-KFXLN-S PF030-KFXLN PF045-KFXLN-S PF050-KFXLN PF060-KFXLN Parameters Cooling Cooling capacity(kW) 6.4 7.6 11 12.6 14.5 Cooling input power(kW) 2.1 2.6 3.7 4.2 4.9 Rated current (A) 10.3 4.6 5.6 7.3 8.1 EER 3.05 2.92 2.97 3.00 2.96 Heating* Heating capacity(kW) 8.1 9.1 13.6 15.1 17.6 Heating input power(kW) 2.4 2.7 4.1 4.4 5.2 Rated
Stainless Steel Heating And Cooling Heat Pumps From 8.1kw - 75.6kw
Stainless Steel Heating And Cooling Heat Pumps From 8.1kw - 75.6kw Air Cooled Chillers Features: 1) Base frame and external panels are made of galvanized sheet. 2) High efficiency compressor with R407c Refrigerant. 3) Touch design LCD control panel, and the control signals are easier to be transferred to the control system; 4) Openable cabinet door design for faster and simpler checking and maintenance 5) Well heat insulation inside the unit to increase the COP. 6) Exterior
DC Inverter Air to Water Heat Pump With High Efficiency High COP
Newest Dc Inverter Air to Water Heat Pump With High Efficiency Specification of DC Inverter Heat Pumps D/C inverter air source heat pump (Heating&cooling mode, R410a) Model MG-030BP MG-050BP FOB SHENZHEN USD$ $1,750.00 $2,680.00 Standard components Cabinet/Color Anti-rusting Spray Coating Refrigerant R410A Power Supply 220V~240V/50Hz/1Ph 380V~415V/50Hz/3Ph Compressor Dual-rotary D/C Inverter Compressor Condenser High efficiency tube in shell heat exchanger Evaporator Blue
Emerson Expansion Valve Heating and Cooling Heat Pump With Stainless Steel Casing
Emerson Expansion Valve Heating and Cooling Heat Pump With Stainless Steel Casing Heating And Cooling Heat Pumps Parameters: Product model PF030-KFXLN-S PF030-KFXLN PF045-KFXLN-S PF050-KFXLN PF060-KFXLN Parameters Cooling Cooling capacity(kW) 6.4 7.6 11 12.6 14.5 Cooling input power(kW) 2.1 2.6 3.7 4.2 4.9 Rated current (A) 10.3 4.6 5.6 7.3 8.1 EER 3.05 2.92 2.97 3.00 2.96 Heating* Heating capacity(kW) 8.1 9.1 13.6 15.1 17.6 Heating input power(kW) 2.4 2.7 4.1 4.4 5.2 Rated